{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/81535"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/81535","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Development and Evaluation of a Close-Proximity, Real Time Thermoacoustic Ultrasound Sensor","abstract":"A close proximity, real time thermoacoustic sensor was designed, tested, and implemented in the SonaCell ultrasound generator. When placed in contact with the SonaCell ultrasound transducer, a copper backed plexiglass absorber converted ultrasound energy into heat, where it was measured by a thermistor on the back face of the absorber. A transient model was used to calculated ultrasound intensity from temperature data by fitting the curve T_ave=C(1-e^((-t)/τ) )+ T_0 to the measured data using a least squares method and relating the coefficient C to the applied ultrasound intensity. Over an ultrasound intensity range of 30 mW/cm^2 to 100 mW/cm^2 the thermoacoustic sensor was able to calculate ultrasound intensities with an average error of 8.38% and a maximum observed standard deviation of 5.00 mW/cm^2 when compared to measurements made with a radiation force balance. Analysis of the model and a full evaluation of the designed sensor was carried out.","abstract_html":"A close proximity, real time thermoacoustic sensor was designed, tested, and implemented in the SonaCell ultrasound generator. When placed in contact with the SonaCell ultrasound transducer, a copper backed plexiglass absorber converted ultrasound energy into heat, where it was measured by a thermistor on the back face of the absorber. A transient model was used to calculated ultrasound intensity from temperature data by fitting the curve T_ave=C(1-e^((-t)/τ) )+ T_0 to the measured data using a least squares method and relating the coefficient C to the applied ultrasound intensity. Over an ultrasound intensity range of 30 mW/cm^2 to 100 mW/cm^2 the thermoacoustic sensor was able to calculate ultrasound intensities with an average error of 8.38% and a maximum observed standard deviation of 5.00 mW/cm^2 when compared to measurements made with a radiation force balance. Analysis of the model and a full evaluation of the designed sensor was carried out.","abstract_has_math":false,"creators":["Choi, Michael"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Chen, Jie (Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-06","date_published":"2012-06","updated_at":"2026-11-26T21:14:08Z","subjects":["Ultrasound Calibration","Ultrasound Sensor","Thermoacoustic Sensor"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3S91G","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3S91G","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F81535","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F81535","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Chen, Jie (Electrical and Computer Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Chen, Jie (Electrical and Computer Engineering)","Zemp, Roger (Electrical and Computer Engineering)","Cook, Al (Speech Pathology and Audiology)"]},{"key":"dc:creator","label":"Author","values":["Choi, Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T00:23:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T00:23:57Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ultrasound Calibration","Ultrasound Sensor","Thermoacoustic Sensor"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3S91G"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A close proximity, real time thermoacoustic sensor was designed, tested, and implemented in the SonaCell ultrasound generator. When placed in contact with the SonaCell ultrasound transducer, a copper backed plexiglass absorber converted ultrasound energy into heat, where it was measured by a thermistor on the back face of the absorber. A transient model was used to calculated ultrasound intensity from temperature data by fitting the curve T_ave=C(1-e^((-t)/τ) )+ T_0 to the measured data using a least squares method and relating the coefficient C to the applied ultrasound intensity. Over an ultrasound intensity range of 30 mW/cm^2 to 100 mW/cm^2 the thermoacoustic sensor was able to calculate ultrasound intensities with an average error of 8.38% and a maximum observed standard deviation of 5.00 mW/cm^2 when compared to measurements made with a radiation force balance. Analysis of the model and a full evaluation of the designed sensor was carried out."]},{"key":"dc:title","label":"Title","values":["Development and Evaluation of a Close-Proximity, Real Time Thermoacoustic Ultrasound Sensor"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Chen, Jie (Electrical and Computer Engineering)"],"dc:contributor.other":["Chen, Jie (Electrical and Computer Engineering)","Zemp, Roger (Electrical and Computer Engineering)","Cook, Al (Speech Pathology and Audiology)"],"dc:creator":["Choi, Michael"],"dc:date.accessioned":["2025-05-29T00:23:57Z"],"dc:date.available":["2025-05-29T00:23:57Z"],"dc:date.issued":["2012-06"],"dc:description.abstract":["A close proximity, real time thermoacoustic sensor was designed, tested, and implemented in the SonaCell ultrasound generator. When placed in contact with the SonaCell ultrasound transducer, a copper backed plexiglass absorber converted ultrasound energy into heat, where it was measured by a thermistor on the back face of the absorber. A transient model was used to calculated ultrasound intensity from temperature data by fitting the curve T_ave=C(1-e^((-t)/τ) )+ T_0 to the measured data using a least squares method and relating the coefficient C to the applied ultrasound intensity. Over an ultrasound intensity range of 30 mW/cm^2 to 100 mW/cm^2 the thermoacoustic sensor was able to calculate ultrasound intensities with an average error of 8.38% and a maximum observed standard deviation of 5.00 mW/cm^2 when compared to measurements made with a radiation force balance. Analysis of the model and a full evaluation of the designed sensor was carried out."],"dc:identifier.doi":["https://doi.org/10.7939/R3S91G"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Ultrasound Calibration","Ultrasound Sensor","Thermoacoustic Sensor"],"dc:title":["Development and Evaluation of a Close-Proximity, Real Time Thermoacoustic Ultrasound Sensor"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:14:08Z"}