{"id":{"repo_id":"adelaide","oai_identifier":"oai:digital.library.adelaide.edu.au:11541.2/41279"},"canonical_url":"https://search.ndltd.org/etd/adelaide/oai:digital.library.adelaide.edu.au:11541.2/41279","repository":{"repo_id":"adelaide","name":"University of Adelaide","base_url":"https://digital.library.adelaide.edu.au/server/oai/request"},"display":{"title":"Active thermal support of electric motors and generators using TEC (peltier effect) technology","abstract":"The majority of electric motors in use today are induction motors between 0.75kW to 375kW. A major challenge to design engineers is thermal management. The heat caused by losses is generated in the motor volume and conducted to the outer surface. A new untried technology - Thermoelectric Coolers (TEC - Peltier Device), a solid-state heat pump, was employed in set experiments to actively support the motors thermal management. A core sample and test motor were assembled for experimentation. Three cooling configurations were used employing heat sinks, heat pipes with fan cooled radiators, and water cooled heatsinks to ensure the results were independent of system configuration. In all cases it was found that the addition of the TEC to the cooling system would impact on the inner core temperatures by lowering or raising inner core temperatures dependent on the direction the heat was pumped.","abstract_html":"The majority of electric motors in use today are induction motors between 0.75kW to 375kW. A major challenge to design engineers is thermal management. The heat caused by losses is generated in the motor volume and conducted to the outer surface. A new untried technology - Thermoelectric Coolers (TEC - Peltier Device), a solid-state heat pump, was employed in set experiments to actively support the motors thermal management. A core sample and test motor were assembled for experimentation. Three cooling configurations were used employing heat sinks, heat pipes with fan cooled radiators, and water cooled heatsinks to ensure the results were independent of system configuration. In all cases it was found that the addition of the TEC to the cooling system would impact on the inner core temperatures by lowering or raising inner core temperatures dependent on the direction the heat was pumped.","abstract_has_math":false,"creators":["Lucas, Stephen"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":"University of South Australia. UniSA STEM.","contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T13:54:18Z","subjects":["Electrical Motors;TEC;Thermal Support","Electric motors.","Thermoelectric apparatus and appliances","Thermoelectric cooling."],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11541.2/41279","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11541.2/41279","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aadelaide%3Aoai%3Adigital.library.adelaide.edu.au%3A11541.2%2F41279","prefix":"oai_dc"},"source_record":{"url":"https://digital.library.adelaide.edu.au/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.library.adelaide.edu.au%3A11541.2%2F41279","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.school","label":"School","values":["University of South Australia. UniSA STEM.","UniSA STEM"]},{"key":"dc:creator","label":"Author","values":["Lucas, Stephen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Motors;TEC;Thermal Support"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Electric motors.","Thermoelectric apparatus and appliances","Thermoelectric cooling."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11541.2/41279"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["1 ethesis (xxvii, 206 pages) :","colour illustrations, colour charts.","Includes bibliographical references (pages 195-206)"]},{"key":"dc:description.abstract","label":"Abstract","values":["The majority of electric motors in use today are induction motors between 0.75kW to 375kW. A major challenge to design engineers is thermal management. The heat caused by losses is generated in the motor volume and conducted to the outer surface. A new untried technology - Thermoelectric Coolers (TEC - Peltier Device), a solid-state heat pump, was employed in set experiments to actively support the motors thermal management. A core sample and test motor were assembled for experimentation. Three cooling configurations were used employing heat sinks, heat pipes with fan cooled radiators, and water cooled heatsinks to ensure the results were independent of system configuration. In all cases it was found that the addition of the TEC to the cooling system would impact on the inner core temperatures by lowering or raising inner core temperatures dependent on the direction the heat was pumped."]},{"key":"dc:description.dissertation","label":"Dc Description Dissertation","values":["Thesis (PhD(Electrical and Information Engineering))--University of South Australia, 2024."]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["Copyright 2024 Stephen Lucas."]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["506 0#$fstar $2Unrestricted online access"]},{"key":"dc:title","label":"Title","values":["Active thermal support of electric motors and generators using TEC (peltier effect) technology"]}]}],"canonical_facts":{"dc:contributor.school":["University of South Australia. UniSA STEM.","UniSA STEM"],"dc:creator":["Lucas, Stephen"],"dc:date.issued":["2024"],"dc:description":["1 ethesis (xxvii, 206 pages) :","colour illustrations, colour charts.","Includes bibliographical references (pages 195-206)"],"dc:description.abstract":["The majority of electric motors in use today are induction motors between 0.75kW to 375kW. A major challenge to design engineers is thermal management. The heat caused by losses is generated in the motor volume and conducted to the outer surface. A new untried technology - Thermoelectric Coolers (TEC - Peltier Device), a solid-state heat pump, was employed in set experiments to actively support the motors thermal management. A core sample and test motor were assembled for experimentation. Three cooling configurations were used employing heat sinks, heat pipes with fan cooled radiators, and water cooled heatsinks to ensure the results were independent of system configuration. In all cases it was found that the addition of the TEC to the cooling system would impact on the inner core temperatures by lowering or raising inner core temperatures dependent on the direction the heat was pumped."],"dc:description.dissertation":["Thesis (PhD(Electrical and Information Engineering))--University of South Australia, 2024."],"dc:description.provenance":["Copyright 2024 Stephen Lucas."],"dc:identifier.uri":["https://hdl.handle.net/11541.2/41279"],"dc:language.iso":["en"],"dc:subject":["Electrical Motors;TEC;Thermal Support"],"dc:subject.lcsh":["Electric motors.","Thermoelectric apparatus and appliances","Thermoelectric cooling."],"dcterms:accessrights":["506 0#$fstar $2Unrestricted online access"],"dc:title":["Active thermal support of electric motors and generators using TEC (peltier effect) technology"],"dc:type":["thesis"]},"updated_at":"2026-11-19T13:54:18Z"}