{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/107147"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/107147","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Interdigitated Electrode-based Microfluidic Biosensing Platforms For Biomedical Applications","abstract":"This thesis presents a systematic investigation into the development, optimization, and application of interdigitated electrode (IDE)-based microfluidic biosensing platforms for point-of-care diagnostics and single-cell analysis. The research addresses critical limitations in current biosensing technologies, particularly regarding sensitivity, portability, and multifunctionality in complex biological environments.The initial phase of investigation was focused on the development of a portable electrochemical impedance spectroscopy (EIS) platform for rapid detection of anti-SARS-CoV-2 antibodies in serum samples. A non-Faradaic EIS approach utilizing gold nanoparticles (GNPs) conjugated with protein G showed significant distinguish between positive and negative Covid serum samples, with maximum statistical significance (p = 7×10^-6) observed at 10 kHz. The platform achieved relative impedance changes of 27.2% ± 13.6% and 4.1% ± 1.7% for positive and negative samples, respectively, establishing a diagnostic threshold of 10% impedance change.Subsequently, comprehensive parametric optimization of electrode geometry was conducted to enhance biosensor sensitivity. A three-dimensional (3D) computational model using COMSOL Multiphysics revealed a linear correlation between sensitivity and inter-electrode gap parameters. Experimental validation with fabricated IDE chips (featuring inter-electrode gaps of 3 μm, 4 μm, and 5 μm) confirmed that the 3 μm configuration exhibited superior detection capability, successfully identifying monoclonal antibody concentrations as low as 50 ng/mL — a threshold unattainable with alternative configurations.Building upon these findings, the research expanded IDE functionality through integration with negative dielectrophoresis (nDEP) and microwell structures for single-cell manipulation and analysis. A novel approach involving direct glass etching to create microwell structures was developed, eliminating the need for additional material layers that reduce nDEP capture efficiency. Systematic finite element analysis optimized microfluidic channel dimensions for effective cellular manipulation. The platform demonstrated successful single-cell trapping of both synthetic microparticles and HEK-293 cells with high specificity. Impedance measurements established a linear relationship between the number of captured particles and corresponding impedance changes (R² values of 0.9565 and 0.9242 for microbeads and cells, respectively), enabling quantitative assessment without optical monitoring. Furthermore, the platform was able to reach single cell lysis through freeze-thaw protocol with oil-sealing methodology. Phenotypic observation at single cell resolution was then validated through fluorescence microscopy. To the authors' knowledge, this represents the first successful integration of nDEP with microwell structures for single-cell capture and analysis in physiological media characterized by high conductivity — overcoming a significant limitation of conventional dielectrophoretic approaches.The multifunctional analytical platform developed in this research offers significant advantages for biomedical applications, including miniaturization, automation, high sensitivity, and portability. The integration of IDE structures with microfluidic channels and microwell arrays provides versatile capabilities for biomolecular detection, cellular manipulation, and single-cell analysis. This work contributes to advancing point-of-care diagnostic technologies and establishes methodological frameworks for future investigations in biomedical engineering and analytical sciences.The research presented here demonstrates the potential of integrated biosensing platforms to address contemporary challenges in healthcare diagnostics and fundamental biological research through innovative engineering approaches and cross-disciplinary integration.","abstract_html":"This thesis presents a systematic investigation into the development, optimization, and application of interdigitated electrode (IDE)-based microfluidic biosensing platforms for point-of-care diagnostics and single-cell analysis. The research addresses critical limitations in current biosensing technologies, particularly regarding sensitivity, portability, and multifunctionality in complex biological environments.The initial phase of investigation was focused on the development of a portable electrochemical impedance spectroscopy (EIS) platform for rapid detection of anti-SARS-CoV-2 antibodies in serum samples. A non-Faradaic EIS approach utilizing gold nanoparticles (GNPs) conjugated with protein G showed significant distinguish between positive and negative Covid serum samples, with maximum statistical significance (p = 7×10^-6) observed at 10 kHz. The platform achieved relative impedance changes of 27.2% ± 13.6% and 4.1% ± 1.7% for positive and negative samples, respectively, establishing a diagnostic threshold of 10% impedance change.Subsequently, comprehensive parametric optimization of electrode geometry was conducted to enhance biosensor sensitivity. A three-dimensional (3D) computational model using COMSOL Multiphysics revealed a linear correlation between sensitivity and inter-electrode gap parameters. Experimental validation with fabricated IDE chips (featuring inter-electrode gaps of 3 μm, 4 μm, and 5 μm) confirmed that the 3 μm configuration exhibited superior detection capability, successfully identifying monoclonal antibody concentrations as low as 50 ng/mL — a threshold unattainable with alternative configurations.Building upon these findings, the research expanded IDE functionality through