{"id":{"repo_id":"adelaide","oai_identifier":"oai:digital.library.adelaide.edu.au:2440/100719"},"canonical_url":"https://search.ndltd.org/etd/adelaide/oai:digital.library.adelaide.edu.au:2440/100719","repository":{"repo_id":"adelaide","name":"University of Adelaide","base_url":"https://digital.library.adelaide.edu.au/server/oai/request"},"display":{"title":"Investigation of cryogenic Er:YAG lasers for gravitational wave interferometry","abstract":"High power, stable single frequency laser sources are required for gravitational wave interferometry. The next generation of interferometers may require laser sources in the 1.3-1.65 µm band for use with Si test masses and InGaAs photodetectors. We propose a high power cryogenic Er:YAG laser operating at 1.618 µm for this purpose, adapting existing knowledge about cryogenic Yb:YAG lasers developed at the University of Adelaide. To produce such a laser, further information is required about the viability of Er:YAG in high power, single frequency operation. In this thesis, I report this investigation of the spectroscopy of Er:YAG at room temperature and at cryogenic temperatures (≈ 77 K) and investigate a variety of wavelengths for diode pumping of an Er:YAG slab laser. Spectroscopy indicates that diode pumping for the 77 K laser slab will be most effective in the 1450-1480 nm absorption band, most specifically at the 1453 nm absorption peak. I describe methods for cooling a 1470 nm diode below 0 °C to pump this 1453 nm Er:YAG absorption. The cooled diode exhibits up to 9 % increase in slope effciency and improved beam divergence compared to room temperature operation. I then describe the construction and characterisation of CW Er:YAG lasers at both 300 K and 77 K, tuning the pump wavelength in the 1450-1480 nm band. At 300 K, I demonstrate an Er:YAG laser with 4.5 W output power when pumped with 30 W of diode power at 1468 nm, and just under 4 W of output power when pumped with 34Wof diode power at 1456 nm. Both lasers have a threshold of approximately 12 W incident pump power. The laser pumped at 1468 nm also demonstrates a greater slope effciency relative to incident pump power: 28 % compared to 20 % when pumped at 1456 nm. The development of a preliminary cryogenic Er:YAG laser is also reported. Despite sub-optimal mounting materials and geometries, we demonstrate a cryogenic laser with 5.5 W output power and approximately 6 W threshold under comparable pumping conditions to the 4.5 W 300 K laser pumped at 1468 nm. Unfortunately subsequent studies of the cryogenic slab laser are not comparable to the 300 K Er:YAG laser due to electrical damage to the diode that significantly reduced diode power and changed pumping conditions. Nevertheless, these results provide valuable information on the sensitivity of end-pumped cryogenic lasers to mounting conditions and pump focusing that are useful for a future high power design.","abstract_html":"High power, stable single frequency laser sources are required for gravitational wave interferometry. The next generation of interferometers may require laser sources in the 1.3-1.65 µm band for use with Si test masses and InGaAs photodetectors. We propose a high power cryogenic Er:YAG laser operating at 1.618 µm for this purpose, adapting existing knowledge about cryogenic Yb:YAG lasers developed at the University of Adelaide. To produce such a laser, further information is required about the viability of Er:YAG in high power, single frequency operation. In this thesis, I report this investigation of the spectroscopy of Er:YAG at room temperature and at cryogenic temperatures (≈ 77 K) and investigate a variety of wavelengths for diode pumping of an Er:YAG slab laser. Spectroscopy indicates that diode pumping for the 77 K laser slab will be most effective in the 1450-1480 nm absorption band, most specifically at the 1453 nm absorption peak. I describe methods for cooling a 1470 nm diode below 0 °C to pump this 1453 nm Er:YAG absorption. The cooled diode exhibits up to 9 % increase in slope effciency and improved beam divergence compared to room temperature operation. I then describe the construction and characterisation of CW Er:YAG lasers at both 300 K and 77 K, tuning the pump wavelength in the 1450-1480 nm band. At 300 K, I demonstrate an Er:YAG laser with 4.5 W output power when pumped with 30 W of diode power at 1468 nm, and just under 4 W of output power when pumped with 34Wof diode power at 1456 nm. Both lasers have a threshold of approximately 12 W incident pump power. The laser pumped at 1468 nm also demonstrates a greater slope effciency relative to