{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/78048"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/78048","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Utility of Digital Surgical Simulation Planning and Solid Free Form Modeling in Fibula Free Flap Mandibular Reconstruction","abstract":"The purpose of the present study was to contribute to the growing body of knowledge and technical understanding of surgical design and simulation in fibula free flap mandibular reconstruction (FFFMR). The current study provided three key findings. (1) There was no statistically significant difference amongst the three CBCT machine warming times. There was, however, a statistically significant difference between Computerized Tomography (CT) scanning with 1mm slice thickness and CBCT scanning with 0.2mm slice thickness. (2) The convergent interview was an effective technique in collecting information about the perception of clinicians on the utility of virtual surgical planning and medical models in FFFMR. (3) Superimposed images produced in CAD software tools were helpful and effective in comparing pre and post-surgical outcomes, although there were a number of limitations in the programs. The exploratory benchtop study revealed that virtual surgical planning appeared to improve surgical performance and enhance consistency in accuracy.","abstract_html":"The purpose of the present study was to contribute to the growing body of knowledge and technical understanding of surgical design and simulation in fibula free flap mandibular reconstruction (FFFMR). The current study provided three key findings. (1) There was no statistically significant difference amongst the three CBCT machine warming times. There was, however, a statistically significant difference between Computerized Tomography (CT) scanning with 1mm slice thickness and CBCT scanning with 0.2mm slice thickness. (2) The convergent interview was an effective technique in collecting information about the perception of clinicians on the utility of virtual surgical planning and medical models in FFFMR. (3) Superimposed images produced in CAD software tools were helpful and effective in comparing pre and post-surgical outcomes, although there were a number of limitations in the programs. The exploratory benchtop study revealed that virtual surgical planning appeared to improve surgical performance and enhance consistency in accuracy.","abstract_has_math":false,"creators":["Logan, Heather Anne"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Wolfaardt, Johan (Medicine and Dentistry)"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-06","date_published":"2012-06","updated_at":"2026-11-26T21:53:41Z","subjects":["Mandibular Reconstruction","Surgical Design and Simulation","Rapid Prototyping","CT","CBCT","Medical Models","Fibula Free Flap","Convergent Interview","Digital Surgical Simulation"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R35M62F9W","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R35M62F9W","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F78048","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F78048","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wolfaardt, Johan (Medicine and Dentistry)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Jana Rieger (Speech Pathology and Audiology)","Hadi Seikaly (Medicine and Dentistry)","Bill Hodgetts (Speech Pathology and Audiology)","Pierre Boulanger (Computer Science)"]},{"key":"dc:creator","label":"Author","values":["Logan, Heather Anne"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-28T22:01:16Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-28T22:01:16Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mandibular Reconstruction","Surgical Design and Simulation","Rapid Prototyping","CT","CBCT","Medical Models","Fibula Free Flap","Convergent Interview","Digital Surgical Simulation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R35M62F9W"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of the present study was to contribute to the growing body of knowledge and technical understanding of surgical design and simulation in fibula free flap mandibular reconstruction (FFFMR). The current study provided three key findings. (1) There was no statistically significant difference amongst the three CBCT machine warming times. There was, however, a statistically significant difference between Computerized Tomography (CT) scanning with 1mm slice thickness and CBCT scanning with 0.2mm slice thickness. (2) The convergent interview was an effective technique in collecting information about the perception of clinicians on the utility of virtual surgical planning and medical models in FFFMR. (3) Superimposed images produced in CAD software tools were helpful and effective in comparing pre and post-surgical outcomes, although there were a number of limitations in the programs. The exploratory benchtop study revealed that virtual surgical planning appeared to improve surgical performance and enhance consistency in accuracy."]},{"key":"dc:title","label":"Title","values":["Utility of Digital Surgical Simulation Planning and Solid Free Form Modeling in Fibula Free Flap Mandibular Reconstruction"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wolfaardt, Johan (Medicine and Dentistry)"],"dc:contributor.other":["Jana Rieger (Speech Pathology and Audiology)","Hadi Seikaly (Medicine and Dentistry)","Bill Hodgetts (Speech Pathology and Audiology)","Pierre Boulanger (Computer Science)"],"dc:creator":["Logan, Heather Anne"],"dc:date.accessioned":["2025-05-28T22:01:16Z"],"dc:date.available":["2025-05-28T22:01:16Z"],"dc:date.issued":["2012-06"],"dc:description.abstract":["The purpose of the present study was to contribute to the growing body of knowledge and technical understanding of surgical design and simulation in fibula free flap mandibular reconstruction (FFFMR). The current study provided three key findings. (1) There was no statistically significant difference amongst the three CBCT machine warming times. There was, however, a statistically significant difference between Computerized Tomography (CT) scanning with 1mm slice thickness and CBCT scanning with 0.2mm slice thickness. (2) The convergent interview was an effective technique in collecting information about the perception of clinicians on the utility of virtual surgical planning and medical models in FFFMR. (3) Superimposed images produced in CAD software tools were helpful and effective in comparing pre and post-surgical outcomes, although there were a number of limitations in the programs. The exploratory benchtop study revealed that virtual surgical planning appeared to improve surgical performance and enhance consistency in accuracy."],"dc:identifier.doi":["https://doi.org/10.7939/R35M62F9W"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Mandibular Reconstruction","Surgical Design and Simulation","Rapid Prototyping","CT","CBCT","Medical Models","Fibula Free Flap","Convergent Interview","Digital Surgical Simulation"],"dc:title":["Utility of Digital Surgical Simulation Planning and Solid Free Form Modeling in Fibula Free Flap Mandibular Reconstruction"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:53:41Z"}