{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/104656"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/104656","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Characterizing the Repeatability and Reproducibility of Cardiovascular Responses to Hypoxic Apneas","abstract":"Background: We and others have demonstrated that voluntary apneas performed during acute and chronic hypoxia cause pronounced bradycardia and a higher incidence of cardiac arrhythmias compared to apneas under normoxic conditions. What remains unclear is the consistency of these responses. Therefore, we assessed the intra-individual repeatability (within-day: “day 1”) and reproducibility (between-day: “both days”) of cardiovascular responses to hypoxic apneas, including the genesis of arrhythmias. Methods: Sixteen participants (eight females, 25 ± 3 years, BMI 23.7 ± 3.4 kg/m2, mean ± standard deviation) completed four hypoxic apneas per day on consecutive days, all time-matched to the longest of two maximal apneas on day 1 (39 ± 16 s duration). We quantified heart rate (HR) and mean arterial pressure (MAP) repeatability and reproducibility using within-subject standard deviations (WSSD), [95% confidence interval (CI)]. We also assessed arrhythmia reproducibility using overall incidence (% of all apneas with an arrhythmia) and affected individuals’ incidence, the median and interquartile range of intra-individual arrhythmia occurrences, including only individuals who had at least one arrhythmia. Results: Apneas caused pronounced bradycardia (day 1 = -17 ± 10 bpm; both days = -16 ± 11 bpm) and displayed excellent to good HR repeatability (day 1 WSSD = 5.0 bpm, 95% CI [4.2, 6.4]) and good reproducibility (both days WSSD = 5.9 bpm, 95% CI [5.2, 6.9]). MAP consistently increased during apneas (day 1 = +21 ± 10 mmHg; both days = +21 ± 10 mmHg) and displayed excellent to good repeatability (day 1 WSSD = 3.9 mmHg, 95% CI [3.2, 4.9]) and good reproducibility (both days WSSD = 4.7 mmHg, 95% CI [4.2, 5.5]). Arrhythmias occurred inconsistently with 53.9% overall incidence and 68.8% (37.5%, 87.5%) affected individuals’ incidence among 14 participants with ≥1 arrhythmia. No arrhythmia type occurred consistently; junctional escapes had the highest overall incidence at 28.9% in 11 participants, and premature ventricular contractions had the lowest overall incidence at 5.5% in three participants. Conclusions: Together, these data indicate that HR and MAP responses to hypoxic apneas are consistent at the intra-individual level, but that arrhythmogenic responses to hypoxic apneas cannot be predicted from a preceding apnea. This work helps define physiological responsiveness and prognostic utility under these conditions.","abstract_html":"Background: We and others have demonstrated that voluntary apneas performed during acute and chronic hypoxia cause pronounced bradycardia and a higher incidence of cardiac arrhythmias compared to apneas under normoxic conditions. What remains unclear is the consistency of these responses. Therefore, we assessed the intra-individual repeatability (within-day: “day 1”) and reproducibility (between-day: “both days”) of cardiovascular responses to hypoxic apneas, including the genesis of arrhythmias. Methods: Sixteen participants (eight females, 25 ± 3 years, BMI 23.7 ± 3.4 kg/m2, mean ± standard deviation) completed four hypoxic apneas per day on consecutive days, all time-matched to the longest of two maximal apneas on day 1 (39 ± 16 s duration). We quantified heart rate (HR) and mean arterial pressure (MAP) repeatability and reproducibility using within-subject standard deviations (WSSD), [95% confidence interval (CI)]. We also assessed arrhythmia reproducibility using overall incidence (% of all apneas with an arrhythmia) and affected individuals’ incidence, the median and interquartile range of intra-individual arrhythmia occurrences, including only individuals who had at least one arrhythmia. Results: Apneas caused pronounced bradycardia (day 1 = -17 ± 10 bpm; both days = -16 ± 11 bpm) and displayed