integration with negative dielectrophoresis (nDEP) and microwell structures for single-cell manipulation and analysis. A novel approach involving direct glass etching to create microwell structures was developed, eliminating the need for additional material layers that reduce nDEP capture efficiency. Systematic finite element analysis optimized microfluidic channel dimensions for effective cellular manipulation. The platform demonstrated successful single-cell trapping of both synthetic microparticles and HEK-293 cells with high specificity. Impedance measurements established a linear relationship between the number of captured particles and corresponding impedance changes (R² values of 0.9565 and 0.9242 for microbeads and cells, respectively), enabling quantitative assessment without optical monitoring. Furthermore, the platform was able to reach single cell lysis through freeze-thaw protocol with oil-sealing methodology. Phenotypic observation at single cell resolution was then validated through fluorescence microscopy. To the authors&#x27; knowledge, this represents the first successful integration of nDEP with microwell structures for single-cell capture and analysis in physiological media characterized by high conductivity — overcoming a significant limitation of conventional dielectrophoretic approaches.The multifunctional analytical platform developed in this research offers significant advantages for biomedical applications, including miniaturization, automation, high sensitivity, and portability. The integration of IDE structures with microfluidic channels and microwell arrays provides versatile capabilities for biomolecular detection, cellular manipulation, and single-cell analysis. This work contributes to advancing point-of-care diagnostic technologies and establishes methodological frameworks for future investigations in biomedical engineering and analytical sciences.The research presented here demonstrates the potential of integrated biosensing platforms to address contemporary challenges in healthcare diagnostics and fundamental biological research through innovative engineering approaches and cross-disciplinary integration.","abstract_has_math":false,"creators":["Jiang, Tianxiang"],"institution":"University of Alberta","degree_name":"Doctor of Philosophy","degree_level":"Doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Jie Chen (Electrical and Computer Engineering)","Xihua Wang (Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-11","date_published":"2025-11","updated_at":"2026-11-26T21:00:43Z","subjects":["Biosensors","Dielectrophoresis","Microfluidic"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/85653","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/85653","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F107147","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F107147","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jie Chen (Electrical and Computer Engineering)","Xihua Wang (Electrical and Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Jiang, Tianxiang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-11-16T14:01:31Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biosensors","Dielectrophoresis","Microfluidic"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/85653"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents a systematic investigation into the development, optimization, and application of interdigitated electrode (IDE)-based microfluidic biosensing platforms for point-of-care diagnostics and single-cell analysis. The research addresses critical limitations in current biosensing technologies, particularly regarding sensitivity, portability, and multifunctionality in complex biological environments.The initial phase of investigation was focused on the development of a portable electrochemical impedance spectroscopy (EIS) platform for rapid detection of anti-SARS-CoV-2 antibodies in serum samples. A non-Faradaic EIS approach utilizing gold nanoparticles (GNPs) conjugated with protein G showed significant distinguish between positive and negative Covid serum samples, with maximum statistical significance (p = 7×10^-6) observed at 10 kHz. The platform achieved relative impedance changes of 27.2% ± 13.6% and 4.1% ± 1.7% for positive and negative samples, respectively, establishing a diagnostic threshold of 10% impedance change.Subsequently, comprehensive parametric optimization of electrode geometry was conducted to enhance biosensor sensitivity. A three-dimensional (3D) computational model using COMSOL Multiphysics revealed a linear correlation between sensitivity and inter-electrode gap parameters. Experimental validation with fabricated IDE chips (featuring inter-electrode gaps of 3 μm, 4 μm, and 5 μm) confirmed that the 3 μm configuration exhibited superior detection capability, successfully identifying monoclonal antibody concentrations as low as 50 ng/mL — a threshold unattainable with alternative configurations.Building upon these findings, the research expanded IDE functionality through integration with negative dielectrophoresis (nDEP) and microwell structures for single-cell manipulation and analysis. A novel approach involving direct glass etching to create microwell structures was developed, eliminating the need for additional material layers that reduce nDEP capture efficiency. Systematic finite element analysis optimized microfluidic channel dimensions for effective cellular manipulation. The platform demonstrated successful single-cell trapping of both synthetic microparticles and HEK-293 cells with high specificity. Impedance measurements established a linear relationship between the number of captured particles and corresponding impedance changes (R² values of 0.9565 and 0.9242 for microbeads and cells, respectively), enabling quantitative assessment without optical monitoring. Furthermore, the platform was able to reach single cell lysis through