{"id":{"repo_id":"adelaide","oai_identifier":"oai:digital.library.adelaide.edu.au:11541.2/39737"},"canonical_url":"https://search.ndltd.org/etd/adelaide/oai:digital.library.adelaide.edu.au:11541.2/39737","repository":{"repo_id":"adelaide","name":"University of Adelaide","base_url":"https://digital.library.adelaide.edu.au/server/oai/request"},"display":{"title":"Development of fibre optic dosimetry for medical applications","abstract":"Radionuclide therapy uses radiopharmaceuticals to treat cancers. The radioisotopes emit ionising radiation, which deposits the dose and kills the cancer cells. The dose delivered to the patient is verified from the images taken after treatment. In-vivo dose measurement during the treatment is crucial for better patient outcomes. In this study, we opted for a fibre optic dosimeter (FOD) due to its real-time dose monitoring capability and availability in small sizes suitable for in-vivo applications. The fibre optic probe was designed using a ruby scintillator. It was chosen due to its narrow emission spectrum in the red region, which is suitable for removing unwanted stem signal, a significant drawback of FOD. We developed a ruby FOD system for real-time in-vivo dose measurements during beta-emitting radionuclide therapy, and the post-image-based dosimetry protocol was validated.","abstract_html":"Radionuclide therapy uses radiopharmaceuticals to treat cancers. The radioisotopes emit ionising radiation, which deposits the dose and kills the cancer cells. The dose delivered to the patient is verified from the images taken after treatment. In-vivo dose measurement during the treatment is crucial for better patient outcomes. In this study, we opted for a fibre optic dosimeter (FOD) due to its real-time dose monitoring capability and availability in small sizes suitable for in-vivo applications. The fibre optic probe was designed using a ruby scintillator. It was chosen due to its narrow emission spectrum in the red region, which is suitable for removing unwanted stem signal, a significant drawback of FOD. We developed a ruby FOD system for real-time in-vivo dose measurements during beta-emitting radionuclide therapy, and the post-image-based dosimetry protocol was validated.","abstract_has_math":false,"creators":["Birajdar, Shalee,"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":"University of South Australia. UniSA STEM.","contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T14:05:13Z","subjects":["radioluminescence;fibre optic dosimetry;selective internal radiation therapy;stem effect;in vivo dosimetry","Dosimeters","Radiation","Radiation dosimetry."],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11541.2/39737","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11541.2/39737","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aadelaide%3Aoai%3Adigital.library.adelaide.edu.au%3A11541.2%2F39737","prefix":"oai_dc"},"source_record":{"url":"https://digital.library.adelaide.edu.au/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.library.adelaide.edu.au%3A11541.2%2F39737","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.school","label":"School","values":["University of South Australia. UniSA STEM.","UniSA STEM"]},{"key":"dc:creator","label":"Author","values":["Birajdar, Shalee,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["radioluminescence;fibre optic dosimetry;selective internal radiation therapy;stem effect;in vivo dosimetry"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Dosimeters","Radiation","Radiation dosimetry."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11541.2/39737"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["1 ethesis (xii, 99 pages) :","illustrations (chiefly colour)","Includes bibliographical references (pages 77-87 )"]},{"key":"dc:description.abstract","label":"Abstract","values":["Radionuclide therapy uses radiopharmaceuticals to treat cancers. The radioisotopes emit ionising radiation, which deposits the dose and kills the cancer cells. The dose delivered to the patient is verified from the images taken after treatment. In-vivo dose measurement during the treatment is crucial for better patient outcomes. In this study, we opted for a fibre optic dosimeter (FOD) due to its real-time dose monitoring capability and availability in small sizes suitable for in-vivo applications. The fibre optic probe was designed using a ruby scintillator. It was chosen due to its narrow emission spectrum in the red region, which is suitable for removing unwanted stem signal, a significant drawback of FOD. We developed a ruby FOD system for real-time in-vivo dose measurements during beta-emitting radionuclide therapy, and the post-image-based dosimetry protocol was validated."]},{"key":"dc:description.dissertation","label":"Dc Description Dissertation","values":["Thesis (Masters by Research (Applied Physics))--University of South Australia, 2024."]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["Copyright 2024 Shalee Birajdar."]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["506 0#$fstar $2Unrestricted online access"]},{"key":"dc:title","label":"Title","values":["Development of fibre optic dosimetry for medical applications"]}]}],"canonical_facts":{"dc:contributor.school":["University of South Australia. UniSA STEM.","UniSA STEM"],"dc:creator":["Birajdar, Shalee,"],"dc:date.issued":["2024"],"dc:description":["1 ethesis (xii, 99 pages) :","illustrations (chiefly colour)","Includes bibliographical references (pages 77-87 )"],"dc:description.abstract":["Radionuclide therapy uses radiopharmaceuticals to treat cancers. The radioisotopes emit ionising radiation, which deposits the dose and kills the cancer cells. The dose delivered to the patient is verified from the images taken after treatment. In-vivo dose measurement during the treatment is crucial for better patient outcomes. In this study, we opted for a fibre optic dosimeter (FOD) due to its real-time dose monitoring capability and availability in small sizes suitable for in-vivo applications. The fibre optic probe was designed using a ruby scintillator. It was chosen due to its narrow emission spectrum in the red region, which is suitable for removing unwanted stem signal, a significant drawback of FOD. We developed a ruby FOD system for real-time in-vivo dose measurements during beta-emitting radionuclide therapy, and the post-image-based dosimetry protocol was validated."],"dc:description.dissertation":["Thesis (Masters by Research (Applied Physics))--University of South Australia, 2024."],"dc:description.provenance":["Copyright 2024 Shalee Birajdar."],"dc:identifier.uri":["https://hdl.handle.net/11541.2/39737"],"dc:language.iso":["en"],"dc:subject":["radioluminescence;fibre optic dosimetry;selective internal radiation therapy;stem effect;in vivo dosimetry"],"dc:subject.lcsh":["Dosimeters","Radiation","Radiation dosimetry."],"dcterms:accessrights":["506 0#$fstar $2Unrestricted online access"],"dc:title":["Development of fibre optic dosimetry for medical applications"],"dc:type":["thesis"]},"updated_at":"2026-11-19T14:05:13Z"}