{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/60031"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/60031","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Efficient data acquisition, transmission and post-processing for quality spiral Magnetic Resonance Imaging","abstract":"Spiral Magnetic Resonance Imaging (MRI) has traditionally presented more technical and computational challenges compared to its traditional Cartesian counterpart, notably a susceptibility to blurring artifacts, especially when scan parameters are non-optimal, and a heavier computational load both at the image reconstruction, and post-processing level. This research is aimed at improving the efficiency of data acquisition, transmission and post-processing for spiral MRI, which continues to become a more common sequence choice in applications where speed, signal-to-noise ratio and geometrical accuracy are key requirements. In the first part of this thesis, we cover the fundamentals of spiral trajectory design and acquisition, image reconstruction by means of fast Gaussian gridding, and a rapid method for deblurring a large in vivo dataset. In the second part, we introduce a novel technique for compressing spiral MR data acquired from a multi-channel coil array, with applications in wireless transmission and data storage. The compressed images are indistinguishable from the originals even though the data has been compressed by a factor of 3 or more.","abstract_html":"Spiral Magnetic Resonance Imaging (MRI) has traditionally presented more technical and computational challenges compared to its traditional Cartesian counterpart, notably a susceptibility to blurring artifacts, especially when scan parameters are non-optimal, and a heavier computational load both at the image reconstruction, and post-processing level. This research is aimed at improving the efficiency of data acquisition, transmission and post-processing for spiral MRI, which continues to become a more common sequence choice in applications where speed, signal-to-noise ratio and geometrical accuracy are key requirements. In the first part of this thesis, we cover the fundamentals of spiral trajectory design and acquisition, image reconstruction by means of fast Gaussian gridding, and a rapid method for deblurring a large in vivo dataset. In the second part, we introduce a novel technique for compressing spiral MR data acquired from a multi-channel coil array, with applications in wireless transmission and data storage. The compressed images are indistinguishable from the originals even though the data has been compressed by a factor of 3 or more.","abstract_has_math":false,"creators":["Jutras, Jean-David"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Thompson, Richard (Biomedical Engineering)","Fallone, B. Gino (Oncology)","Wachowicz, Keith (Oncology)","De Zanche, Nicola (Oncology)"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-11","date_published":"2011-11","updated_at":"2026-11-26T21:14:50Z","subjects":["Spectral compression","High-density coil arrays","Dynamic range","Artifact correction","Wireless coils","Spiral MRI","Image deblurring","Data compression"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R38070","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R38070","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F60031","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F60031","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Thompson, Richard (Biomedical Engineering)","Fallone, B. Gino (Oncology)","Wachowicz, Keith (Oncology)","De Zanche, Nicola (Oncology)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Thompson, Richard (Biomedical Engineering)","De Zanche, Nicola (Oncology)","Fallone, B. Gino (Oncology)","Wilman, Alan (Biomedical Engineering)","Wachowicz, Keith (Oncology)"]},{"key":"dc:creator","label":"Author","values":["Jutras, Jean-David"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-06T16:14:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-06T16:14:36Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Spectral compression","High-density coil arrays","Dynamic range","Artifact correction","Wireless coils","Spiral MRI","Image deblurring","Data compression"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R38070"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Spiral Magnetic Resonance Imaging (MRI) has traditionally presented more technical and computational challenges compared to its traditional Cartesian counterpart, notably a susceptibility to blurring artifacts, especially when scan parameters are non-optimal, and a heavier computational load both at the image reconstruction, and post-processing level. This research is aimed at improving the efficiency of data acquisition, transmission and post-processing for spiral MRI, which continues to become a more common sequence choice in applications where speed, signal-to-noise ratio and geometrical accuracy are key requirements. In the first part of this thesis, we cover the fundamentals of spiral trajectory design and acquisition, image reconstruction by means of fast Gaussian gridding, and a rapid method for deblurring a large in vivo dataset. In the second part, we introduce a novel technique for compressing spiral MR data acquired from a multi-channel coil array, with applications in wireless transmission and data storage. The compressed images are indistinguishable from the originals even though the data has been compressed by a factor of 3 or more."]},{"key":"dc:title","label":"Title","values":["Efficient data acquisition, transmission and post-processing for quality spiral Magnetic Resonance Imaging"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Thompson, Richard (Biomedical Engineering)","Fallone, B. Gino (Oncology)","Wachowicz, Keith (Oncology)","De Zanche, Nicola (Oncology)"],"dc:contributor.other":["Thompson, Richard (Biomedical Engineering)","De Zanche, Nicola (Oncology)","Fallone, B. Gino (Oncology)","Wilman, Alan (Biomedical Engineering)","Wachowicz, Keith (Oncology)"],"dc:creator":["Jutras, Jean-David"],"dc:date.accessioned":["2025-05-06T16:14:36Z"],"dc:date.available":["2025-05-06T16:14:36Z"],"dc:date.issued":["2011-11"],"dc:description.abstract":["Spiral Magnetic Resonance Imaging (MRI) has traditionally presented more technical and computational challenges compared to its traditional Cartesian counterpart, notably a susceptibility to blurring artifacts, especially when scan parameters are non-optimal, and a heavier computational load both at the image reconstruction, and post-processing level. This research is aimed at improving the efficiency of data acquisition, transmission and post-processing for spiral MRI, which continues to become a more common sequence choice in applications where speed, signal-to-noise ratio and geometrical accuracy are key requirements. In the first part of this thesis, we cover the fundamentals of spiral trajectory design and acquisition, image reconstruction by means of fast Gaussian gridding, and a rapid method for deblurring a large in vivo dataset. In the second part, we introduce a novel technique for compressing spiral MR data acquired from a multi-channel coil array, with applications in wireless transmission and data storage. The compressed images are indistinguishable from the originals even though the data has been compressed by a factor of 3 or more."],"dc:identifier.doi":["https://doi.org/10.7939/R38070"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Spectral compression","High-density coil arrays","Dynamic range","Artifact correction","Wireless coils","Spiral MRI","Image deblurring","Data compression"],"dc:title":["Efficient data acquisition, transmission and post-processing for quality spiral Magnetic Resonance Imaging"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:14:50Z"}