freeze-thaw protocol with oil-sealing methodology. Phenotypic observation at single cell resolution was then validated through fluorescence microscopy. To the authors' knowledge, this represents the first successful integration of nDEP with microwell structures for single-cell capture and analysis in physiological media characterized by high conductivity — overcoming a significant limitation of conventional dielectrophoretic approaches.The multifunctional analytical platform developed in this research offers significant advantages for biomedical applications, including miniaturization, automation, high sensitivity, and portability. The integration of IDE structures with microfluidic channels and microwell arrays provides versatile capabilities for biomolecular detection, cellular manipulation, and single-cell analysis. This work contributes to advancing point-of-care diagnostic technologies and establishes methodological frameworks for future investigations in biomedical engineering and analytical sciences.The research presented here demonstrates the potential of integrated biosensing platforms to address contemporary challenges in healthcare diagnostics and fundamental biological research through innovative engineering approaches and cross-disciplinary integration."]},{"key":"dc:title","label":"Title","values":["Interdigitated Electrode-based Microfluidic Biosensing Platforms For Biomedical Applications"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jie Chen (Electrical and Computer Engineering)","Xihua Wang (Electrical and Computer Engineering)"],"dc:creator":["Jiang, Tianxiang"],"dc:date.accessioned":["2026-11-16T14:01:31Z"],"dc:date.issued":["2025-11"],"dc:description.abstract":["This thesis presents a systematic investigation into the development, optimization, and application of interdigitated electrode (IDE)-based microfluidic biosensing platforms for point-of-care diagnostics and single-cell analysis. The research addresses critical limitations in current biosensing technologies, particularly regarding sensitivity, portability, and multifunctionality in complex biological environments.The initial phase of investigation was focused on the development of a portable electrochemical impedance spectroscopy (EIS) platform for rapid detection of anti-SARS-CoV-2 antibodies in serum samples. A non-Faradaic EIS approach utilizing gold nanoparticles (GNPs) conjugated with protein G showed significant distinguish between positive and negative Covid serum samples, with maximum statistical significance (p = 7×10^-6) observed at 10 kHz. The platform achieved relative impedance changes of 27.2% ± 13.6% and 4.1% ± 1.7% for positive and negative samples, respectively, establishing a diagnostic threshold of 10% impedance change.Subsequently, comprehensive parametric optimization of electrode geometry was conducted to enhance biosensor sensitivity. A three-dimensional (3D) computational model using COMSOL Multiphysics revealed a linear correlation between sensitivity and inter-electrode gap parameters. Experimental validation with fabricated IDE chips (featuring inter-electrode gaps of 3 μm, 4 μm, and 5 μm) confirmed that the 3 μm configuration exhibited superior detection capability, successfully identifying monoclonal antibody concentrations as low as 50 ng/mL — a threshold unattainable with alternative configurations.Building upon these findings, the research expanded IDE functionality through integration with negative dielectrophoresis (nDEP) and microwell structures for single-cell manipulation and analysis. A novel approach involving direct glass etching to create microwell structures was developed, eliminating the need for additional material layers that reduce nDEP capture efficiency. Systematic finite element analysis optimized microfluidic channel dimensions for effective cellular manipulation. The platform demonstrated successful single-cell trapping of both synthetic microparticles and HEK-293 cells with high specificity. Impedance measurements established a linear relationship between the number of captured particles and corresponding impedance changes (R² values of 0.9565 and 0.9242 for microbeads and cells, respectively), enabling quantitative assessment without optical monitoring. Furthermore, the platform was able to reach single cell lysis through freeze-thaw protocol with oil-sealing methodology. Phenotypic observation at single cell resolution was then validated through fluorescence microscopy. To the authors' knowledge, this represents the first successful integration of nDEP with microwell structures for single-cell capture and analysis in physiological media characterized by high conductivity — overcoming a significant limitation of conventional dielectrophoretic approaches.The multifunctional analytical platform developed in this research offers significant advantages for biomedical applications, including miniaturization, automation, high sensitivity, and portability. The integration of IDE structures with microfluidic channels and microwell arrays provides versatile capabilities for biomolecular detection, cellular manipulation, and single-cell analysis. This work contributes to advancing point-of-care diagnostic technologies and establishes methodological frameworks for future investigations in biomedical engineering and analytical sciences.The research presented here demonstrates the potential of integrated biosensing platforms to address contemporary challenges in healthcare diagnostics and fundamental biological research through innovative engineering approaches and cross-disciplinary integration."],"dc:identifier.doi":["https://doi.org/10.7939/85653"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Biosensors","Dielectrophoresis","Microfluidic"],"dc:title":["Interdigitated Electrode-based Microfluidic Biosensing Platforms For Biomedical Applications"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:00:43Z"}