{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/77958"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/77958","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Development of Surrogate Spinal Cords for the Evaluation of Electrode Arrays Used in Intraspinal Implants","abstract":"A surrogate spinal cord was developed to test the mechanical stability of electrode arrays for intraspinal implants. The mechanical and surface properties of candidate materials were tested. The elastic modulus was characterized using dynamic mechanical analysis. Forces required to indent the surrogate cords to specified depths was measured. Frictional forces were measured by pulling a needle out at a controlled rate. The results were compared to actual spinal cords, either to value from literature or ex vivo measurements. Surrogate cords with the most suitable properties (formaldehyde crosslinked gelatin, 12 wt% in water) were implanted with two types of intraspinal electrode arrays (one made of individual microwires and another of microwires anchored with a solid base), and an elongation was applied. Arrays with solid bases impeded the deformation of the cord suggesting that they could cause tissue damage in vivo, while arrays without a base moved freely with the cord.","abstract_html":"A surrogate spinal cord was developed to test the mechanical stability of electrode arrays for intraspinal implants. The mechanical and surface properties of candidate materials were tested. The elastic modulus was characterized using dynamic mechanical analysis. Forces required to indent the surrogate cords to specified depths was measured. Frictional forces were measured by pulling a needle out at a controlled rate. The results were compared to actual spinal cords, either to value from literature or ex vivo measurements. Surrogate cords with the most suitable properties (formaldehyde crosslinked gelatin, 12 wt% in water) were implanted with two types of intraspinal electrode arrays (one made of individual microwires and another of microwires anchored with a solid base), and an elongation was applied. Arrays with solid bases impeded the deformation of the cord suggesting that they could cause tissue damage in vivo, while arrays without a base moved freely with the cord.","abstract_has_math":false,"creators":["Cheng,Cheng"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":"Materials Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Elias, Anastasia (Chemical and Materials Engineering)"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-06","date_published":"2012-06","updated_at":"2026-11-26T21:06:05Z","subjects":["Mechanical testing","Gelatin","Surrogate spinal cord","Spinal cord injury","Intraspinal Microstimulations","Silicone Elastomer"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3M60H","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3M60H","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F77958","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F77958","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Elias, Anastasia (Chemical and Materials Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Elias, Anastasia (Chemical and Materials Engineering)","Nychka, John (Chemical and Materials Engineering)","Moussa, Walied (Mechanical Engineering)"]},{"key":"dc:creator","label":"Author","values":["Cheng,Cheng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-28T21:59:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-28T21:59:07Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical testing","Gelatin","Surrogate spinal cord","Spinal cord injury","Intraspinal Microstimulations","Silicone Elastomer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3M60H"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A surrogate spinal cord was developed to test the mechanical stability of electrode arrays for intraspinal implants. The mechanical and surface properties of candidate materials were tested. The elastic modulus was characterized using dynamic mechanical analysis. Forces required to indent the surrogate cords to specified depths was measured. Frictional forces were measured by pulling a needle out at a controlled rate. The results were compared to actual spinal cords, either to value from literature or ex vivo measurements. Surrogate cords with the most suitable properties (formaldehyde crosslinked gelatin, 12 wt% in water) were implanted with two types of intraspinal electrode arrays (one made of individual microwires and another of microwires anchored with a solid base), and an elongation was applied. Arrays with solid bases impeded the deformation of the cord suggesting that they could cause tissue damage in vivo, while arrays without a base moved freely with the cord."]},{"key":"dc:title","label":"Title","values":["Development of Surrogate Spinal Cords for the Evaluation of Electrode Arrays Used in Intraspinal Implants"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Elias, Anastasia (Chemical and Materials Engineering)"],"dc:contributor.other":["Elias, Anastasia (Chemical and Materials Engineering)","Nychka, John (Chemical and Materials Engineering)","Moussa, Walied (Mechanical Engineering)"],"dc:creator":["Cheng,Cheng"],"dc:date.accessioned":["2025-05-28T21:59:07Z"],"dc:date.available":["2025-05-28T21:59:07Z"],"dc:date.issued":["2012-06"],"dc:description.abstract":["A surrogate spinal cord was developed to test the mechanical stability of electrode arrays for intraspinal implants. The mechanical and surface properties of candidate materials were tested. The elastic modulus was characterized using dynamic mechanical analysis. Forces required to indent the surrogate cords to specified depths was measured. Frictional forces were measured by pulling a needle out at a controlled rate. The results were compared to actual spinal cords, either to value from literature or ex vivo measurements. Surrogate cords with the most suitable properties (formaldehyde crosslinked gelatin, 12 wt% in water) were implanted with two types of intraspinal electrode arrays (one made of individual microwires and another of microwires anchored with a solid base), and an elongation was applied. Arrays with solid bases impeded the deformation of the cord suggesting that they could cause tissue damage in vivo, while arrays without a base moved freely with the cord."],"dc:identifier.doi":["https://doi.org/10.7939/R3M60H"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Mechanical testing","Gelatin","Surrogate spinal cord","Spinal cord injury","Intraspinal Microstimulations","Silicone Elastomer"],"dc:title":["Development of Surrogate Spinal Cords for the Evaluation of Electrode Arrays Used in Intraspinal Implants"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Materials Engineering"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:06:05Z"}