{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/82305"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/82305","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Performance of a Combination Heating System for Residential Applications","abstract":"Advancements in water heating and control technology have improved the performance of tankless water heaters in recent years. A tankless water heater coupled with a hydronic air-handling unit functions as a novel system known as a combination (“combo”) system that is used for residential space and water heating applications. However, the performance of such a system has not been well studied to date. In this thesis, an experimental method was developed to analyze the performance of the combo system for space heating only operation and simultaneous (space and water heating) operations. To quantify performance of the combo system, the effect of the outlet water temperature from the water heater and the effect of the flow rate of water for domestic usage on first law efficiency and hydronic heat exchanger second law efficiency were studied. With the experimental assembly, it was found that the thermal efficiency of the tankless water heater during space heating and simultaneous operation ranged between 39% and 95%. Two adverse behaviors, short-cycling and flow-cycling, were observed in the combination system operation and were found to have a negative impact on system efficiency. The hydronic heat exchanger exergy analysis results suggested that the combo system has comparable second law efficiencies when compared to other conventional hydronic space heaters. The results of the first and second law analyses suggest that combination systems have equivalent performance similar to mid- and high efficiency furnaces and conventional water heater units, provided that adequate control strategies are in place to optimize combination system operation.","abstract_html":"Advancements in water heating and control technology have improved the performance of tankless water heaters in recent years. A tankless water heater coupled with a hydronic air-handling unit functions as a novel system known as a combination (“combo”) system that is used for residential space and water heating applications. However, the performance of such a system has not been well studied to date. In this thesis, an experimental method was developed to analyze the performance of the combo system for space heating only operation and simultaneous (space and water heating) operations. To quantify performance of the combo system, the effect of the outlet water temperature from the water heater and the effect of the flow rate of water for domestic usage on first law efficiency and hydronic heat exchanger second law efficiency were studied. With the experimental assembly, it was found that the thermal efficiency of the tankless water heater during space heating and simultaneous operation ranged between 39% and 95%. Two adverse behaviors, short-cycling and flow-cycling, were observed in the combination system operation and were found to have a negative impact on system efficiency. The hydronic heat exchanger exergy analysis results suggested that the combo system has comparable second law efficiencies when compared to other conventional hydronic space heaters. The results of the first and second law analyses suggest that combination systems have equivalent performance similar to mid- and high efficiency furnaces and conventional water heater units, provided that adequate control strategies are in place to optimize combination system operation.","abstract_has_math":false,"creators":["Der, Joseph P."],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["McDonald, André (Mechanical Engineering)","Kostiuk, Larry (Mechanical Engineering)"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-11","date_published":"2016-11","updated_at":"2026-11-26T21:55:35Z","subjects":["Hydronic Air Handler System","Water Heating","Space Heating","Tankless Water Heater","Second Law Efficiency","Combination Heating System","First Law Efficiency","Integrated Heating System"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3Z892M0M","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3Z892M0M","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F82305","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F82305","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["McDonald, André (Mechanical Engineering)","Kostiuk, Larry (Mechanical Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Chen, Yuxiang (Civil and Environmental Engineering)"]},{"key":"dc:creator","label":"Author","values":["Der, Joseph P."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T00:42:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T00:42:27Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Hydronic Air Handler System","Water Heating","Space Heating","Tankless Water Heater","Second Law Efficiency","Combination Heating System","First Law Efficiency","Integrated Heating System"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3Z892M0M"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Advancements in water heating and control technology have improved the performance of tankless water heaters in recent years. A tankless water heater coupled with a hydronic air-handling unit functions as a novel system known as a combination (“combo”) system that is used for residential space and water heating applications. However, the performance of such a system has not been well studied to date. In this thesis, an experimental method was developed to analyze the performance of the combo system for space heating only operation and simultaneous (space and water heating) operations. To quantify performance of the combo system, the effect of the outlet water temperature from the water heater and the effect of the flow rate of water for domestic usage on first law efficiency and hydronic heat exchanger second law efficiency were studied. With the experimental assembly, it was found that the thermal efficiency of the tankless water heater during space heating and simultaneous operation ranged between 39% and 95%. Two adverse behaviors, short-cycling and flow-cycling, were observed in the combination system operation and were found to have a negative impact on system efficiency. The hydronic heat exchanger exergy analysis results suggested that the combo system has comparable second law efficiencies when compared to other conventional hydronic space heaters. The results of the first and second law analyses suggest that combination systems have equivalent performance similar to mid- and high efficiency furnaces and conventional water heater units, provided that adequate control strategies are in place to optimize combination system operation."]},{"key":"dc:title","label":"Title","values":["Performance of a Combination Heating System for Residential Applications"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["McDonald, André (Mechanical Engineering)","Kostiuk, Larry (Mechanical Engineering)"],"dc:contributor.other":["Chen, Yuxiang (Civil and Environmental Engineering)"],"dc:creator":["Der, Joseph P."],"dc:date.accessioned":["2025-05-29T00:42:27Z"],"dc:date.available":["2025-05-29T00:42:27Z"],"dc:date.issued":["2016-11"],"dc:description.abstract":["Advancements in water heating and control technology have improved the performance of tankless water heaters in recent years. A tankless water heater coupled with a hydronic air-handling unit functions as a novel system known as a combination (“combo”) system that is used for residential space and water heating applications. However, the performance of such a system has not been well studied to date. In this thesis, an experimental method was developed to analyze the performance of the combo system for space heating only operation and simultaneous (space and water heating) operations. To quantify performance of the combo system, the effect of the outlet water temperature from the water heater and the effect of the flow rate of water for domestic usage on first law efficiency and hydronic heat exchanger second law efficiency were studied. With the experimental assembly, it was found that the thermal efficiency of the tankless water heater during space heating and simultaneous operation ranged between 39% and 95%. Two adverse behaviors, short-cycling and flow-cycling, were observed in the combination system operation and were found to have a negative impact on system efficiency. The hydronic heat exchanger exergy analysis results suggested that the combo system has comparable second law efficiencies when compared to other conventional hydronic space heaters. The results of the first and second law analyses suggest that combination systems have equivalent performance similar to mid- and high efficiency furnaces and conventional water heater units, provided that adequate control strategies are in place to optimize combination system operation."],"dc:identifier.doi":["https://doi.org/10.7939/R3Z892M0M"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Hydronic Air Handler System","Water Heating","Space Heating","Tankless Water Heater","Second Law Efficiency","Combination Heating System","First Law Efficiency","Integrated Heating System"],"dc:title":["Performance of a Combination Heating System for Residential Applications"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:55:35Z"}