{"id":{"repo_id":"adelaide","oai_identifier":"oai:digital.library.adelaide.edu.au:2440/135246"},"canonical_url":"https://search.ndltd.org/etd/adelaide/oai:digital.library.adelaide.edu.au:2440/135246","repository":{"repo_id":"adelaide","name":"University of Adelaide","base_url":"https://digital.library.adelaide.edu.au/server/oai/request"},"display":{"title":"A Study of the Analytical and Diagnostic Potential of Fibre-Optic Surface Plasmon Resonance-Extraordinary Optical Transmission Biosensors","abstract":"A fibre-optic surface plasmon resonance-extraordinary optical transmission (SPR-EOT) biosensor is developed based on a conventional SPR biosensor, utilising optical fibres and extraordinary optical transmission to miniaturise the biosensor for point-of-care diagnosis and real-time online analysis. The SPR biosensor is a well-established biosensing platform based on surface plasmon and it has been commercialised to study the binding kinetics of biomolecules. The EOT biosensor is based on enhanced light transmission when it goes through a metallic periodic array of subwavelength nanoholes. A fibre-optic SPR-EOT biosensor is fabricated by transferring a thin gold film with a nanohole matrix to a tip of an optical fibre. The portability and practicability of the EOT biosensor are significantly enhanced thanks to this fabricating technique. In this thesis, I evaluated the performance of fibre-optic SPR-EOT biosensors in detecting different biomolecules including monoclonal antibodies, toxin B and spike proteins by optimising the fabricating procedure and the sensing surface preparation process. Furthermore, regeneration of the sensing surface was also studied to allow multiple use of these sensors. The fibre-optic SPR-EOT biosensor was evaluated as a process analytical technology tool for detection and measurements of monoclonal antibodies in the bioreactor during the antibody manufacture process. Peaks at 830 nm of light transmission spectra were shifted during the detection. The biosensor detected an antibody concentration as low as 4.4×10-4 mg/mL. Due to the robustness of protein A, the protein A-based biosensor was tested for surface regeneration, and the result demonstrated that the biosensor could withstand up to 10 regenerations using 0.1 M glycine hydrochloride (pH=2.8). The biosensor was also assessed for detection of biomolecules for disease diagnosis at the early phase. It was used to detect toxin B produced from Clostridium Difficile with the limit of detection of 1.4 pg/ml, which was comparable to other novel methods. A procedure of preparing the fabricating materials and the fabrication process were established to ensure a consistent batch-to-batch quality of the biosensor. The potential of using the biosensor for early diagnosis of Clostridium Difficile infection was revealed through three batches of toxin B samples. Finally, the biosensor was tested for rapid detection of the N protein of the SARS-CoV2 virus. The limit of detection was 1.77 μg/mL, which was far above that obtained from other detection methods (ELISA and lateral flow assay for COVID-19 diagnosis) although these methods often take a much longer time than our developed biosensor. The limit of detection could be lowered to 0.046 pg/mL by altering the fabricating method and materials, but the quality of fabricated biosensors would not be consistent. This thesis accentuates the potential of fibre-optic SPR-EOT biosensors for bioapplications, especially for analytical and diagnostic applications. My PhD study has contributed to preparation of the biosensor components, establishment of fabricating techniques, and development of methods of functionalization, which lay a solid foundation for commercialisation of the fibre-optic SPR-EOT biosensor.","abstract_html":"A fibre-optic surface plasmon resonance-extraordinary optical transmission (SPR-EOT) biosensor is developed based on a conventional SPR biosensor, utilising optical fibres and extraordinary optical transmission to miniaturise the biosensor for point-of-care diagnosis and real-time online analysis. The SPR biosensor is a well-established biosensing platform based on surface plasmon and it has been commercialised to study the binding kinetics of biomolecules. The EOT biosensor is based on enhanced light transmission when it goes through a metallic periodic array of subwavelength nanoholes. A fibre-optic SPR-EOT biosensor is fabricated by transferring a thin gold film with a nanohole matrix to a tip of an optical fibre. The portability and practicability of the EOT biosensor are significantly enhanced thanks to this fabricating technique. In this thesis, I evaluated the performance of fibre-optic SPR-EOT biosensors in detecting different biomolecules including monoclonal antibodies, toxin B and spike proteins by optimising the fabricating procedure and the sensing surface preparation process. Furthermore, regeneration of the sensing surface was also studied to allow multiple use of these sensors. The fibre-optic SPR-EOT biosensor was evaluated as a process analytical technology tool for detection and measurements of monoclonal antibodies in the bioreactor during the antibody manufacture process. Peaks at 830 nm of light transmission spectra were shifted during the detection. The biosensor detected an antibody concentration as low as 4.4×10-4 mg/mL. Due to the robustness of protein A, the protein A-based biosensor was tested for surface regeneration, and the result demonstrated that the biosensor could withstand up to 10 regenerations using 0.1 M glycine hydrochloride (pH=2.8). The biosensor was also assessed for detection of biomolecules for disease diagnosis at the early phase. It was used to detect toxin B produced from Clostridium Difficile with the limit of detection of 1.4 pg/ml, which was comparable to other