Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 17 of 17 for “"zero-sequence voltage"”.
-
Technologies of Cascaded H-Bridge Battery Energy Storage System
… to improve the grid’s frequency regulation and voltage regulation capabilities. The Cascaded H-bridge (CHB) topology of Power Conversion System (PCS) can connect low-voltage DC components directly to medium-voltage grid or even highvoltage grid, without a power transformer. Due to the high …
-
Low-Computation-Cost and Low-Complexity Pulse-Width Modulation for Multilevel Inverters
… switch stresses, lower instantaneous rate of voltage change, lower switching frequency, etc. Therefore, multilevel inverters have been used in various industrial applications, such as photovoltaic systems, wind power systems, electric vehicle chargers, industrial motor drives, etc. The …
-
Online battery electrochemical impedance spectroscopy using a neutral point clamped inverter
… (NPC) inverter. This is accomplished by applying zero-sequence voltage injection to the NPC control. Connecting the battery midpoint to the neutral point of the inverter results in a perturbation current flowing into the battery. The battery voltage and current are measured, and subsequent …
-
Stator Winding Fault Detection Techniques for Permanent Magnet Machine Drives
… sideband frequencies and high frequency voltage injection are investigated, which explore the different behaviours of resistive and inductive asymmetry at high frequency. The robustness against transient states is achieved by the signal processing in the designed circuit board. Finally, …
-
Cascaded Inverters for Grid-Connected Photovoltaic Systems
… which allows independent control of each dc-link voltage. A generalized nonactive power theory is applied to generate the reactive current reference. Within the inverter’s capability, the local consumption of reactive power is provided to realize power factor correction. Then, the modular cascaded …
-
Developing fault-tolerant control strategies for a five-phase permanent-magnet machine drive system
… phase currents, i.e. currents that do not sum to zero. This allows for better optimization of the machine torque after open-phase faults occur. The post-fault phase currents are often controlled using the field-oriented control (FOC) technique. However, all previously proposed FOC transformations …
-
Modular Multilevel Cascaded Flying Capacitor STATCOM for Balanced and Unbalanced Load Compensation
Voltage and current unbalance are major problems in distribution networks, particularly with the integration of distributed generation systems. One way of mitigating these issues is by injecting negative sequence current into the distribution network using a Static Synchronous Compensator (STATCOM) …
-
Control Strategies for Dual Inverter-fed Open-end Winding PM machines with Nonsinusoidal back EMFs
… to one dc source. However, considering the zero sequence voltage is clamped to zero because of the return path between the two inverters, zero sequence current circulates in the machine windings which increases losses and generates heat. Furthermore, most PMSMs generate harmonics in the back …
-
Βελτίωση της ικανότητας αδιάλειπτης λειτουργίας Α/Γ με μετατροπείς ισχύος σε σφάλματα δικτύων διανομής μέσω της χρήσης υπερπυκνωτών
… the ability of WTGs to ride-through faults and voltage sags, by employing supercapacitor ESS. Two types of variable speed wind turbines generators are examined; the direct driven full-converter generators and the doubly-fed induction generators (DFIGs) with partially rated power converter …
-
Protection of distribution networks with distributed generation
… Distributed Generation (DG) connected to low voltage distribution networks (DNs) is increasing in the electricity market day by day as this technology is not only becoming cheaper relative to other resources but is also environmentally friendly. However, along with these benefits, DG can also …
-
Advanced Stator Inter-Turn Fault Diagnosis Methods for Line-Connected Induction Motors
… different motor loadings and unbalanced supply voltage are also considered. Both FPM and TFC exhibit almost identical precision in detecting SITFs and assessing the fault severity. However, FPM can identify the faulty phase and be implemented online, while TFC is not able to detect faulty …
-
Open-Winding Permanent Magnet Synchronous Machines Under Demagnetization Faults
… enhanced fault tolerance, higher DC bus voltage utilization, control flexibility, and improved power quality. Among the three OW-PMSM topologies, common DC bus, isolated DC bus, and floating capacitor, the common DC bus topology provides superior fault tolerance, making it attractive for …
-
Μέθοδοι αποκεντρωμένου ελέγχου μικροδικτύου με ΑΠΕ για τη βελτίωση της λειτουργίας σε μόνιμη και μεταβατική κατάσταση
… reactive power, forming the frequency and the voltage of each node, with respect topermissible limits. This operation emulates the parallel operation of synchronousgenerators. However, the different R/X ratio of the connection lines affects the reactivepower sharing. For overcoming this …
-
Control, Analysis, and Design of SiC-Based High-Frequency Soft-Switching Three-Phase Inverter/Rectifier
… when it faces flawed grid conditions such as voltage drop and voltage rise. During abnormal grid conditions, delivering constant active power from the inverter to the grid is essential to avoid large voltage ripples on the dc side because it could trigger over-voltage protection or harm the …
-
Simulace zlomeného vodiče v distribuční síti za použití programu ATP-EMTP
Při zlomení nebo přetržení vodiče dojde k dopadu vodiče na zem. V izolovaných sítí dochází k zemnímu spojení. Pro detekci zemního spojení je nejčastěji používána metoda nulové složky napětí. Principem metody je součet napětí ve všech fází, v symetrické soustavě je součet roven nule. Cílem práce je …
-
Ανάλυση, σχεδιασμός και κατασκευή ηλεκτρικού κινητήριου συστήματος με σύγχρονο κινητήρα μονίμων μαγνητών: βάση ανάπτυξης ηλεκτροκίνητου οχήματος κυψελών καυσίμου
… based on back Electromagnetic Force (EMF) zero crossing points. It should be noticed that the proposed method is implemented for real time fault detection and identification. Moreover, the already published position sensorless commutation methods for BLDC motor drive systems have been …
-
Indikace zemních spojení na venkovních vedeních
Tato diplomová práce se zabývá indikací a lokalizací zemních spojení na venkovních vedeních. Zemní spojení je nejčastěji se vyskytující typ poruchy na venkovních vedeních vysokého napětí – tvoří zhruba 95% všech poruch a je problematické jej současnými metodami správně a včas indikovat, …