{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/104649"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/104649","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"3D-3D rigid registration of echocardiographic images obtained from apical window","abstract":"Echocardiography is widely used in clinics to assess heart function and structure. However, it suffers from a limited field of view. There are no algorithms that enable perfect alignment of 3D echocardiographic images captured from various angles to improve image quality and broaden the field of view. This study proposes an accelerated sequential Monte Carlo (SMC) algorithm for 3D-3D rigid registration of transthoracic echocardiographic images with significant and limited overlap taken from the apical window that is robust to the noise and intensity variation in ultrasound images. The SMC algorithm estimates the translational and rotational components of the rigid transform through an iterative process and requires an initial approximation of the translation and rotation limits. We perform registration in two ways: image-based registration computes the transform to align the end-diastolic frame of the apical nonstandard image to the apical standard image and applies the same transform to all frames of the cardiac cycle, whereas mask-based registration approach uses the binary masks of the left ventricle in the same way. The SMC and exhaustive search (EX) algorithms were evaluated for 4D temporal sequences recorded from 7 volunteers who participated in a study conducted at the Mazankowski Alberta Heart Institute. The evaluations demonstrate that the mask-based approach of the accelerated SMC yielded a Dice score value of 0.819 ± 0.045 for the left ventricle and gained 16.7 × speedup compared to the CPU version of the SMC algorithm. The mask-based accelerated SMC-based approach performs well compared to the other approaches in terms of accuracy and computational time.","abstract_html":"Echocardiography is widely used in clinics to assess heart function and structure. However, it suffers from a limited field of view. There are no algorithms that enable perfect alignment of 3D echocardiographic images captured from various angles to improve image quality and broaden the field of view. This study proposes an accelerated sequential Monte Carlo (SMC) algorithm for 3D-3D rigid registration of transthoracic echocardiographic images with significant and limited overlap taken from the apical window that is robust to the noise and intensity variation in ultrasound images. The SMC algorithm estimates the translational and rotational components of the rigid transform through an iterative process and requires an initial approximation of the translation and rotation limits. We perform registration in two ways: image-based registration computes the transform to align the end-diastolic frame of the apical nonstandard image to the apical standard image and applies the same transform to all frames of the cardiac cycle, whereas mask-based registration approach uses the binary masks of the left ventricle in the same way. The SMC and exhaustive search (EX) algorithms were evaluated for 4D temporal sequences recorded from 7 volunteers who participated in a study conducted at the Mazankowski Alberta Heart Institute. The evaluations demonstrate that the mask-based approach of the accelerated SMC yielded a Dice score value of 0.819 ± 0.045 for the left ventricle and gained 16.7 × speedup compared to the CPU version of the SMC algorithm. The mask-based accelerated SMC-based approach performs well compared to the other approaches in terms of accuracy and computational time.","abstract_has_math":false,"creators":["Uruththirakodeeswaran, Thanuja"],"institution":"University of Alberta","degree_name":"Doctor of Philosophy","degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Punithakumar, Kumaradevan (Radiology and Diagnostic Imaging)","Le, Lawrence (Radiology and Diagnostic Imaging)"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-11","date_published":"2025-11","updated_at":"2026-11-26T21:04:26Z","subjects":["Sequential Monte Carlo","Particle Filter","3D-3D rigid registration","Echocardiographic images"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":["https://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/83357","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/83357","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F104649","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F104649","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Punithakumar, Kumaradevan (Radiology and Diagnostic Imaging)","Le, Lawrence (Radiology and Diagnostic Imaging)"]},{"key":"dc:creator","label":"Author","values":["Uruththirakodeeswaran, Thanuja"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-11-17T16:26:21Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Sequential Monte Carlo","Particle Filter","3D-3D rigid registration","Echocardiographic images"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/83357"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Echocardiography is widely used in clinics to assess heart function and structure. However, it suffers from a limited field of view. There are no algorithms that enable perfect alignment of 3D echocardiographic images captured from various angles to improve image quality and broaden the field of view. This study proposes an accelerated sequential Monte Carlo (SMC) algorithm for 3D-3D rigid registration of transthoracic echocardiographic images with significant and limited overlap taken from the apical window that is robust to the noise and intensity variation in ultrasound images. The SMC algorithm estimates the translational and rotational components of the rigid transform through an iterative process and requires an initial approximation of the translation and rotation limits. We perform registration in two ways: image-based registration computes the transform to align the end-diastolic frame of the apical nonstandard image to the apical standard image and applies the same transform to all frames of the cardiac cycle, whereas mask-based registration approach uses the binary masks of the left ventricle in the same way. The SMC and exhaustive search (EX) algorithms were evaluated for 4D temporal sequences recorded from 7 volunteers who participated in a study conducted at the Mazankowski Alberta Heart Institute. The evaluations demonstrate that the mask-based approach of the accelerated SMC yielded a Dice score value of 0.819 ± 0.045 for the left ventricle and gained 16.7 × speedup compared to the CPU version of the SMC algorithm. The mask-based accelerated SMC-based approach performs well compared to the other approaches in terms of accuracy and computational time."]},{"key":"dc:title","label":"Title","values":["3D-3D rigid registration of echocardiographic images obtained from apical window"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Punithakumar, Kumaradevan (Radiology and Diagnostic Imaging)","Le, Lawrence (Radiology and Diagnostic Imaging)"],"dc:creator":["Uruththirakodeeswaran, Thanuja"],"dc:date.accessioned":["2025-11-17T16:26:21Z"],"dc:date.issued":["2025-11"],"dc:description.abstract":["Echocardiography is widely used in clinics to assess heart function and structure. However, it suffers from a limited field of view. There are no algorithms that enable perfect alignment of 3D echocardiographic images captured from various angles to improve image quality and broaden the field of view. This study proposes an accelerated sequential Monte Carlo (SMC) algorithm for 3D-3D rigid registration of transthoracic echocardiographic images with significant and limited overlap taken from the apical window that is robust to the noise and intensity variation in ultrasound images. The SMC algorithm estimates the translational and rotational components of the rigid transform through an iterative process and requires an initial approximation of the translation and rotation limits. We perform registration in two ways: image-based registration computes the transform to align the end-diastolic frame of the apical nonstandard image to the apical standard image and applies the same transform to all frames of the cardiac cycle, whereas mask-based registration approach uses the binary masks of the left ventricle in the same way. The SMC and exhaustive search (EX) algorithms were evaluated for 4D temporal sequences recorded from 7 volunteers who participated in a study conducted at the Mazankowski Alberta Heart Institute. The evaluations demonstrate that the mask-based approach of the accelerated SMC yielded a Dice score value of 0.819 ± 0.045 for the left ventricle and gained 16.7 × speedup compared to the CPU version of the SMC algorithm. The mask-based accelerated SMC-based approach performs well compared to the other approaches in terms of accuracy and computational time."],"dc:identifier.doi":["https://doi.org/10.7939/83357"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:rights.uri":["https://creativecommons.org/licenses/by/4.0/"],"dc:subject":["Sequential Monte Carlo","Particle Filter","3D-3D rigid registration","Echocardiographic images"],"dc:title":["3D-3D rigid registration of echocardiographic images obtained from apical window"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:04:26Z"}