{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/104357"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/104357","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Numerical Modeling of Welders’ Exposure to Welding Fumes","abstract":"Welding is a commonly employed industrial process that produces fumes containing hazardous substances, which may lead to adverse health effects. To mitigate these risks, it is crucial to assess the workers’ exposure to welding fumes under actual conditions to provide effective protective strategies. This thesis comprises two studies that collectively evaluate exposure to welding fumes through numerical modeling and simulation, aiming to develop practical strategies to enhance the protection of workers in welding workshop environments. Study 1 is a literature review and aims to evaluate the application of Computational Fluid Dynamics (CFD) in assessing exposure to welding fumes, comparing it with traditional experimental methods, such as air sampling and biological monitoring. While experimental approaches provide direct exposure data, they are often invasive, time-consuming, and expensive. Conversely, CFD offers a flexible and non-invasive approach by simulating airborne fume concentrations and evaluating the performance of engineering controls, such as local exhaust ventilation systems. The review examines recent advances in CFD modeling techniques, assesses their effectiveness in estimating exposure levels, and discusses their usefulness in guiding design choices. The findings show that the use of CFD in welding fume exposure assessment is still limited, highlighting a critical gap in current knowledge. However, CFD simulations can identify high-exposure zones that traditional methods may miss and demonstrate that well-designed ventilation can cut fume concentrations by up to ten times. Despite challenges with modeling complexity and parameter sensitivity, the review emphasizes CFD’s potential to improve worker safety in welding environments, while also acknowledging its current limitations. Study 2 aims to develop a CFD model to simulate the dispersion of welding fumes within a full-scale booth and to identify strategies to mitigate welder exposure. By incorporating thermal buoyancy effects and particle tracking, the model evaluated fume behavior under various conditions, including different ventilation rates, local exhaust ventilation (LEV) configurations, ceiling geometries, welding durations, and welder postures. The results indicate that increased background airflow reduces contaminant concentrations but does not entirely eliminate recirculation zones. LEV systems aligned with thermal plumes and positioned near the weld substantially enhance capture efficiency, while pyramidal ceiling designs facilitate vertical extraction. Additionally, welder posture influences exposure levels; standing improves clearance but elevates short-term risks, whereas sitting decreases peak exposure but extends particle residence time. Under optimal conditions, most particles were effectively exhausted with minimal residual deposition. These findings underscore the importance of integrating airflow management, welder posture, and booth geometry to improve welder protection.","abstract_html":"Welding is a commonly employed industrial process that produces fumes containing hazardous substances, which may lead to adverse health effects. To mitigate these risks, it is crucial to assess the workers’ exposure to welding fumes under actual conditions to provide effective protective strategies. This thesis comprises two studies that collectively evaluate exposure to welding fumes through numerical modeling and simulation, aiming to develop practical strategies to enhance the protection of workers in welding workshop environments. Study 1 is a literature review and aims to evaluate the application of Computational Fluid Dynamics (CFD) in assessing exposure to welding fumes, comparing it with traditional experimental methods, such as air sampling and biological monitoring. While experimental approaches provide direct exposure data, they are often invasive, time-consuming, and expensive. Conversely, CFD offers a flexible and non-invasive approach by simulating airborne fume concentrations and evaluating the performance of engineering controls, such as local exhaust ventilation systems. The review examines recent advances in CFD modeling techniques, assesses their effectiveness in estimating exposure levels, and discusses their usefulness in guiding design choices. The findings show that the use of CFD in welding fume exposure assessment is still limited, highlighting a critical gap in current knowledge. However, CFD simulations can identify high-exposure zones that traditional methods may miss and demonstrate that well-designed ventilation can cut fume concentrations by up to ten times. Despite challenges with modeling complexity and parameter sensitivity, the review emphasizes CFD’s potential to improve worker safety in welding environments, while also acknowledging its current limitations. Study 2 aims to develop a CFD model to simulate the dispersion of welding fumes within a full-scale booth and to identify strategies to mitigate welder exposure. By incorporating thermal buoyancy effects and particle tracking, the model evaluated fume behavior under various conditions, including different ventilation rates, local exhaust ventilation (LEV) configurations, ceiling geometries, welding durations, and welder postures. The results indicate that increased background airflow reduces contaminant concentrations but does not entirely eliminate recirculation zones. LEV systems aligned with thermal plumes and positioned near the weld substantially enhance capture efficiency, while pyramidal ceiling designs facilitate vertical extraction. Additionally, welder posture influences exposure levels; standing improves clearance but elevates short-term risks, whereas sitting decreases peak exposure but extends particle residence time. Under optimal conditions, most particles were effectively exhausted with minimal residual deposition. These findings underscore the importance of integrating airflow management, welder posture, and booth geometry to improve welder protection.","abstract_has_math":false,"creators":["Ahmadzadeh, Mahdi"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":"Environmental Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Zaher Hashisho (Civil and Environmental Engineering)","Bernadette Quemerais (Medicine)"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-11","date_published":"2025-11","updated_at":"2026-11-26T20:59:44Z","subjects":["Welding fume","exposure assessment","computational fluid dynamics","particle dispersion","indoor air quality","discrete phase model"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/83065","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/83065","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F104357","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F104357","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zaher Hashisho (Civil and Environmental Engineering)","Bernadette Quemerais (Medicine)"]},{"key":"dc:creator","label":"Author","values":["Ahmadzadeh, Mahdi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-11-17T16:21:23Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Welding fume","exposure assessment","computational fluid dynamics","particle dispersion","indoor air quality","discrete phase model"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/83065"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Welding is a commonly employed industrial process that produces fumes containing hazardous substances, which may lead to adverse health effects. To mitigate these risks, it is crucial to assess the workers’ exposure to welding fumes under actual conditions to provide effective protective strategies. This thesis comprises two studies that collectively evaluate exposure to welding fumes through numerical modeling and simulation, aiming to develop practical strategies to enhance the protection of workers in welding workshop environments. Study 1 is a literature review and aims to evaluate the application of Computational Fluid Dynamics (CFD) in assessing exposure to welding fumes, comparing it with traditional experimental methods, such as air sampling and biological monitoring. While experimental approaches provide direct exposure data, they are often invasive, time-consuming, and expensive. Conversely, CFD offers a flexible and non-invasive approach by simulating airborne fume concentrations and evaluating the performance of engineering controls, such as local exhaust ventilation systems. The review examines recent advances in CFD modeling techniques, assesses their effectiveness in estimating exposure levels, and discusses their usefulness in guiding design choices. The findings show that the use of CFD in welding fume exposure assessment is still limited, highlighting a critical gap in current knowledge. However, CFD simulations can identify high-exposure zones that traditional methods may miss and demonstrate that well-designed ventilation can cut fume concentrations by up to ten times. Despite challenges with modeling complexity and parameter sensitivity, the review emphasizes CFD’s potential to improve worker safety in welding environments, while also acknowledging its current limitations. Study 2 aims to develop a CFD model to simulate the dispersion of welding fumes within a full-scale booth and to identify strategies to mitigate welder exposure. By incorporating thermal buoyancy effects and particle tracking, the model evaluated fume behavior under various conditions, including different ventilation rates, local exhaust ventilation (LEV) configurations, ceiling geometries, welding durations, and welder postures. The results indicate that increased background airflow reduces contaminant concentrations but does not entirely eliminate recirculation zones. LEV systems aligned with thermal plumes and positioned near the weld substantially enhance capture efficiency, while pyramidal ceiling designs facilitate vertical extraction. Additionally, welder posture influences exposure levels; standing improves clearance but elevates short-term risks, whereas sitting decreases peak exposure but extends particle residence time. Under optimal conditions, most particles were effectively exhausted with minimal residual deposition. These findings underscore the importance of integrating airflow management, welder posture, and booth geometry to improve welder protection."]},{"key":"dc:title","label":"Title","values":["Numerical Modeling of Welders’ Exposure to Welding Fumes"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zaher Hashisho (Civil and Environmental Engineering)","Bernadette Quemerais (Medicine)"],"dc:creator":["Ahmadzadeh, Mahdi"],"dc:date.accessioned":["2025-11-17T16:21:23Z"],"dc:date.issued":["2025-11"],"dc:description.abstract":["Welding is a commonly employed industrial process that produces fumes containing hazardous substances, which may lead to adverse health effects. To mitigate these risks, it is crucial to assess the workers’ exposure to welding fumes under actual conditions to provide effective protective strategies. This thesis comprises two studies that collectively evaluate exposure to welding fumes through numerical modeling and simulation, aiming to develop practical strategies to enhance the protection of workers in welding workshop environments. Study 1 is a literature review and aims to evaluate the application of Computational Fluid Dynamics (CFD) in assessing exposure to welding fumes, comparing it with traditional experimental methods, such as air sampling and biological monitoring. While experimental approaches provide direct exposure data, they are often invasive, time-consuming, and expensive. Conversely, CFD offers a flexible and non-invasive approach by simulating airborne fume concentrations and evaluating the performance of engineering controls, such as local exhaust ventilation systems. The review examines recent advances in CFD modeling techniques, assesses their effectiveness in estimating exposure levels, and discusses their usefulness in guiding design choices. The findings show that the use of CFD in welding fume exposure assessment is still limited, highlighting a critical gap in current knowledge. However, CFD simulations can identify high-exposure zones that traditional methods may miss and demonstrate that well-designed ventilation can cut fume concentrations by up to ten times. Despite challenges with modeling complexity and parameter sensitivity, the review emphasizes CFD’s potential to improve worker safety in welding environments, while also acknowledging its current limitations. Study 2 aims to develop a CFD model to simulate the dispersion of welding fumes within a full-scale booth and to identify strategies to mitigate welder exposure. By incorporating thermal buoyancy effects and particle tracking, the model evaluated fume behavior under various conditions, including different ventilation rates, local exhaust ventilation (LEV) configurations, ceiling geometries, welding durations, and welder postures. The results indicate that increased background airflow reduces contaminant concentrations but does not entirely eliminate recirculation zones. LEV systems aligned with thermal plumes and positioned near the weld substantially enhance capture efficiency, while pyramidal ceiling designs facilitate vertical extraction. Additionally, welder posture influences exposure levels; standing improves clearance but elevates short-term risks, whereas sitting decreases peak exposure but extends particle residence time. Under optimal conditions, most particles were effectively exhausted with minimal residual deposition. These findings underscore the importance of integrating airflow management, welder posture, and booth geometry to improve welder protection."],"dc:identifier.doi":["https://doi.org/10.7939/83065"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Welding fume","exposure assessment","computational fluid dynamics","particle dispersion","indoor air quality","discrete phase model"],"dc:title":["Numerical Modeling of Welders’ Exposure to Welding Fumes"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Environmental Engineering"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T20:59:44Z"}