{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/75745"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/75745","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Epidermal Loop Antennas","abstract":"The Quadruple Loop (QL) antenna was designed and investigated to deliver a robust body-worn antenna for bio-medical applications. The QL antenna is a very thin single-layer groundless structure which allows for the installation of neighboring electronics and sensors on biomedical device. The initial research objective was achieved after measurement results confirmed the superior performance of the QL antenna to the standard square loop. This was evident in gain and bandwidth improvement after the inclusion of the four circular patches to the original loop. In the second research stage, different fabrication tools and materials were used to make a number of QL antennas. The different antennas were intended to operate as GSM-900, GSM-1800, and BLE epidermal antennas. Radiation pattern measurements were conducted to compare their results with their simulation counterparts. Later, data communication tests showed that the acquired BER readings could qualify the BLE and GSM-900 antennas to work as part of 4-QAM wireless links. Moreover, a stretchable QL epidermal antenna made of novel silver ink had its measured results agree with simulations. Besides these hands-on endeavors, numerical analysis was used to explain the low values of gain of epidermal antennas. This is added to finding an equivalent and more efficient mathematical model of biological tissues which make up the human arm. The equivalent model was tested in software and has the practical potential to be realized in physical phantom making.","abstract_html":"The Quadruple Loop (QL) antenna was designed and investigated to deliver a robust body-worn antenna for bio-medical applications. The QL antenna is a very thin single-layer groundless structure which allows for the installation of neighboring electronics and sensors on biomedical device. The initial research objective was achieved after measurement results confirmed the superior performance of the QL antenna to the standard square loop. This was evident in gain and bandwidth improvement after the inclusion of the four circular patches to the original loop. In the second research stage, different fabrication tools and materials were used to make a number of QL antennas. The different antennas were intended to operate as GSM-900, GSM-1800, and BLE epidermal antennas. Radiation pattern measurements were conducted to compare their results with their simulation counterparts. Later, data communication tests showed that the acquired BER readings could qualify the BLE and GSM-900 antennas to work as part of 4-QAM wireless links. Moreover, a stretchable QL epidermal antenna made of novel silver ink had its measured results agree with simulations. Besides these hands-on endeavors, numerical analysis was used to explain the low values of gain of epidermal antennas. This is added to finding an equivalent and more efficient mathematical model of biological tissues which make up the human arm. The equivalent model was tested in software and has the practical potential to be realized in physical phantom making.","abstract_has_math":false,"creators":["Abu Damis, Haitham"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":"Communications","degree_department":null,"school":null,"contributors":[],"advisors":["Pedram Mousavi (Mechanical Engineering)"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-11","date_published":"2017-11","updated_at":"2026-11-26T21:04:02Z","subjects":["Body-worn antennas","Epidermal technology","Body-worn technology","Loop antennas","Electromagnetics","Antennas","Wearable technology","WBAN","Communications"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R30K26R57","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R30K26R57","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F75745","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F75745","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Pedram Mousavi (Mechanical Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Tavakoli, Mahdi (Electrical Engineering)","Chung, Hyun-Joong (Chemical and Materials Engineering)","Mousavi, Pedram (Mechanical Engineering)"]},{"key":"dc:creator","label":"Author","values":["Abu Damis, Haitham"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-28T20:36:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-28T20:36:17Z"]},{"key":"dc:date.issued","label":"Date","values":["2017-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Communications"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Body-worn antennas","Epidermal technology","Body-worn technology","Loop antennas","Electromagnetics","Antennas","Wearable technology","WBAN","Communications"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R30K26R57"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Quadruple Loop (QL) antenna was designed and investigated to deliver a robust body-worn antenna for bio-medical applications. The QL antenna is a very thin single-layer groundless structure which allows for the installation of neighboring electronics and sensors on biomedical device. The initial research objective was achieved after measurement results confirmed the superior performance of the QL antenna to the standard square loop. This was evident in gain and bandwidth improvement after the inclusion of the four circular patches to the original loop. In the second research stage, different fabrication tools and materials were used to make a number of QL antennas. The different antennas were intended to operate as GSM-900, GSM-1800, and BLE epidermal antennas. Radiation pattern measurements were conducted to compare their results with their simulation counterparts. Later, data communication tests showed that the acquired BER readings could qualify the BLE and GSM-900 antennas to work as part of 4-QAM wireless links. Moreover, a stretchable QL epidermal antenna made of novel silver ink had its measured results agree with simulations. Besides these hands-on endeavors, numerical analysis was used to explain the low values of gain of epidermal antennas. This is added to finding an equivalent and more efficient mathematical model of biological tissues which make up the human arm. The equivalent model was tested in software and has the practical potential to be realized in physical phantom making."]},{"key":"dc:title","label":"Title","values":["Epidermal Loop Antennas"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Pedram Mousavi (Mechanical Engineering)"],"dc:contributor.other":["Tavakoli, Mahdi (Electrical Engineering)","Chung, Hyun-Joong (Chemical and Materials Engineering)","Mousavi, Pedram (Mechanical Engineering)"],"dc:creator":["Abu Damis, Haitham"],"dc:date.accessioned":["2025-05-28T20:36:17Z"],"dc:date.available":["2025-05-28T20:36:17Z"],"dc:date.issued":["2017-11"],"dc:description.abstract":["The Quadruple Loop (QL) antenna was designed and investigated to deliver a robust body-worn antenna for bio-medical applications. The QL antenna is a very thin single-layer groundless structure which allows for the installation of neighboring electronics and sensors on biomedical device. The initial research objective was achieved after measurement results confirmed the superior performance of the QL antenna to the standard square loop. This was evident in gain and bandwidth improvement after the inclusion of the four circular patches to the original loop. In the second research stage, different fabrication tools and materials were used to make a number of QL antennas. The different antennas were intended to operate as GSM-900, GSM-1800, and BLE epidermal antennas. Radiation pattern measurements were conducted to compare their results with their simulation counterparts. Later, data communication tests showed that the acquired BER readings could qualify the BLE and GSM-900 antennas to work as part of 4-QAM wireless links. Moreover, a stretchable QL epidermal antenna made of novel silver ink had its measured results agree with simulations. Besides these hands-on endeavors, numerical analysis was used to explain the low values of gain of epidermal antennas. This is added to finding an equivalent and more efficient mathematical model of biological tissues which make up the human arm. The equivalent model was tested in software and has the practical potential to be realized in physical phantom making."],"dc:identifier.doi":["https://doi.org/10.7939/R30K26R57"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Body-worn antennas","Epidermal technology","Body-worn technology","Loop antennas","Electromagnetics","Antennas","Wearable technology","WBAN","Communications"],"dc:title":["Epidermal Loop Antennas"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Communications"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:04:02Z"}