{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/81765"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/81765","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Optimization of sodium MRI for the human knee at 4.7 tesla","abstract":"Osteoarthritis is characterized by pain and inflammation in joints, typically weight-bearing joints such as the knee. An early warning sign of osteoarthritis is the loss of proteoglycan molecules in the cartilage matrix. A surrogate method for measuring proteoglycan loss is detection of sodium ions, which ionically bond to negatively charged glycosaminoglycan side chains. Sodium MRI has the potential to non-invasively measure proteoglycan content, and hence act as a diagnostic tool for osteoarthritis. However, as sodium MRI suffers from low sodium concentrations in vivo and reduced MR sensitivity compared to standard proton MRI, techniques are required which optimize signal. This thesis examines the hardware, software, and acquisition techniques required in order to achieve high resolution, excellent quality sodium MR images of the human knee in vivo, which has potential applications in early diagnosis as well as pharmacological treatment evaluations of osteoarthritis.","abstract_html":"Osteoarthritis is characterized by pain and inflammation in joints, typically weight-bearing joints such as the knee. An early warning sign of osteoarthritis is the loss of proteoglycan molecules in the cartilage matrix. A surrogate method for measuring proteoglycan loss is detection of sodium ions, which ionically bond to negatively charged glycosaminoglycan side chains. Sodium MRI has the potential to non-invasively measure proteoglycan content, and hence act as a diagnostic tool for osteoarthritis. However, as sodium MRI suffers from low sodium concentrations in vivo and reduced MR sensitivity compared to standard proton MRI, techniques are required which optimize signal. This thesis examines the hardware, software, and acquisition techniques required in order to achieve high resolution, excellent quality sodium MR images of the human knee in vivo, which has potential applications in early diagnosis as well as pharmacological treatment evaluations of osteoarthritis.","abstract_has_math":false,"creators":["Watts, Alexander John"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Zemp, Roger (Electrical and Computer Engineering)","Beaulieu, Christian (Biomedical Engineering)"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-11","date_published":"2010-11","updated_at":"2026-11-26T21:17:57Z","subjects":["Human","Sodium","Osteoarthritis","Knee","MRI"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3NW2G","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3NW2G","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F81765","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F81765","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zemp, Roger (Electrical and Computer Engineering)","Beaulieu, Christian (Biomedical Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Lambert, Robert (Radiology, University of Alberta Hospital)","Thompson, Richard (Biomedical Engineering)"]},{"key":"dc:creator","label":"Author","values":["Watts, Alexander John"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T00:28:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T00:28:19Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Human","Sodium","Osteoarthritis","Knee","MRI"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3NW2G"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Osteoarthritis is characterized by pain and inflammation in joints, typically weight-bearing joints such as the knee. An early warning sign of osteoarthritis is the loss of proteoglycan molecules in the cartilage matrix. A surrogate method for measuring proteoglycan loss is detection of sodium ions, which ionically bond to negatively charged glycosaminoglycan side chains. Sodium MRI has the potential to non-invasively measure proteoglycan content, and hence act as a diagnostic tool for osteoarthritis. However, as sodium MRI suffers from low sodium concentrations in vivo and reduced MR sensitivity compared to standard proton MRI, techniques are required which optimize signal. This thesis examines the hardware, software, and acquisition techniques required in order to achieve high resolution, excellent quality sodium MR images of the human knee in vivo, which has potential applications in early diagnosis as well as pharmacological treatment evaluations of osteoarthritis."]},{"key":"dc:title","label":"Title","values":["Optimization of sodium MRI for the human knee at 4.7 tesla"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zemp, Roger (Electrical and Computer Engineering)","Beaulieu, Christian (Biomedical Engineering)"],"dc:contributor.other":["Lambert, Robert (Radiology, University of Alberta Hospital)","Thompson, Richard (Biomedical Engineering)"],"dc:creator":["Watts, Alexander John"],"dc:date.accessioned":["2025-05-29T00:28:19Z"],"dc:date.available":["2025-05-29T00:28:19Z"],"dc:date.issued":["2010-11"],"dc:description.abstract":["Osteoarthritis is characterized by pain and inflammation in joints, typically weight-bearing joints such as the knee. An early warning sign of osteoarthritis is the loss of proteoglycan molecules in the cartilage matrix. A surrogate method for measuring proteoglycan loss is detection of sodium ions, which ionically bond to negatively charged glycosaminoglycan side chains. Sodium MRI has the potential to non-invasively measure proteoglycan content, and hence act as a diagnostic tool for osteoarthritis. However, as sodium MRI suffers from low sodium concentrations in vivo and reduced MR sensitivity compared to standard proton MRI, techniques are required which optimize signal. This thesis examines the hardware, software, and acquisition techniques required in order to achieve high resolution, excellent quality sodium MR images of the human knee in vivo, which has potential applications in early diagnosis as well as pharmacological treatment evaluations of osteoarthritis."],"dc:identifier.doi":["https://doi.org/10.7939/R3NW2G"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Human","Sodium","Osteoarthritis","Knee","MRI"],"dc:title":["Optimization of sodium MRI for the human knee at 4.7 tesla"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:17:57Z"}