novel methods. A procedure of preparing the fabricating materials and the fabrication process were established to ensure a consistent batch-to-batch quality of the biosensor. The potential of using the biosensor for early diagnosis of Clostridium Difficile infection was revealed through three batches of toxin B samples. Finally, the biosensor was tested for rapid detection of the N protein of the SARS-CoV2 virus. The limit of detection was 1.77 μg/mL, which was far above that obtained from other detection methods (ELISA and lateral flow assay for COVID-19 diagnosis) although these methods often take a much longer time than our developed biosensor. The limit of detection could be lowered to 0.046 pg/mL by altering the fabricating method and materials, but the quality of fabricated biosensors would not be consistent. This thesis accentuates the potential of fibre-optic SPR-EOT biosensors for bioapplications, especially for analytical and diagnostic applications. My PhD study has contributed to preparation of the biosensor components, establishment of fabricating techniques, and development of methods of functionalization, which lay a solid foundation for commercialisation of the fibre-optic SPR-EOT biosensor.","abstract_has_math":false,"creators":["Ly, Thai Thao"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":"School of Chemical Engineering and Advanced Materials","contributors":[],"advisors":["Zhang, Hu","Ruan, Yinlan","Bi, Jingxiu"],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021","date_published":"2021","updated_at":"2026-11-19T14:04:29Z","subjects":["Optical biosensor","SPR biosensor","EOT biosensor","Surface plasmon resonance","Extraordinary optical transmission","Fibre-optic biosensor"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2440/135246","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2440/135246","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aadelaide%3Aoai%3Adigital.library.adelaide.edu.au%3A2440%2F135246","prefix":"oai_dc"},"source_record":{"url":"https://digital.library.adelaide.edu.au/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.library.adelaide.edu.au%3A2440%2F135246","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zhang, Hu","Ruan, Yinlan","Bi, Jingxiu"]},{"key":"dc:contributor.school","label":"School","values":["School of Chemical Engineering and Advanced Materials"]},{"key":"dc:creator","label":"Author","values":["Ly, Thai Thao"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2021"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Optical biosensor","SPR biosensor","EOT biosensor","Surface plasmon resonance","Extraordinary optical transmission","Fibre-optic biosensor"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2440/135246"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A fibre-optic surface plasmon resonance-extraordinary optical transmission (SPR-EOT) biosensor is developed based on a conventional SPR biosensor, utilising optical fibres and extraordinary optical transmission to miniaturise the biosensor for point-of-care diagnosis and real-time online analysis. The SPR biosensor is a well-established biosensing platform based on surface plasmon and it has been commercialised to study the binding kinetics of biomolecules. The EOT biosensor is based on enhanced light transmission when it goes through a metallic periodic array of subwavelength nanoholes. A fibre-optic SPR-EOT biosensor is fabricated by transferring a thin gold film with a nanohole matrix to a tip of an optical fibre. The portability and practicability of the EOT biosensor are significantly enhanced thanks to this fabricating technique. In this thesis, I evaluated the performance of fibre-optic SPR-EOT biosensors in detecting different biomolecules including monoclonal antibodies, toxin B and spike proteins by optimising the fabricating procedure and the sensing surface preparation process. Furthermore, regeneration of the sensing surface was also studied to allow multiple use of these sensors. The fibre-optic SPR-EOT biosensor was evaluated as a process analytical technology tool for detection and measurements of monoclonal antibodies in the bioreactor during the antibody manufacture process. Peaks at 830 nm of light transmission spectra were shifted during the detection. The biosensor detected an antibody concentration as low as 4.4×10-4 mg/mL. Due to the robustness of protein A, the protein A-based biosensor was tested for surface regeneration, and the result demonstrated that the biosensor could withstand up to 10 regenerations using 0.1 M glycine hydrochloride (pH=2.8). The biosensor was also assessed for detection of biomolecules for disease diagnosis at the early phase. It was used to detect toxin B produced from Clostridium Difficile with the limit of detection of 1.4 pg/ml, which was comparable to other novel methods. A procedure of preparing the fabricating materials and the fabrication process were established to ensure a consistent batch-to-batch quality of the biosensor. The potential of using the biosensor for early diagnosis of Clostridium Difficile infection was revealed through three batches of toxin B samples. Finally, the biosensor was tested for rapid detection of the N protein of the SARS-CoV2 virus. The limit of detection was 1.77 μg/mL, which was far above that obtained from other detection methods (ELISA and lateral flow assay for COVID-19 diagnosis) although these methods often take a much longer time than our developed biosensor. The limit of detection could be lowered to 0.046 pg/mL by altering the fabricating method and materials, but the quality of fabricated biosensors would not be consistent. This thesis accentuates the potential of fibre-optic SPR-EOT biosensors for bioapplications, especially for analytical and diagnostic applications. My PhD study has contributed to preparation of the biosensor components, establishment of fabricating techniques, and development of methods of functionalization, which lay a solid foundation for commercialisation of the fibre-optic SPR-EOT biosensor."]