{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/58577"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/58577","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Heat Transfer Analysis of Microwelding Using Tuned Electron Beam","abstract":"Assembling small scale components is a challenge faced especially by the micro-electronics and medical industry that are dealing with miniaturized components. The current laser and electron beam technologies cannot be used for welding below few hundreds of micrometers because the high heat intensity resulting from reduced beam diameters causes excessive surface ablation. The current research investigates volumetric heating using tuned electron beams as a key to successfully employ high intensity heat sources for welding at micron and possibly nano scales. A numerical model has been developed using state-of-art commercial finite element software to predict the temperature distribution near the moving volumetric heat source for given welding conditions. It is observed that process Peclet number of 100 and beam penetration twice that of the required weld depth are the optimal conditions for carrying out microwelding with least supply of heat input to the substrate and negligible surface ablation.","abstract_html":"Assembling small scale components is a challenge faced especially by the micro-electronics and medical industry that are dealing with miniaturized components. The current laser and electron beam technologies cannot be used for welding below few hundreds of micrometers because the high heat intensity resulting from reduced beam diameters causes excessive surface ablation. The current research investigates volumetric heating using tuned electron beams as a key to successfully employ high intensity heat sources for welding at micron and possibly nano scales. A numerical model has been developed using state-of-art commercial finite element software to predict the temperature distribution near the moving volumetric heat source for given welding conditions. It is observed that process Peclet number of 100 and beam penetration twice that of the required weld depth are the optimal conditions for carrying out microwelding with least supply of heat input to the substrate and negligible surface ablation.","abstract_has_math":false,"creators":["Gajapathi, Satya Sai"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Sushanta K. Mitra (Mechanical Engineering)","Patricio F. Mendez (Chemical and Materials Engineering)"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-11","date_published":"2011-11","updated_at":"2026-11-26T21:09:02Z","subjects":["High power lasers--Thermal properties","Lasers in medicine","Laser welding--Thermal properties","Laser pulses, Ultrashort"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3N12V","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3N12V","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F58577","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F58577","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sushanta K. Mitra (Mechanical Engineering)","Patricio F. Mendez (Chemical and Materials Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Marc Secanell Gallart (Mechanical Engineering)"]},{"key":"dc:creator","label":"Author","values":["Gajapathi, Satya Sai"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-06T15:39:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-06T15:39:20Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["High power lasers--Thermal properties","Lasers in medicine","Laser welding--Thermal properties","Laser pulses, Ultrashort"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3N12V"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Assembling small scale components is a challenge faced especially by the micro-electronics and medical industry that are dealing with miniaturized components. The current laser and electron beam technologies cannot be used for welding below few hundreds of micrometers because the high heat intensity resulting from reduced beam diameters causes excessive surface ablation. The current research investigates volumetric heating using tuned electron beams as a key to successfully employ high intensity heat sources for welding at micron and possibly nano scales. A numerical model has been developed using state-of-art commercial finite element software to predict the temperature distribution near the moving volumetric heat source for given welding conditions. It is observed that process Peclet number of 100 and beam penetration twice that of the required weld depth are the optimal conditions for carrying out microwelding with least supply of heat input to the substrate and negligible surface ablation."]},{"key":"dc:title","label":"Title","values":["Heat Transfer Analysis of Microwelding Using Tuned Electron Beam"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sushanta K. Mitra (Mechanical Engineering)","Patricio F. Mendez (Chemical and Materials Engineering)"],"dc:contributor.other":["Marc Secanell Gallart (Mechanical Engineering)"],"dc:creator":["Gajapathi, Satya Sai"],"dc:date.accessioned":["2025-05-06T15:39:20Z"],"dc:date.available":["2025-05-06T15:39:20Z"],"dc:date.issued":["2011-11"],"dc:description.abstract":["Assembling small scale components is a challenge faced especially by the micro-electronics and medical industry that are dealing with miniaturized components. The current laser and electron beam technologies cannot be used for welding below few hundreds of micrometers because the high heat intensity resulting from reduced beam diameters causes excessive surface ablation. The current research investigates volumetric heating using tuned electron beams as a key to successfully employ high intensity heat sources for welding at micron and possibly nano scales. A numerical model has been developed using state-of-art commercial finite element software to predict the temperature distribution near the moving volumetric heat source for given welding conditions. It is observed that process Peclet number of 100 and beam penetration twice that of the required weld depth are the optimal conditions for carrying out microwelding with least supply of heat input to the substrate and negligible surface ablation."],"dc:identifier.doi":["https://doi.org/10.7939/R3N12V"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["High power lasers--Thermal properties","Lasers in medicine","Laser welding--Thermal properties","Laser pulses, Ultrashort"],"dc:title":["Heat Transfer Analysis of Microwelding Using Tuned Electron Beam"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:09:02Z"}