{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/74916"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/74916","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Development of a sulfate microelectrode for profiling environmental biofilms","abstract":"Microelectrodes can be used for profiling environmental biofilms. Currently there is no sulfate microelectrode available for studying sulfate reduction in biofilms. In this study, a sulfate microelectrode was fabricated and tested in measurement of environmental biofilms for the first time. The composition of the sulfate-sensing membrane in the microelectrode was optimized. The sulfate microelectrode, with a tip diameter of 20 micrometres, displayed satisfying selectivity to SO42-. It exhibited log-linear response to sulfate concentration change with a Nernstian slope of -25.8 mV per concentration decade. The linear detection range was 10-5 M to 10-2 M SO42- with a detection limit of 10-5 M SO42- in water. The response time was 90 seconds. The sulfate microelectrode was applied on environmental biofilm samples. The sulfate profile obtained indicated the sulfate concentration change inside the biofilm. In conclusion, a sulfate microelectrode with satisfying characteristics was fabricated successfully and was useful for characterizing environmental biofilms.","abstract_html":"Microelectrodes can be used for profiling environmental biofilms. Currently there is no sulfate microelectrode available for studying sulfate reduction in biofilms. In this study, a sulfate microelectrode was fabricated and tested in measurement of environmental biofilms for the first time. The composition of the sulfate-sensing membrane in the microelectrode was optimized. The sulfate microelectrode, with a tip diameter of 20 micrometres, displayed satisfying selectivity to SO42-. It exhibited log-linear response to sulfate concentration change with a Nernstian slope of -25.8 mV per concentration decade. The linear detection range was 10-5 M to 10-2 M SO42- with a detection limit of 10-5 M SO42- in water. The response time was 90 seconds. The sulfate microelectrode was applied on environmental biofilm samples. The sulfate profile obtained indicated the sulfate concentration change inside the biofilm. In conclusion, a sulfate microelectrode with satisfying characteristics was fabricated successfully and was useful for characterizing environmental biofilms.","abstract_has_math":false,"creators":["Ren, Shujie"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Yu, Tong (Civil & Environmental Engineering)"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-11","date_published":"2011-11","updated_at":"2026-11-26T21:59:47Z","subjects":["Microelectrode","Sulfate","Biofilms","Microsensors"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3X94V","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3X94V","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F74916","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F74916","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Yu, Tong (Civil & Environmental Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Zeng, Hongbo (Chemical & Materials Engineering)","Buchanan, Ian (Civil & Environmental Engineering)"]},{"key":"dc:creator","label":"Author","values":["Ren, Shujie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-28T20:25:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-28T20:25:19Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microelectrode","Sulfate","Biofilms","Microsensors"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3X94V"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Microelectrodes can be used for profiling environmental biofilms. Currently there is no sulfate microelectrode available for studying sulfate reduction in biofilms. In this study, a sulfate microelectrode was fabricated and tested in measurement of environmental biofilms for the first time. The composition of the sulfate-sensing membrane in the microelectrode was optimized. The sulfate microelectrode, with a tip diameter of 20 micrometres, displayed satisfying selectivity to SO42-. It exhibited log-linear response to sulfate concentration change with a Nernstian slope of -25.8 mV per concentration decade. The linear detection range was 10-5 M to 10-2 M SO42- with a detection limit of 10-5 M SO42- in water. The response time was 90 seconds. The sulfate microelectrode was applied on environmental biofilm samples. The sulfate profile obtained indicated the sulfate concentration change inside the biofilm. In conclusion, a sulfate microelectrode with satisfying characteristics was fabricated successfully and was useful for characterizing environmental biofilms."]},{"key":"dc:title","label":"Title","values":["Development of a sulfate microelectrode for profiling environmental biofilms"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Yu, Tong (Civil & Environmental Engineering)"],"dc:contributor.other":["Zeng, Hongbo (Chemical & Materials Engineering)","Buchanan, Ian (Civil & Environmental Engineering)"],"dc:creator":["Ren, Shujie"],"dc:date.accessioned":["2025-05-28T20:25:19Z"],"dc:date.available":["2025-05-28T20:25:19Z"],"dc:date.issued":["2011-11"],"dc:description.abstract":["Microelectrodes can be used for profiling environmental biofilms. Currently there is no sulfate microelectrode available for studying sulfate reduction in biofilms. In this study, a sulfate microelectrode was fabricated and tested in measurement of environmental biofilms for the first time. The composition of the sulfate-sensing membrane in the microelectrode was optimized. The sulfate microelectrode, with a tip diameter of 20 micrometres, displayed satisfying selectivity to SO42-. It exhibited log-linear response to sulfate concentration change with a Nernstian slope of -25.8 mV per concentration decade. The linear detection range was 10-5 M to 10-2 M SO42- with a detection limit of 10-5 M SO42- in water. The response time was 90 seconds. The sulfate microelectrode was applied on environmental biofilm samples. The sulfate profile obtained indicated the sulfate concentration change inside the biofilm. In conclusion, a sulfate microelectrode with satisfying characteristics was fabricated successfully and was useful for characterizing environmental biofilms."],"dc:identifier.doi":["https://doi.org/10.7939/R3X94V"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Microelectrode","Sulfate","Biofilms","Microsensors"],"dc:title":["Development of a sulfate microelectrode for profiling environmental biofilms"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:59:47Z"}