},{"key":"dc:description.dissertation","label":"Dc Description Dissertation","values":["Thesis (Ph.D.) -- University of Adelaide, School of Chemical Engineering and Advanced Materials, 2022"]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["This electronic version is made publicly available by the University of Adelaide in accordance with its open access policy for student theses. Copyright in this thesis remains with the author. This thesis may incorporate third party material which has been used by the author pursuant to Fair Dealing exceptions. If you are the owner of any included third party copyright material you wish to be removed from this electronic version, please complete the take down form located at: http://www.adelaide.edu.au/legals"]},{"key":"dc:title","label":"Title","values":["A Study of the Analytical and Diagnostic Potential of Fibre-Optic Surface Plasmon Resonance-Extraordinary Optical Transmission Biosensors"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zhang, Hu","Ruan, Yinlan","Bi, Jingxiu"],"dc:contributor.school":["School of Chemical Engineering and Advanced Materials"],"dc:creator":["Ly, Thai Thao"],"dc:date.issued":["2021"],"dc:description.abstract":["A fibre-optic surface plasmon resonance-extraordinary optical transmission (SPR-EOT) biosensor is developed based on a conventional SPR biosensor, utilising optical fibres and extraordinary optical transmission to miniaturise the biosensor for point-of-care diagnosis and real-time online analysis. The SPR biosensor is a well-established biosensing platform based on surface plasmon and it has been commercialised to study the binding kinetics of biomolecules. The EOT biosensor is based on enhanced light transmission when it goes through a metallic periodic array of subwavelength nanoholes. A fibre-optic SPR-EOT biosensor is fabricated by transferring a thin gold film with a nanohole matrix to a tip of an optical fibre. The portability and practicability of the EOT biosensor are significantly enhanced thanks to this fabricating technique. In this thesis, I evaluated the performance of fibre-optic SPR-EOT biosensors in detecting different biomolecules including monoclonal antibodies, toxin B and spike proteins by optimising the fabricating procedure and the sensing surface preparation process. Furthermore, regeneration of the sensing surface was also studied to allow multiple use of these sensors. The fibre-optic SPR-EOT biosensor was evaluated as a process analytical technology tool for detection and measurements of monoclonal antibodies in the bioreactor during the antibody manufacture process. Peaks at 830 nm of light transmission spectra were shifted during the detection. The biosensor detected an antibody concentration as low as 4.4×10-4 mg/mL. Due to the robustness of protein A, the protein A-based biosensor was tested for surface regeneration, and the result demonstrated that the biosensor could withstand up to 10 regenerations using 0.1 M glycine hydrochloride (pH=2.8). The biosensor was also assessed for detection of biomolecules for disease diagnosis at the early phase. It was used to detect toxin B produced from Clostridium Difficile with the limit of detection of 1.4 pg/ml, which was comparable to other novel methods. A procedure of preparing the fabricating materials and the fabrication process were established to ensure a consistent batch-to-batch quality of the biosensor. The potential of using the biosensor for early diagnosis of Clostridium Difficile infection was revealed through three batches of toxin B samples. Finally, the biosensor was tested for rapid detection of the N protein of the SARS-CoV2 virus. The limit of detection was 1.77 μg/mL, which was far above that obtained from other detection methods (ELISA and lateral flow assay for COVID-19 diagnosis) although these methods often take a much longer time than our developed biosensor. The limit of detection could be lowered to 0.046 pg/mL by altering the fabricating method and materials, but the quality of fabricated biosensors would not be consistent. This thesis accentuates the potential of fibre-optic SPR-EOT biosensors for bioapplications, especially for analytical and diagnostic applications. My PhD study has contributed to preparation of the biosensor components, establishment of fabricating techniques, and development of methods of functionalization, which lay a solid foundation for commercialisation of the fibre-optic SPR-EOT biosensor."],"dc:description.dissertation":["Thesis (Ph.D.) -- University of Adelaide, School of Chemical Engineering and Advanced Materials, 2022"],"dc:description.provenance":["This electronic version is made publicly available by the University of Adelaide in accordance with its open access policy for student theses. Copyright in this thesis remains with the author. This thesis may incorporate third party material which has been used by the author pursuant to Fair Dealing exceptions. If you are the owner of any included third party copyright material you wish to be removed from this electronic version, please complete the take down form located at: http://www.adelaide.edu.au/legals"],"dc:identifier.uri":["https://hdl.handle.net/2440/135246"],"dc:language.iso":["en"],"dc:subject":["Optical biosensor","SPR biosensor","EOT biosensor","Surface plasmon resonance","Extraordinary optical transmission","Fibre-optic biosensor"],"dc:title":["A Study of the Analytical and Diagnostic Potential of Fibre-Optic Surface Plasmon Resonance-Extraordinary Optical Transmission Biosensors"],"dc:type":["Thesis"]},"updated_at":"2026-11-19T14:04:29Z"}