{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/78192"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/78192","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Charge transport in molecular junctions and microfluidic devices","abstract":"Electro-transmittance of molecular junctions was characterized electrically and studied optically at 410nm and 532nm. Between 1kHz and 100kHz there was no qualitative difference between the control samples and the molecular junction samples, however there were difficulties with reproducibility of the quantitative behaviour, so no hard conclusions could be drawn. A microfluidic capacitor device was designed and fabricated to study the electrical double layer, using standard microfabrication techniques. A complimentary flux corrected transport simulation was written using the same experimental geometry and the results of this study found qualitative agreement between the simulation and experiment. The experiment produced results about the concentration dependence of the double layer formation time which allows an estimate of the required frequency of an AC electrical signal for which the electrical double layer doesn’t have time to form, and its effects can be ignored.","abstract_html":"Electro-transmittance of molecular junctions was characterized electrically and studied optically at 410nm and 532nm. Between 1kHz and 100kHz there was no qualitative difference between the control samples and the molecular junction samples, however there were difficulties with reproducibility of the quantitative behaviour, so no hard conclusions could be drawn. A microfluidic capacitor device was designed and fabricated to study the electrical double layer, using standard microfabrication techniques. A complimentary flux corrected transport simulation was written using the same experimental geometry and the results of this study found qualitative agreement between the simulation and experiment. The experiment produced results about the concentration dependence of the double layer formation time which allows an estimate of the required frequency of an AC electrical signal for which the electrical double layer doesn’t have time to form, and its effects can be ignored.","abstract_has_math":false,"creators":["Olson, Steven"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Freeman, Mark (Physics)"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-11","date_published":"2010-11","updated_at":"2026-11-26T21:07:29Z","subjects":["Molecular junctions","Microfluidics","Charge transport"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3RQ7K","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3RQ7K","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F78192","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F78192","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Freeman, Mark (Physics)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Richard Sydora (Physics)","Richard McCreery (Chemistry)","Frank Marsiglio (Physics)"]},{"key":"dc:creator","label":"Author","values":["Olson, Steven"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-28T22:04:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-28T22:04:51Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Molecular junctions","Microfluidics","Charge transport"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3RQ7K"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Electro-transmittance of molecular junctions was characterized electrically and studied optically at 410nm and 532nm. Between 1kHz and 100kHz there was no qualitative difference between the control samples and the molecular junction samples, however there were difficulties with reproducibility of the quantitative behaviour, so no hard conclusions could be drawn. A microfluidic capacitor device was designed and fabricated to study the electrical double layer, using standard microfabrication techniques. A complimentary flux corrected transport simulation was written using the same experimental geometry and the results of this study found qualitative agreement between the simulation and experiment. The experiment produced results about the concentration dependence of the double layer formation time which allows an estimate of the required frequency of an AC electrical signal for which the electrical double layer doesn’t have time to form, and its effects can be ignored."]},{"key":"dc:title","label":"Title","values":["Charge transport in molecular junctions and microfluidic devices"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Freeman, Mark (Physics)"],"dc:contributor.other":["Richard Sydora (Physics)","Richard McCreery (Chemistry)","Frank Marsiglio (Physics)"],"dc:creator":["Olson, Steven"],"dc:date.accessioned":["2025-05-28T22:04:51Z"],"dc:date.available":["2025-05-28T22:04:51Z"],"dc:date.issued":["2010-11"],"dc:description.abstract":["Electro-transmittance of molecular junctions was characterized electrically and studied optically at 410nm and 532nm. Between 1kHz and 100kHz there was no qualitative difference between the control samples and the molecular junction samples, however there were difficulties with reproducibility of the quantitative behaviour, so no hard conclusions could be drawn. A microfluidic capacitor device was designed and fabricated to study the electrical double layer, using standard microfabrication techniques. A complimentary flux corrected transport simulation was written using the same experimental geometry and the results of this study found qualitative agreement between the simulation and experiment. The experiment produced results about the concentration dependence of the double layer formation time which allows an estimate of the required frequency of an AC electrical signal for which the electrical double layer doesn’t have time to form, and its effects can be ignored."],"dc:identifier.doi":["https://doi.org/10.7939/R3RQ7K"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Molecular junctions","Microfluidics","Charge transport"],"dc:title":["Charge transport in molecular junctions and microfluidic devices"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:07:29Z"}