{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/59477"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/59477","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Specific phage based bacteria detection using microcantilever sensors","abstract":"Resonant microcantilevers are promising transducers for bacteria detection because of their high sensitivities. Surface stress and mass from adsorbates affect the resonant frequency. We developed a novel method for decoupling the frequency contributions of a change in mass and surface stress on a cantilever sensor validated in theoretical, finite element and experimental framework. Bacteria capture was achieved by several different chemical immobilization of T4 phages. The most successful bacteria capturing surface produced bacterial densities of about 11 bacteria/100^m2. The developed theory is then applied to determine captured bacterial mass on the cantilevers. This provides an estimate of the bacteria mass on the cantilever. Two different functionalizations resulted in predicted bacterial densities of 5 bacteria/100^m2 and 3 bacteria/100^m2. Poor densities relative to surface capture experiments is caused by the boundary effects of the cantilever in solution.","abstract_html":"Resonant microcantilevers are promising transducers for bacteria detection because of their high sensitivities. Surface stress and mass from adsorbates affect the resonant frequency. We developed a novel method for decoupling the frequency contributions of a change in mass and surface stress on a cantilever sensor validated in theoretical, finite element and experimental framework. Bacteria capture was achieved by several different chemical immobilization of T4 phages. The most successful bacteria capturing surface produced bacterial densities of about 11 bacteria/100^m2. The developed theory is then applied to determine captured bacterial mass on the cantilevers. This provides an estimate of the bacteria mass on the cantilever. Two different functionalizations resulted in predicted bacterial densities of 5 bacteria/100^m2 and 3 bacteria/100^m2. Poor densities relative to surface capture experiments is caused by the boundary effects of the cantilever in solution.","abstract_has_math":false,"creators":["Glass, Nicholas"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Evoy, Stephane (Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-11","date_published":"2009-11","updated_at":"2026-11-26T21:02:58Z","subjects":["Microcantilever","Biosensors","Bacteriophage","MEMS","Mass Sensor"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3NP6X","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3NP6X","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F59477","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F59477","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Evoy, Stephane (Electrical and Computer Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Brett, Michael (Electrical and Computer Engineering)","Szymanski, Christine (Biological Sciences)"]},{"key":"dc:creator","label":"Author","values":["Glass, Nicholas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-06T15:56:33Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-06T15:56:33Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microcantilever","Biosensors","Bacteriophage","MEMS","Mass Sensor"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3NP6X"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Resonant microcantilevers are promising transducers for bacteria detection because of their high sensitivities. Surface stress and mass from adsorbates affect the resonant frequency. We developed a novel method for decoupling the frequency contributions of a change in mass and surface stress on a cantilever sensor validated in theoretical, finite element and experimental framework. Bacteria capture was achieved by several different chemical immobilization of T4 phages. The most successful bacteria capturing surface produced bacterial densities of about 11 bacteria/100^m2. The developed theory is then applied to determine captured bacterial mass on the cantilevers. This provides an estimate of the bacteria mass on the cantilever. Two different functionalizations resulted in predicted bacterial densities of 5 bacteria/100^m2 and 3 bacteria/100^m2. Poor densities relative to surface capture experiments is caused by the boundary effects of the cantilever in solution."]},{"key":"dc:title","label":"Title","values":["Specific phage based bacteria detection using microcantilever sensors"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Evoy, Stephane (Electrical and Computer Engineering)"],"dc:contributor.other":["Brett, Michael (Electrical and Computer Engineering)","Szymanski, Christine (Biological Sciences)"],"dc:creator":["Glass, Nicholas"],"dc:date.accessioned":["2025-05-06T15:56:33Z"],"dc:date.available":["2025-05-06T15:56:33Z"],"dc:date.issued":["2009-11"],"dc:description.abstract":["Resonant microcantilevers are promising transducers for bacteria detection because of their high sensitivities. Surface stress and mass from adsorbates affect the resonant frequency. We developed a novel method for decoupling the frequency contributions of a change in mass and surface stress on a cantilever sensor validated in theoretical, finite element and experimental framework. Bacteria capture was achieved by several different chemical immobilization of T4 phages. The most successful bacteria capturing surface produced bacterial densities of about 11 bacteria/100^m2. The developed theory is then applied to determine captured bacterial mass on the cantilevers. This provides an estimate of the bacteria mass on the cantilever. Two different functionalizations resulted in predicted bacterial densities of 5 bacteria/100^m2 and 3 bacteria/100^m2. Poor densities relative to surface capture experiments is caused by the boundary effects of the cantilever in solution."],"dc:identifier.doi":["https://doi.org/10.7939/R3NP6X"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Microcantilever","Biosensors","Bacteriophage","MEMS","Mass Sensor"],"dc:title":["Specific phage based bacteria detection using microcantilever sensors"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:02:58Z"}