excellent to good HR repeatability (day 1 WSSD = 5.0 bpm, 95% CI [4.2, 6.4]) and good reproducibility (both days WSSD = 5.9 bpm, 95% CI [5.2, 6.9]). MAP consistently increased during apneas (day 1 = +21 ± 10 mmHg; both days = +21 ± 10 mmHg) and displayed excellent to good repeatability (day 1 WSSD = 3.9 mmHg, 95% CI [3.2, 4.9]) and good reproducibility (both days WSSD = 4.7 mmHg, 95% CI [4.2, 5.5]). Arrhythmias occurred inconsistently with 53.9% overall incidence and 68.8% (37.5%, 87.5%) affected individuals’ incidence among 14 participants with ≥1 arrhythmia. No arrhythmia type occurred consistently; junctional escapes had the highest overall incidence at 28.9% in 11 participants, and premature ventricular contractions had the lowest overall incidence at 5.5% in three participants. Conclusions: Together, these data indicate that HR and MAP responses to hypoxic apneas are consistent at the intra-individual level, but that arrhythmogenic responses to hypoxic apneas cannot be predicted from a preceding apnea. This work helps define physiological responsiveness and prognostic utility under these conditions.","abstract_has_math":false,"creators":["Young, Desmond A"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Steinback, Craig (Kinesiology, Sport, and Recreation)"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-11","date_published":"2025-11","updated_at":"2026-11-26T20:55:14Z","subjects":["Apnea","Repeatability","Heart rate","Breath hold","Reliability","Cardiovascular","Arrhythmia","Reproducibility","Hypoxia"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":["https://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/83364","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/83364","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F104656","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F104656","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Steinback, Craig (Kinesiology, Sport, and Recreation)"]},{"key":"dc:creator","label":"Author","values":["Young, Desmond A"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-11-17T16:26:48Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Apnea","Repeatability","Heart rate","Breath hold","Reliability","Cardiovascular","Arrhythmia","Reproducibility","Hypoxia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/83364"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Background: We and others have demonstrated that voluntary apneas performed during acute and chronic hypoxia cause pronounced bradycardia and a higher incidence of cardiac arrhythmias compared to apneas under normoxic conditions. What remains unclear is the consistency of these responses. Therefore, we assessed the intra-individual repeatability (within-day: “day 1”) and reproducibility (between-day: “both days”) of cardiovascular responses to hypoxic apneas, including the genesis of arrhythmias. Methods: Sixteen participants (eight females, 25 ± 3 years, BMI 23.7 ± 3.4 kg/m2, mean ± standard deviation) completed four hypoxic apneas per day on consecutive days, all time-matched to the longest of two maximal apneas on day 1 (39 ± 16 s duration). We quantified heart rate (HR) and mean arterial pressure (MAP) repeatability and reproducibility using within-subject standard deviations (WSSD), [95% confidence interval (CI)]. We also assessed arrhythmia reproducibility using overall incidence (% of all apneas with an arrhythmia) and affected individuals’ incidence, the median and interquartile range of intra-individual arrhythmia occurrences, including only individuals who had at least one arrhythmia. Results: Apneas caused pronounced bradycardia (day 1 = -17 ± 10 bpm; both days = -16 ± 11 bpm) and displayed excellent to good HR repeatability (day 1 WSSD = 5.0 bpm, 95% CI [4.2, 6.4]) and good reproducibility (both days WSSD = 5.9 bpm, 95% CI [5.2, 6.9]). MAP consistently increased during apneas (day 1 = +21 ± 10 mmHg; both days = +21 ± 10 mmHg) and displayed excellent to good repeatability (day 1 WSSD = 3.9 mmHg, 95% CI [3.2, 4.9]) and good reproducibility (both days WSSD = 4.7 mmHg, 95% CI [4.2, 5.5]). Arrhythmias occurred inconsistently with 53.9% overall incidence and 68.8% (37.5%, 87.5%) affected individuals’ incidence among 14 participants with ≥1 arrhythmia. No arrhythmia type occurred consistently; junctional escapes had the highest overall incidence at 28.9% in 11 participants, and premature ventricular contractions had the lowest overall incidence at 5.5% in three participants. Conclusions: Together, these data indicate that HR and MAP responses to hypoxic apneas are consistent at the intra-individual level, but that arrhythmogenic responses to hypoxic apneas cannot be predicted from a preceding apnea. This work helps define physiological responsiveness and prognostic utility under these conditions."]},{"key":"dc:title","label":"Title","values":["Characterizing the Repeatability and Reproducibility of Cardiovascular Responses to Hypoxic Apneas"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Steinback, Craig (Kinesiology, Sport, and Recreation)"],"dc:creator":["Young, Desmond A"],"dc:date.accessioned":["2025-11-17T16:26:48Z"],"dc:date.issued":["2025-11"],"dc:description.abstract":["Background: We and others have demonstrated that voluntary apneas performed during acute and chronic hypoxia cause pronounced bradycardia and a higher incidence of cardiac arrhythmias compared to apneas under normoxic conditions. What remains unclear is the consistency of these responses. Therefore, we assessed the intra-individual repeatability (within-day: “day 1”) and reproducibility (between-day: “both days”) of cardiovascular responses to hypoxic apneas, including the genesis of arrhythmias. Methods: Sixteen participants (eight females, 25 ± 3 years, BMI 23.7 ± 3.4 kg/m2, mean ± standard deviation) completed four hypoxic apneas per day on consecutive days, all time-matched to the longest of two maximal apneas on day 1 (39 ± 16 s duration). We quantified heart rate (HR) and mean arterial pressure (MAP) repeatability and reproducibility using within-subject standard deviations (WSSD), [95% confidence interval (CI)]. We also assessed arrhythmia reproducibility using overall incidence (% of all apneas with an arrhythmia) and affected individuals’ incidence, the median and interquartile range of intra-individual arrhythmia occurrences, including only individuals who had at least one arrhythmia. Results: Apneas caused pronounced bradycardia (day 1 = -17 ± 10 bpm; both days = -16 ± 11 bpm) and displayed excellent to good HR repeatability (day 1 WSSD = 5.0 bpm, 95% CI [4.2, 6.4]) and good reproducibility (both days WSSD = 5.9 bpm, 95% CI [5.2, 6.9]). MAP consistently increased during apneas (day 1 = +21 ± 10 mmHg; both days = +21 ± 10 mmHg) and displayed excellent to good repeatability (day 1 WSSD = 3.9 mmHg, 95% CI [3.2, 4.9]) and good reproducibility (both days WSSD = 4.7 mmHg, 95% CI [4.2, 5.5]). Arrhythmias occurred inconsistently with 53.9% overall incidence and 68.8% (37.5%, 87.5%) affected individuals’ incidence among 14 participants with ≥1 arrhythmia. No arrhythmia type occurred consistently; junctional escapes had the highest overall incidence at 28.9% in 11 participants, and premature ventricular contractions had the lowest overall incidence at 5.5% in three participants. Conclusions: Together, these data indicate that HR and MAP responses to hypoxic apneas are consistent at the intra-individual level, but that arrhythmogenic responses to hypoxic apneas cannot be predicted from a preceding apnea. This work helps define physiological responsiveness and prognostic utility under these conditions."],"dc:identifier.doi":["https://doi.org/10.7939/83364"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:rights.uri":["https://creativecommons.org/licenses/by/4.0/"],"dc:subject":["Apnea","Repeatability","Heart rate","Breath hold","Reliability","Cardiovascular","Arrhythmia","Reproducibility","Hypoxia"],"dc:title":["Characterizing the Repeatability and Reproducibility of Cardiovascular Responses to Hypoxic Apneas"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T20:55:14Z"}