{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/85650"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/85650","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Quantitative Photoacoustic Imaging","abstract":"Tumor angiogenesis is the cancer-induced chaotic proliferation of blood vessel structure penetrating into surrounding cancerous tissue. Effective micro-vasculature imaging method is urgently desired for both fundamental biological and clinical studies. However, this is a challenging task, as existing standard imaging techniques are limited by factors such as poor resolution, high cost, necessity of using imaging contrast agent and invasiveness. Photoacoustic (PA) imaging, as a non-ionizing modality, has drawn significant interest due to the promise it holds for high-resolution, noninvasiveness and its capability to reveal functional information based on intrinsic optical contrast. The ultimate goal of this dissertation is to further previous work on quantitative photoacoustic imaging, specifically, to contribute to quantitative imaging of tumor angiogenesis and anti-angiogenetic therapy. The work presented in this dissertation can be divided into three parts. In the first part, we focus on quantitative photoacoutic tomography (qPAT) for deep tissue imaging. We developed a series of algorithms that are able to quantify deep tissue photoacoustic imaging. We demonstrated by simulations that spatial distributions of optical properties, namely optical absorption and scattering, as well as the Grüneisen parameter can be faithfully reconstructed with our reconstruction algorithms. In the second part, we focused on developing new imaging platforms for quantitative photoacoustic microscopy (PAM) imaging for superficial imaging depths. We successfully included fluorescently-labeled molecular context in optical-resolution PAM (OR-PAM) imaging by our integrated micro-endoscopy system that is able to simultaneously accomplish fluorescence and OR-PAM imaging. With our fast, wide field-of-view OR-PAM imaging technique, we significantly reduced the data acquisition time of conventional OR-PAM systems to a clinically realistic level. In the third part, experimental work is presented for quantitative imaging of vasculature variations and oxygen depletions due to photodynamic therapy with an acoustic-resolution PAM (AR-PAM) system we developed.","abstract_html":"Tumor angiogenesis is the cancer-induced chaotic proliferation of blood vessel structure penetrating into surrounding cancerous tissue. Effective micro-vasculature imaging method is urgently desired for both fundamental biological and clinical studies. However, this is a challenging task, as existing standard imaging techniques are limited by factors such as poor resolution, high cost, necessity of using imaging contrast agent and invasiveness. Photoacoustic (PA) imaging, as a non-ionizing modality, has drawn significant interest due to the promise it holds for high-resolution, noninvasiveness and its capability to reveal functional information based on intrinsic optical contrast. The ultimate goal of this dissertation is to further previous work on quantitative photoacoustic imaging, specifically, to contribute to quantitative imaging of tumor angiogenesis and anti-angiogenetic therapy. The work presented in this dissertation can be divided into three parts. In the first part, we focus on quantitative photoacoutic tomography (qPAT) for deep tissue imaging. We developed a series of algorithms that are able to quantify deep tissue photoacoustic imaging. We demonstrated by simulations that spatial distributions of optical properties, namely optical absorption and scattering, as well as the Grüneisen parameter can be faithfully reconstructed with our reconstruction algorithms. In the second part, we focused on developing new imaging platforms for quantitative photoacoustic microscopy (PAM) imaging for superficial imaging depths. We successfully included fluorescently-labeled molecular context in optical-resolution PAM (OR-PAM) imaging by our integrated micro-endoscopy system that is able to simultaneously accomplish fluorescence and OR-PAM imaging. With our fast, wide field-of-view OR-PAM imaging technique, we significantly reduced the data acquisition time of conventional OR-PAM systems to a clinically realistic level. In the third part, experimental work is presented for quantitative imaging of vasculature variations and oxygen depletions due to photodynamic therapy with an acoustic-resolution PAM (AR-PAM) system we developed.","abstract_has_math":false,"creators":["Shao, Peng"],"institution":"University of Alberta","degree_name":"Doctor of Philosophy","degree_level":"Doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Zemp, Roger James(Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-11","date_published":"2014-11","updated_at":"2026-11-26T20:57:39Z","subjects":["Quantitative","Photoacoustic tomography","Photodynamic therapy","Photoacoustic microscopy"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3ZK55T23","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3ZK55T23","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F85650","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F85650","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zemp, Roger James(Electrical and Computer Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Tang, Shuo(Electrical and Computer Engineering, University of British Columbia)","Van, Vien(Electrical and Computer Engineering)","Tavakoli, Mahdi(Electrical and Computer Engineering)","Mandal, Mrinal(Electrical and Computer Engineering)","Fedosejevs,Robert(Electrical and Computer Engineering)","Shankar, Karthik(Electrical and Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Shao, Peng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T03:02:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T03:02:30Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Quantitative","Photoacoustic tomography","Photodynamic therapy","Photoacoustic microscopy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3ZK55T23"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Tumor angiogenesis is the cancer-induced chaotic proliferation of blood vessel structure penetrating into surrounding cancerous tissue. Effective micro-vasculature imaging method is urgently desired for both fundamental biological and clinical studies. However, this is a challenging task, as existing standard imaging techniques are limited by factors such as poor resolution, high cost, necessity of using imaging contrast agent and invasiveness. Photoacoustic (PA) imaging, as a non-ionizing modality, has drawn significant interest due to the promise it holds for high-resolution, noninvasiveness and its capability to reveal functional information based on intrinsic optical contrast. The ultimate goal of this dissertation is to further previous work on quantitative photoacoustic imaging, specifically, to contribute to quantitative imaging of tumor angiogenesis and anti-angiogenetic therapy. The work presented in this dissertation can be divided into three parts. In the first part, we focus on quantitative photoacoutic tomography (qPAT) for deep tissue imaging. We developed a series of algorithms that are able to quantify deep tissue photoacoustic imaging. We demonstrated by simulations that spatial distributions of optical properties, namely optical absorption and scattering, as well as the Grüneisen parameter can be faithfully reconstructed with our reconstruction algorithms. In the second part, we focused on developing new imaging platforms for quantitative photoacoustic microscopy (PAM) imaging for superficial imaging depths. We successfully included fluorescently-labeled molecular context in optical-resolution PAM (OR-PAM) imaging by our integrated micro-endoscopy system that is able to simultaneously accomplish fluorescence and OR-PAM imaging. With our fast, wide field-of-view OR-PAM imaging technique, we significantly reduced the data acquisition time of conventional OR-PAM systems to a clinically realistic level. In the third part, experimental work is presented for quantitative imaging of vasculature variations and oxygen depletions due to photodynamic therapy with an acoustic-resolution PAM (AR-PAM) system we developed."]},{"key":"dc:title","label":"Title","values":["Quantitative Photoacoustic Imaging"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zemp, Roger James(Electrical and Computer Engineering)"],"dc:contributor.other":["Tang, Shuo(Electrical and Computer Engineering, University of British Columbia)","Van, Vien(Electrical and Computer Engineering)","Tavakoli, Mahdi(Electrical and Computer Engineering)","Mandal, Mrinal(Electrical and Computer Engineering)","Fedosejevs,Robert(Electrical and Computer Engineering)","Shankar, Karthik(Electrical and Computer Engineering)"],"dc:creator":["Shao, Peng"],"dc:date.accessioned":["2025-05-29T03:02:30Z"],"dc:date.available":["2025-05-29T03:02:30Z"],"dc:date.issued":["2014-11"],"dc:description.abstract":["Tumor angiogenesis is the cancer-induced chaotic proliferation of blood vessel structure penetrating into surrounding cancerous tissue. Effective micro-vasculature imaging method is urgently desired for both fundamental biological and clinical studies. However, this is a challenging task, as existing standard imaging techniques are limited by factors such as poor resolution, high cost, necessity of using imaging contrast agent and invasiveness. Photoacoustic (PA) imaging, as a non-ionizing modality, has drawn significant interest due to the promise it holds for high-resolution, noninvasiveness and its capability to reveal functional information based on intrinsic optical contrast. The ultimate goal of this dissertation is to further previous work on quantitative photoacoustic imaging, specifically, to contribute to quantitative imaging of tumor angiogenesis and anti-angiogenetic therapy. The work presented in this dissertation can be divided into three parts. In the first part, we focus on quantitative photoacoutic tomography (qPAT) for deep tissue imaging. We developed a series of algorithms that are able to quantify deep tissue photoacoustic imaging. We demonstrated by simulations that spatial distributions of optical properties, namely optical absorption and scattering, as well as the Grüneisen parameter can be faithfully reconstructed with our reconstruction algorithms. In the second part, we focused on developing new imaging platforms for quantitative photoacoustic microscopy (PAM) imaging for superficial imaging depths. We successfully included fluorescently-labeled molecular context in optical-resolution PAM (OR-PAM) imaging by our integrated micro-endoscopy system that is able to simultaneously accomplish fluorescence and OR-PAM imaging. With our fast, wide field-of-view OR-PAM imaging technique, we significantly reduced the data acquisition time of conventional OR-PAM systems to a clinically realistic level. In the third part, experimental work is presented for quantitative imaging of vasculature variations and oxygen depletions due to photodynamic therapy with an acoustic-resolution PAM (AR-PAM) system we developed."],"dc:identifier.doi":["https://doi.org/10.7939/R3ZK55T23"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Quantitative","Photoacoustic tomography","Photodynamic therapy","Photoacoustic microscopy"],"dc:title":["Quantitative Photoacoustic Imaging"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T20:57:39Z"}