{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/58438"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/58438","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Spatial analysis of thermal aging of overhead power transmission lines","abstract":"To meet increasing power needs of industrialized and urbanized consumers, power transmission companies are pressed to elevate the transmitted load in overhead power transmission lines. Increased loads impose thermal and mechanical stress, causing risks of transmission reliability. These risks can be mitigated by developing computational diagnostic tools for better scheduling of line inspections and maintenance. The thesis introduces a novel methodology for spatial analysis of conductor thermal aging based on historical weather data that can be performed at three different levels: point, line, and area. By utilizing this paradigm, the thermal state of an energized transmission line can be visualized, initiating a new dimension in thermal aging research. An advanced model for dynamic re-rating of existing transmission lines is introduced in the thesis to reduce the risk of sag. The performance of the thermal aging and re-rating models is examined using simulation data from the BC Hydro power transmission network.","abstract_html":"To meet increasing power needs of industrialized and urbanized consumers, power transmission companies are pressed to elevate the transmitted load in overhead power transmission lines. Increased loads impose thermal and mechanical stress, causing risks of transmission reliability. These risks can be mitigated by developing computational diagnostic tools for better scheduling of line inspections and maintenance. The thesis introduces a novel methodology for spatial analysis of conductor thermal aging based on historical weather data that can be performed at three different levels: point, line, and area. By utilizing this paradigm, the thermal state of an energized transmission line can be visualized, initiating a new dimension in thermal aging research. An advanced model for dynamic re-rating of existing transmission lines is introduced in the thesis to reduce the risk of sag. The performance of the thermal aging and re-rating models is examined using simulation data from the BC Hydro power transmission network.","abstract_has_math":false,"creators":["Bhuiyan, Md. Mafijul Islam"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Petr Musilek (Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-11","date_published":"2011-11","updated_at":"2026-11-26T21:06:05Z","subjects":["Overhead electric lines--Fault location","Powerline ampacity","Spatial analysis (Statistics)"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3S081","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3S081","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F58438","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F58438","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Petr Musilek (Electrical and Computer Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Andrew Knight (Electrical and Computer Engineering)","Aminah Robinson Fayek (Civil and Environmental Engineering)"]},{"key":"dc:creator","label":"Author","values":["Bhuiyan, Md. Mafijul Islam"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-06T15:38:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-06T15:38:05Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Overhead electric lines--Fault location","Powerline ampacity","Spatial analysis (Statistics)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3S081"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["To meet increasing power needs of industrialized and urbanized consumers, power transmission companies are pressed to elevate the transmitted load in overhead power transmission lines. Increased loads impose thermal and mechanical stress, causing risks of transmission reliability. These risks can be mitigated by developing computational diagnostic tools for better scheduling of line inspections and maintenance. The thesis introduces a novel methodology for spatial analysis of conductor thermal aging based on historical weather data that can be performed at three different levels: point, line, and area. By utilizing this paradigm, the thermal state of an energized transmission line can be visualized, initiating a new dimension in thermal aging research. An advanced model for dynamic re-rating of existing transmission lines is introduced in the thesis to reduce the risk of sag. The performance of the thermal aging and re-rating models is examined using simulation data from the BC Hydro power transmission network."]},{"key":"dc:title","label":"Title","values":["Spatial analysis of thermal aging of overhead power transmission lines"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Petr Musilek (Electrical and Computer Engineering)"],"dc:contributor.other":["Andrew Knight (Electrical and Computer Engineering)","Aminah Robinson Fayek (Civil and Environmental Engineering)"],"dc:creator":["Bhuiyan, Md. Mafijul Islam"],"dc:date.accessioned":["2025-05-06T15:38:05Z"],"dc:date.available":["2025-05-06T15:38:05Z"],"dc:date.issued":["2011-11"],"dc:description.abstract":["To meet increasing power needs of industrialized and urbanized consumers, power transmission companies are pressed to elevate the transmitted load in overhead power transmission lines. Increased loads impose thermal and mechanical stress, causing risks of transmission reliability. These risks can be mitigated by developing computational diagnostic tools for better scheduling of line inspections and maintenance. The thesis introduces a novel methodology for spatial analysis of conductor thermal aging based on historical weather data that can be performed at three different levels: point, line, and area. By utilizing this paradigm, the thermal state of an energized transmission line can be visualized, initiating a new dimension in thermal aging research. An advanced model for dynamic re-rating of existing transmission lines is introduced in the thesis to reduce the risk of sag. The performance of the thermal aging and re-rating models is examined using simulation data from the BC Hydro power transmission network."],"dc:identifier.doi":["https://doi.org/10.7939/R3S081"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Overhead electric lines--Fault location","Powerline ampacity","Spatial analysis (Statistics)"],"dc:title":["Spatial analysis of thermal aging of overhead power transmission lines"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:06:05Z"}