incident pump power: 28 % compared to 20 % when pumped at 1456 nm. The development of a preliminary cryogenic Er:YAG laser is also reported. Despite sub-optimal mounting materials and geometries, we demonstrate a cryogenic laser with 5.5 W output power and approximately 6 W threshold under comparable pumping conditions to the 4.5 W 300 K laser pumped at 1468 nm. Unfortunately subsequent studies of the cryogenic slab laser are not comparable to the 300 K Er:YAG laser due to electrical damage to the diode that significantly reduced diode power and changed pumping conditions. Nevertheless, these results provide valuable information on the sensitivity of end-pumped cryogenic lasers to mounting conditions and pump focusing that are useful for a future high power design.","abstract_has_math":false,"creators":["Hollitt, Sophie Elizabeth"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":"School of Physical Sciences","contributors":[],"advisors":["Munch, Jesper","Veitch, Peter John"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-11-19T14:03:01Z","subjects":["lasers","Er:YAG","high power laser","cryogenic laser","laser diode","spectroscopy","infrared"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2440/100719","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2440/100719","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aadelaide%3Aoai%3Adigital.library.adelaide.edu.au%3A2440%2F100719","prefix":"oai_dc"},"source_record":{"url":"https://digital.library.adelaide.edu.au/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.library.adelaide.edu.au%3A2440%2F100719","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Munch, Jesper","Veitch, Peter John"]},{"key":"dc:contributor.school","label":"School","values":["School of Physical Sciences"]},{"key":"dc:creator","label":"Author","values":["Hollitt, Sophie Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2015"]},{"key":"dc:type","label":"Dc Type","values":["Theses"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["lasers","Er:YAG","high power laser","cryogenic laser","laser diode","spectroscopy","infrared"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/2440/100719"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["High power, stable single frequency laser sources are required for gravitational wave interferometry. The next generation of interferometers may require laser sources in the 1.3-1.65 µm band for use with Si test masses and InGaAs photodetectors. We propose a high power cryogenic Er:YAG laser operating at 1.618 µm for this purpose, adapting existing knowledge about cryogenic Yb:YAG lasers developed at the University of Adelaide. To produce such a laser, further information is required about the viability of Er:YAG in high power, single frequency operation. In this thesis, I report this investigation of the spectroscopy of Er:YAG at room temperature and at cryogenic temperatures (≈ 77 K) and investigate a variety of wavelengths for diode pumping of an Er:YAG slab laser. Spectroscopy indicates that diode pumping for the 77 K laser slab will be most effective in the 1450-1480 nm absorption band, most specifically at the 1453 nm absorption peak. I describe methods for cooling a 1470 nm diode below 0 °C to pump this 1453 nm Er:YAG absorption. The cooled diode exhibits up to 9 % increase in slope effciency and improved beam divergence compared to room temperature operation. I then describe the construction and characterisation of CW Er:YAG lasers at both 300 K and 77 K, tuning the pump wavelength in the 1450-1480 nm band. At 300 K, I demonstrate an Er:YAG laser with 4.5 W output power when pumped with 30 W of diode power at 1468 nm, and just under 4 W of output power when pumped with 34Wof diode power at 1456 nm. Both lasers have a threshold of approximately 12 W incident pump power. The laser pumped at 1468 nm also demonstrates a greater slope effciency relative to incident pump power: 28 % compared to 20 % when pumped at 1456 nm. The development of a preliminary cryogenic Er:YAG laser is also reported. Despite sub-optimal mounting materials and geometries, we demonstrate a cryogenic laser with 5.5 W output power and approximately 6 W threshold under comparable pumping conditions to the 4.5 W 300 K laser pumped at 1468 nm. Unfortunately subsequent studies of the cryogenic slab laser are not comparable to the 300 K Er:YAG laser due to electrical damage to the diode that significantly reduced diode power and changed pumping conditions. Nevertheless, these results provide valuable information on the sensitivity of end-pumped cryogenic lasers to mounting conditions and pump focusing that are useful for a future high power design."]