{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/101040"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/101040","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Influence of Bubble Size on an Effervescent Atomization","abstract":"An experimental investigation was performed to study the influence of the bubble size on an effervescent atomization. Experiments were conducted in horizontal facility with a 25.4mm diameter feeding pipe using water and air as the working fluids that were sprayed through an effervescent nozzle. Water flow rates from 113 to 189 kg/min and air to liquid mass ratios from 1% to 4% were selected. High speed photographs, of the bubbles in the feeding conduit and of the resulting droplets on the spray, were taken to use the particle projected areas to estimate their sizes. A monotonic positive correlation was found between the bubble size and the droplet size, in a fairly narrow range of feed flow void fractions. A bubble size sensitivity parameter was defined. Knowledge of the droplet behaviour provides data to enhance the design and operating conditions of the atomization process and a means to control droplet size.","abstract_html":"An experimental investigation was performed to study the influence of the bubble size on an effervescent atomization. Experiments were conducted in horizontal facility with a 25.4mm diameter feeding pipe using water and air as the working fluids that were sprayed through an effervescent nozzle. Water flow rates from 113 to 189 kg/min and air to liquid mass ratios from 1% to 4% were selected. High speed photographs, of the bubbles in the feeding conduit and of the resulting droplets on the spray, were taken to use the particle projected areas to estimate their sizes. A monotonic positive correlation was found between the bubble size and the droplet size, in a fairly narrow range of feed flow void fractions. A bubble size sensitivity parameter was defined. Knowledge of the droplet behaviour provides data to enhance the design and operating conditions of the atomization process and a means to control droplet size.","abstract_has_math":false,"creators":["Gomez, Johana"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Olfert, Jason (Mechanical Engineering)","Fleck, Brian (Mechanical Engineering)"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-11","date_published":"2010-11","updated_at":"2026-11-26T20:58:28Z","subjects":["Bubble size","Effervescent atomization","Droplet size"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3212K","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3212K","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F101040","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F101040","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Olfert, Jason (Mechanical Engineering)","Fleck, Brian (Mechanical Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Fleck, Brian (Mechanical Engineering)","Nobes, David (Mechanical Engineering)","Olfert, Jason (Mechanical Engineering)","Sander, Sean (Chemical and Materials Engineering)"]},{"key":"dc:creator","label":"Author","values":["Gomez, Johana"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T16:09:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T16:09:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bubble size","Effervescent atomization","Droplet size"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3212K"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An experimental investigation was performed to study the influence of the bubble size on an effervescent atomization. Experiments were conducted in horizontal facility with a 25.4mm diameter feeding pipe using water and air as the working fluids that were sprayed through an effervescent nozzle. Water flow rates from 113 to 189 kg/min and air to liquid mass ratios from 1% to 4% were selected. High speed photographs, of the bubbles in the feeding conduit and of the resulting droplets on the spray, were taken to use the particle projected areas to estimate their sizes. A monotonic positive correlation was found between the bubble size and the droplet size, in a fairly narrow range of feed flow void fractions. A bubble size sensitivity parameter was defined. Knowledge of the droplet behaviour provides data to enhance the design and operating conditions of the atomization process and a means to control droplet size."]},{"key":"dc:title","label":"Title","values":["Influence of Bubble Size on an Effervescent Atomization"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Olfert, Jason (Mechanical Engineering)","Fleck, Brian (Mechanical Engineering)"],"dc:contributor.other":["Fleck, Brian (Mechanical Engineering)","Nobes, David (Mechanical Engineering)","Olfert, Jason (Mechanical Engineering)","Sander, Sean (Chemical and Materials Engineering)"],"dc:creator":["Gomez, Johana"],"dc:date.accessioned":["2025-05-29T16:09:13Z"],"dc:date.available":["2025-05-29T16:09:13Z"],"dc:date.issued":["2010-11"],"dc:description.abstract":["An experimental investigation was performed to study the influence of the bubble size on an effervescent atomization. Experiments were conducted in horizontal facility with a 25.4mm diameter feeding pipe using water and air as the working fluids that were sprayed through an effervescent nozzle. Water flow rates from 113 to 189 kg/min and air to liquid mass ratios from 1% to 4% were selected. High speed photographs, of the bubbles in the feeding conduit and of the resulting droplets on the spray, were taken to use the particle projected areas to estimate their sizes. A monotonic positive correlation was found between the bubble size and the droplet size, in a fairly narrow range of feed flow void fractions. A bubble size sensitivity parameter was defined. Knowledge of the droplet behaviour provides data to enhance the design and operating conditions of the atomization process and a means to control droplet size."],"dc:identifier.doi":["https://doi.org/10.7939/R3212K"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Bubble size","Effervescent atomization","Droplet size"],"dc:title":["Influence of Bubble Size on an Effervescent Atomization"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T20:58:28Z"}