{"id":{"repo_id":"adelaide","oai_identifier":"oai:digital.library.adelaide.edu.au:11541.2/39663"},"canonical_url":"https://search.ndltd.org/etd/adelaide/oai:digital.library.adelaide.edu.au:11541.2/39663","repository":{"repo_id":"adelaide","name":"University of Adelaide","base_url":"https://digital.library.adelaide.edu.au/server/oai/request"},"display":{"title":"Examining the role of copper in electrofusion couplings : implication for PE100 pipe durability","abstract":"Polyethylene (PE) has been used increasingly in pipelines for moderate pressure and temperature applications due to its corrosion resistance, longevity, cost-effectiveness, and ease of installation. PE100, designed for a 50-year service life, withstands harsh conditions like high temperatures and UV exposure. The PE100 pipes are commonly joined using electrofusion couplers with copper resistance wires, raising concerns about copper's potential to catalyse oxidative reactions, leading to premature failure. This study assesses HDPE's thermal and UV degradation in pipelines, particularly examining copper's impact. Results reveal that research-grade HDPE is more susceptible to copper-catalysed degradation than commercial PE100, although no significant oxidative degradation was detected at copper-containing electrofusion joints.","abstract_html":"Polyethylene (PE) has been used increasingly in pipelines for moderate pressure and temperature applications due to its corrosion resistance, longevity, cost-effectiveness, and ease of installation. PE100, designed for a 50-year service life, withstands harsh conditions like high temperatures and UV exposure. The PE100 pipes are commonly joined using electrofusion couplers with copper resistance wires, raising concerns about copper&#x27;s potential to catalyse oxidative reactions, leading to premature failure. This study assesses HDPE&#x27;s thermal and UV degradation in pipelines, particularly examining copper&#x27;s impact. Results reveal that research-grade HDPE is more susceptible to copper-catalysed degradation than commercial PE100, although no significant oxidative degradation was detected at copper-containing electrofusion joints.","abstract_has_math":false,"creators":["Chen, Ting Chong"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":"University of South Australia. UniSA STEM.","contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T14:05:01Z","subjects":["PE100;copper-catalysed oxidation;HDPE pipe","Copper","Pipe, Plastic","Polyethylene."],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11541.2/39663","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11541.2/39663","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aadelaide%3Aoai%3Adigital.library.adelaide.edu.au%3A11541.2%2F39663","prefix":"oai_dc"},"source_record":{"url":"https://digital.library.adelaide.edu.au/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.library.adelaide.edu.au%3A11541.2%2F39663","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.school","label":"School","values":["University of South Australia. UniSA STEM.","UniSA STEM"]},{"key":"dc:creator","label":"Author","values":["Chen, Ting Chong"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["PE100;copper-catalysed oxidation;HDPE pipe"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Copper","Pipe, Plastic","Polyethylene."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11541.2/39663"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["1 ethesis (xvii, 121 pages) :","illustrations (some colour), colour photographs.","Includes bibliographical references (pages 112-121)"]},{"key":"dc:description.abstract","label":"Abstract","values":["Polyethylene (PE) has been used increasingly in pipelines for moderate pressure and temperature applications due to its corrosion resistance, longevity, cost-effectiveness, and ease of installation. PE100, designed for a 50-year service life, withstands harsh conditions like high temperatures and UV exposure. The PE100 pipes are commonly joined using electrofusion couplers with copper resistance wires, raising concerns about copper's potential to catalyse oxidative reactions, leading to premature failure. This study assesses HDPE's thermal and UV degradation in pipelines, particularly examining copper's impact. Results reveal that research-grade HDPE is more susceptible to copper-catalysed degradation than commercial PE100, although no significant oxidative degradation was detected at copper-containing electrofusion joints."]},{"key":"dc:description.dissertation","label":"Dc Description Dissertation","values":["Thesis (PhD(Energy and Advanced Manufacturing))--University of South Australia, 2023."]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["Copyright 2023 Ting Chong Chen"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["506 0#$fstar $2Unrestricted online access"]},{"key":"dc:title","label":"Title","values":["Examining the role of copper in electrofusion couplings : implication for PE100 pipe durability"]}]}],"canonical_facts":{"dc:contributor.school":["University of South Australia. UniSA STEM.","UniSA STEM"],"dc:creator":["Chen, Ting Chong"],"dc:date.issued":["2023"],"dc:description":["1 ethesis (xvii, 121 pages) :","illustrations (some colour), colour photographs.","Includes bibliographical references (pages 112-121)"],"dc:description.abstract":["Polyethylene (PE) has been used increasingly in pipelines for moderate pressure and temperature applications due to its corrosion resistance, longevity, cost-effectiveness, and ease of installation. PE100, designed for a 50-year service life, withstands harsh conditions like high temperatures and UV exposure. The PE100 pipes are commonly joined using electrofusion couplers with copper resistance wires, raising concerns about copper's potential to catalyse oxidative reactions, leading to premature failure. This study assesses HDPE's thermal and UV degradation in pipelines, particularly examining copper's impact. Results reveal that research-grade HDPE is more susceptible to copper-catalysed degradation than commercial PE100, although no significant oxidative degradation was detected at copper-containing electrofusion joints."],"dc:description.dissertation":["Thesis (PhD(Energy and Advanced Manufacturing))--University of South Australia, 2023."],"dc:description.provenance":["Copyright 2023 Ting Chong Chen"],"dc:identifier.uri":["https://hdl.handle.net/11541.2/39663"],"dc:language.iso":["en"],"dc:subject":["PE100;copper-catalysed oxidation;HDPE pipe"],"dc:subject.lcsh":["Copper","Pipe, Plastic","Polyethylene."],"dcterms:accessrights":["506 0#$fstar $2Unrestricted online access"],"dc:title":["Examining the role of copper in electrofusion couplings : implication for PE100 pipe durability"],"dc:type":["thesis"]},"updated_at":"2026-11-19T14:05:01Z"}