{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/82289"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/82289","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Refractometric sensing with fluorescent-core microcapillaries","abstract":"A capillary-type fluorescent-core microcavity refractive index sensor based on whispering gallery mode (WGM) resonances is presented. The device consists of a glass microcapillary with a thin layer of fluorescent silicon quantum dots (QDs) coated on the channel surface. The high index of the QD layer confines the electric field near the capillary channel and causes the development of WGMs in the fluorescence spectrum. Refractometric sensing was achieved in these fluorescent-core microcapillaries (FCMs) by pumping aqueous sucrose solutions through the capillary while measuring the fluorescence WGMs with a spectrometer. A finite-difference frequency-domain model was developed and used to study the performance of the FCMs. While the observed refractometric sensitivity and detection limit of the current device were inferior to competing technologies, FCMs offer other practical advantages, such as straight-forward fabrication, robust samples, and minimal instrumental requirements, all of which make FCMs an appealing technology for integration with lab-on-a-chip devices.","abstract_html":"A capillary-type fluorescent-core microcavity refractive index sensor based on whispering gallery mode (WGM) resonances is presented. The device consists of a glass microcapillary with a thin layer of fluorescent silicon quantum dots (QDs) coated on the channel surface. The high index of the QD layer confines the electric field near the capillary channel and causes the development of WGMs in the fluorescence spectrum. Refractometric sensing was achieved in these fluorescent-core microcapillaries (FCMs) by pumping aqueous sucrose solutions through the capillary while measuring the fluorescence WGMs with a spectrometer. A finite-difference frequency-domain model was developed and used to study the performance of the FCMs. While the observed refractometric sensitivity and detection limit of the current device were inferior to competing technologies, FCMs offer other practical advantages, such as straight-forward fabrication, robust samples, and minimal instrumental requirements, all of which make FCMs an appealing technology for integration with lab-on-a-chip devices.","abstract_has_math":false,"creators":["Manchee, Kyle"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Meldrum, Al (Physics)"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-11","date_published":"2011-11","updated_at":"2026-11-26T21:10:15Z","subjects":["All-optical devices","Microcavity devices","Resonators","Photoluminescence"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R34Q6M","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R34Q6M","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F82289","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F82289","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Meldrum, Al (Physics)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Freeman, Mark (Physics)","Veinot, Jonathan (Chemistry)","DeCorby, Ray (Electrical and Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Manchee, Kyle"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T00:41:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T00:41:58Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["All-optical devices","Microcavity devices","Resonators","Photoluminescence"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R34Q6M"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A capillary-type fluorescent-core microcavity refractive index sensor based on whispering gallery mode (WGM) resonances is presented. The device consists of a glass microcapillary with a thin layer of fluorescent silicon quantum dots (QDs) coated on the channel surface. The high index of the QD layer confines the electric field near the capillary channel and causes the development of WGMs in the fluorescence spectrum. Refractometric sensing was achieved in these fluorescent-core microcapillaries (FCMs) by pumping aqueous sucrose solutions through the capillary while measuring the fluorescence WGMs with a spectrometer. A finite-difference frequency-domain model was developed and used to study the performance of the FCMs. While the observed refractometric sensitivity and detection limit of the current device were inferior to competing technologies, FCMs offer other practical advantages, such as straight-forward fabrication, robust samples, and minimal instrumental requirements, all of which make FCMs an appealing technology for integration with lab-on-a-chip devices."]},{"key":"dc:title","label":"Title","values":["Refractometric sensing with fluorescent-core microcapillaries"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Meldrum, Al (Physics)"],"dc:contributor.other":["Freeman, Mark (Physics)","Veinot, Jonathan (Chemistry)","DeCorby, Ray (Electrical and Computer Engineering)"],"dc:creator":["Manchee, Kyle"],"dc:date.accessioned":["2025-05-29T00:41:58Z"],"dc:date.available":["2025-05-29T00:41:58Z"],"dc:date.issued":["2011-11"],"dc:description.abstract":["A capillary-type fluorescent-core microcavity refractive index sensor based on whispering gallery mode (WGM) resonances is presented. The device consists of a glass microcapillary with a thin layer of fluorescent silicon quantum dots (QDs) coated on the channel surface. The high index of the QD layer confines the electric field near the capillary channel and causes the development of WGMs in the fluorescence spectrum. Refractometric sensing was achieved in these fluorescent-core microcapillaries (FCMs) by pumping aqueous sucrose solutions through the capillary while measuring the fluorescence WGMs with a spectrometer. A finite-difference frequency-domain model was developed and used to study the performance of the FCMs. While the observed refractometric sensitivity and detection limit of the current device were inferior to competing technologies, FCMs offer other practical advantages, such as straight-forward fabrication, robust samples, and minimal instrumental requirements, all of which make FCMs an appealing technology for integration with lab-on-a-chip devices."],"dc:identifier.doi":["https://doi.org/10.7939/R34Q6M"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["All-optical devices","Microcavity devices","Resonators","Photoluminescence"],"dc:title":["Refractometric sensing with fluorescent-core microcapillaries"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:10:15Z"}