{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/73810"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/73810","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Recalibration of the Unit Strength Method for Determining the Compressive Strength of Grouted Concrete Masonry","abstract":"Using research that is now several decades old, the current Canadian masonry design standard, CSA S304.1-04, prescribes values for masonry design compressive strength based on the compressive strength of the concrete masonry unit and the type of mortar used in construction. The quality of unit production, masonry construction methods, and the theoretical understanding of masonry behaviour have improved significantly since these values were developed. As a consequence, current CSA S304.1-04 correlations between unit and masonry compressive strength values no longer reflect modern masonry construction and have been shown to be too conservative. In this investigation, 140 concrete masonry prisms were constructed for compression testing to recalibrate the tabulated unit strength values. An update to CSA S304.1-04 is proposed which includes strength increases of 33-40% for prisms with type N mortar, 10-30% strength increases for prisms with type S mortar and low unit strength, and 0-12% decreases with high unit strength.","abstract_html":"Using research that is now several decades old, the current Canadian masonry design standard, CSA S304.1-04, prescribes values for masonry design compressive strength based on the compressive strength of the concrete masonry unit and the type of mortar used in construction. The quality of unit production, masonry construction methods, and the theoretical understanding of masonry behaviour have improved significantly since these values were developed. As a consequence, current CSA S304.1-04 correlations between unit and masonry compressive strength values no longer reflect modern masonry construction and have been shown to be too conservative. In this investigation, 140 concrete masonry prisms were constructed for compression testing to recalibrate the tabulated unit strength values. An update to CSA S304.1-04 is proposed which includes strength increases of 33-40% for prisms with type N mortar, 10-30% strength increases for prisms with type S mortar and low unit strength, and 0-12% decreases with high unit strength.","abstract_has_math":false,"creators":["Ross, Michael D"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":"Structural Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Korany, Yasser (Civil and Environmental Engineering)"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-06","date_published":"2013-06","updated_at":"2026-11-26T20:53:40Z","subjects":["Grouted masonry","Unit strength method","Masonry"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3Z992","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3Z992","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F73810","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F73810","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Korany, Yasser (Civil and Environmental Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Gul, Mustafa (Civil and Environmental Engineering)","Jar, Ben (Mechanical Engineering)"]},{"key":"dc:creator","label":"Author","values":["Ross, Michael D"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-28T18:59:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-28T18:59:22Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Structural Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Grouted masonry","Unit strength method","Masonry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3Z992"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Using research that is now several decades old, the current Canadian masonry design standard, CSA S304.1-04, prescribes values for masonry design compressive strength based on the compressive strength of the concrete masonry unit and the type of mortar used in construction. The quality of unit production, masonry construction methods, and the theoretical understanding of masonry behaviour have improved significantly since these values were developed. As a consequence, current CSA S304.1-04 correlations between unit and masonry compressive strength values no longer reflect modern masonry construction and have been shown to be too conservative. In this investigation, 140 concrete masonry prisms were constructed for compression testing to recalibrate the tabulated unit strength values. An update to CSA S304.1-04 is proposed which includes strength increases of 33-40% for prisms with type N mortar, 10-30% strength increases for prisms with type S mortar and low unit strength, and 0-12% decreases with high unit strength."]},{"key":"dc:title","label":"Title","values":["Recalibration of the Unit Strength Method for Determining the Compressive Strength of Grouted Concrete Masonry"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Korany, Yasser (Civil and Environmental Engineering)"],"dc:contributor.other":["Gul, Mustafa (Civil and Environmental Engineering)","Jar, Ben (Mechanical Engineering)"],"dc:creator":["Ross, Michael D"],"dc:date.accessioned":["2025-05-28T18:59:22Z"],"dc:date.available":["2025-05-28T18:59:22Z"],"dc:date.issued":["2013-06"],"dc:description.abstract":["Using research that is now several decades old, the current Canadian masonry design standard, CSA S304.1-04, prescribes values for masonry design compressive strength based on the compressive strength of the concrete masonry unit and the type of mortar used in construction. The quality of unit production, masonry construction methods, and the theoretical understanding of masonry behaviour have improved significantly since these values were developed. As a consequence, current CSA S304.1-04 correlations between unit and masonry compressive strength values no longer reflect modern masonry construction and have been shown to be too conservative. In this investigation, 140 concrete masonry prisms were constructed for compression testing to recalibrate the tabulated unit strength values. An update to CSA S304.1-04 is proposed which includes strength increases of 33-40% for prisms with type N mortar, 10-30% strength increases for prisms with type S mortar and low unit strength, and 0-12% decreases with high unit strength."],"dc:identifier.doi":["https://doi.org/10.7939/R3Z992"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Grouted masonry","Unit strength method","Masonry"],"dc:title":["Recalibration of the Unit Strength Method for Determining the Compressive Strength of Grouted Concrete Masonry"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Structural Engineering"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T20:53:40Z"}