},{"key":"dc:description.dissertation","label":"Dc Description Dissertation","values":["Thesis (M.Phil.) -- University of Adelaide, School of Physical Sciences, 2015."]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["This electronic version is made publicly available by the University of Adelaide in accordance with its open access policy for student theses. Copyright in this thesis remains with the author. This thesis may incorporate third party material which has been used by the author pursuant to Fair Dealing exceptions. If you are the owner of any included third party copyright material you wish to be removed from this electronic version, please complete the take down form located at: http://www.adelaide.edu.au/legals"]},{"key":"dc:title","label":"Title","values":["Investigation of cryogenic Er:YAG lasers for gravitational wave interferometry"]}]}],"canonical_facts":{"dc:contributor.advisor":["Munch, Jesper","Veitch, Peter John"],"dc:contributor.school":["School of Physical Sciences"],"dc:creator":["Hollitt, Sophie Elizabeth"],"dc:date.issued":["2015"],"dc:description.abstract":["High power, stable single frequency laser sources are required for gravitational wave interferometry. The next generation of interferometers may require laser sources in the 1.3-1.65 µm band for use with Si test masses and InGaAs photodetectors. We propose a high power cryogenic Er:YAG laser operating at 1.618 µm for this purpose, adapting existing knowledge about cryogenic Yb:YAG lasers developed at the University of Adelaide. To produce such a laser, further information is required about the viability of Er:YAG in high power, single frequency operation. In this thesis, I report this investigation of the spectroscopy of Er:YAG at room temperature and at cryogenic temperatures (≈ 77 K) and investigate a variety of wavelengths for diode pumping of an Er:YAG slab laser. Spectroscopy indicates that diode pumping for the 77 K laser slab will be most effective in the 1450-1480 nm absorption band, most specifically at the 1453 nm absorption peak. I describe methods for cooling a 1470 nm diode below 0 °C to pump this 1453 nm Er:YAG absorption. The cooled diode exhibits up to 9 % increase in slope effciency and improved beam divergence compared to room temperature operation. I then describe the construction and characterisation of CW Er:YAG lasers at both 300 K and 77 K, tuning the pump wavelength in the 1450-1480 nm band. At 300 K, I demonstrate an Er:YAG laser with 4.5 W output power when pumped with 30 W of diode power at 1468 nm, and just under 4 W of output power when pumped with 34Wof diode power at 1456 nm. Both lasers have a threshold of approximately 12 W incident pump power. The laser pumped at 1468 nm also demonstrates a greater slope effciency relative to incident pump power: 28 % compared to 20 % when pumped at 1456 nm. The development of a preliminary cryogenic Er:YAG laser is also reported. Despite sub-optimal mounting materials and geometries, we demonstrate a cryogenic laser with 5.5 W output power and approximately 6 W threshold under comparable pumping conditions to the 4.5 W 300 K laser pumped at 1468 nm. Unfortunately subsequent studies of the cryogenic slab laser are not comparable to the 300 K Er:YAG laser due to electrical damage to the diode that significantly reduced diode power and changed pumping conditions. Nevertheless, these results provide valuable information on the sensitivity of end-pumped cryogenic lasers to mounting conditions and pump focusing that are useful for a future high power design."],"dc:description.dissertation":["Thesis (M.Phil.) -- University of Adelaide, School of Physical Sciences, 2015."],"dc:description.provenance":["This electronic version is made publicly available by the University of Adelaide in accordance with its open access policy for student theses. Copyright in this thesis remains with the author. This thesis may incorporate third party material which has been used by the author pursuant to Fair Dealing exceptions. If you are the owner of any included third party copyright material you wish to be removed from this electronic version, please complete the take down form located at: http://www.adelaide.edu.au/legals"],"dc:identifier.uri":["http://hdl.handle.net/2440/100719"],"dc:subject":["lasers","Er:YAG","high power laser","cryogenic laser","laser diode","spectroscopy","infrared"],"dc:title":["Investigation of cryogenic Er:YAG lasers for gravitational wave interferometry"],"dc:type":["Theses"]},"updated_at":"2026-11-19T14:03:01Z"}