{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/80689"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/80689","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Implementation of MR image-guided adaptive brachytherapy for cervix cancer","abstract":"Currently, the Cross Cancer Institute uses CT imaging in conjunction with the traditional Manchester system, which prescribes dose to a defined point, for cervix cancer brachytherapy. To take advantage of MRI for enhanced definition of soft tissue including the cancerous tissue itself, this thesis focuses on a study of MR image-guided cervix brachytherapy. Firstly, the geometric distortions of an applicator in an MR image and the accuracy of CT-MRI registration were quantitatively evaluated with a custom-made phantom, which provides one measure of the MRI distortion and indicates a CT-MRI registration method for cervix brachytherapy. The remaining part of the thesis describes an optimization method - simulated annealing (SA) - for automatically determining the dwell time configuration based on a set of specified dose-volume constraints. Application to a computer simulation model showed that SA was effective when the model structure sizes and distances are in a normal range. The effects on the optimization of different initial dwell times and a different initial number of dwell positions were also investigated. In general, optimization conformed dose to the target and significantly reduced dose to surrounding normal tissue.","abstract_html":"Currently, the Cross Cancer Institute uses CT imaging in conjunction with the traditional Manchester system, which prescribes dose to a defined point, for cervix cancer brachytherapy. To take advantage of MRI for enhanced definition of soft tissue including the cancerous tissue itself, this thesis focuses on a study of MR image-guided cervix brachytherapy. Firstly, the geometric distortions of an applicator in an MR image and the accuracy of CT-MRI registration were quantitatively evaluated with a custom-made phantom, which provides one measure of the MRI distortion and indicates a CT-MRI registration method for cervix brachytherapy. The remaining part of the thesis describes an optimization method - simulated annealing (SA) - for automatically determining the dwell time configuration based on a set of specified dose-volume constraints. Application to a computer simulation model showed that SA was effective when the model structure sizes and distances are in a normal range. The effects on the optimization of different initial dwell times and a different initial number of dwell positions were also investigated. In general, optimization conformed dose to the target and significantly reduced dose to surrounding normal tissue.","abstract_has_math":false,"creators":["Ren, Jiyun"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Sloboda, Ron (Oncology, Physics)","Menon, Geetha (Oncology)"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-11","date_published":"2011-11","updated_at":"2026-11-26T21:57:29Z","subjects":["CT-MRI fusion","Brachytherapy","Optimization","Cervix cancer"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R32S6P","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R32S6P","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F80689","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F80689","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sloboda, Ron (Oncology, Physics)","Menon, Geetha (Oncology)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Morsink, Sharon (Physics)","Fallone, Gino (Oncology, Physics)","Robinson, Don (Oncology, Physics)"]},{"key":"dc:creator","label":"Author","values":["Ren, Jiyun"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-28T23:36:25Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-28T23:36:25Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["CT-MRI fusion","Brachytherapy","Optimization","Cervix cancer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R32S6P"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Currently, the Cross Cancer Institute uses CT imaging in conjunction with the traditional Manchester system, which prescribes dose to a defined point, for cervix cancer brachytherapy. To take advantage of MRI for enhanced definition of soft tissue including the cancerous tissue itself, this thesis focuses on a study of MR image-guided cervix brachytherapy. Firstly, the geometric distortions of an applicator in an MR image and the accuracy of CT-MRI registration were quantitatively evaluated with a custom-made phantom, which provides one measure of the MRI distortion and indicates a CT-MRI registration method for cervix brachytherapy. The remaining part of the thesis describes an optimization method - simulated annealing (SA) - for automatically determining the dwell time configuration based on a set of specified dose-volume constraints. Application to a computer simulation model showed that SA was effective when the model structure sizes and distances are in a normal range. The effects on the optimization of different initial dwell times and a different initial number of dwell positions were also investigated. In general, optimization conformed dose to the target and significantly reduced dose to surrounding normal tissue."]},{"key":"dc:title","label":"Title","values":["Implementation of MR image-guided adaptive brachytherapy for cervix cancer"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sloboda, Ron (Oncology, Physics)","Menon, Geetha (Oncology)"],"dc:contributor.other":["Morsink, Sharon (Physics)","Fallone, Gino (Oncology, Physics)","Robinson, Don (Oncology, Physics)"],"dc:creator":["Ren, Jiyun"],"dc:date.accessioned":["2025-05-28T23:36:25Z"],"dc:date.available":["2025-05-28T23:36:25Z"],"dc:date.issued":["2011-11"],"dc:description.abstract":["Currently, the Cross Cancer Institute uses CT imaging in conjunction with the traditional Manchester system, which prescribes dose to a defined point, for cervix cancer brachytherapy. To take advantage of MRI for enhanced definition of soft tissue including the cancerous tissue itself, this thesis focuses on a study of MR image-guided cervix brachytherapy. Firstly, the geometric distortions of an applicator in an MR image and the accuracy of CT-MRI registration were quantitatively evaluated with a custom-made phantom, which provides one measure of the MRI distortion and indicates a CT-MRI registration method for cervix brachytherapy. The remaining part of the thesis describes an optimization method - simulated annealing (SA) - for automatically determining the dwell time configuration based on a set of specified dose-volume constraints. Application to a computer simulation model showed that SA was effective when the model structure sizes and distances are in a normal range. The effects on the optimization of different initial dwell times and a different initial number of dwell positions were also investigated. In general, optimization conformed dose to the target and significantly reduced dose to surrounding normal tissue."],"dc:identifier.doi":["https://doi.org/10.7939/R32S6P"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["CT-MRI fusion","Brachytherapy","Optimization","Cervix cancer"],"dc:title":["Implementation of MR image-guided adaptive brachytherapy for cervix cancer"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:57:29Z"}