{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/86287"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/86287","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Geothermics of the Phanerozoic strata of Saskatchewan","abstract":"New data and revised processing methods yielded a revised understanding of the geothermics of the Phanerozoic strata in Saskatchewan. Temperatures increase with depth from 5 °C at 100 m to 120 °C at 3200 m. Average integral geothermal gradients range between 25 and 30 °C•km-1. Geothermal gradients are higher than average between the Cypress Hills and Swift Current; in the Weyburn-Estevan area; and at Yorkton. Anomalously cold areas are present near the Alberta border and at Saskatoon. Hot anomalies are present due to excess basement heat generation, the insulating effect of low thermal conductivity shale packages, and topographic effects. Colder than average areas coincide with areas of low heat flow. No extremely high geothermal gradients (>50 °C•km-1) or significant vertical heat flow differences (>10 mW•m-2) exist along the outcrop edge, therefore heat conduction is considered the main heat transfer method in the basin.","abstract_html":"New data and revised processing methods yielded a revised understanding of the geothermics of the Phanerozoic strata in Saskatchewan. Temperatures increase with depth from 5 °C at 100 m to 120 °C at 3200 m. Average integral geothermal gradients range between 25 and 30 °C•km-1. Geothermal gradients are higher than average between the Cypress Hills and Swift Current; in the Weyburn-Estevan area; and at Yorkton. Anomalously cold areas are present near the Alberta border and at Saskatoon. Hot anomalies are present due to excess basement heat generation, the insulating effect of low thermal conductivity shale packages, and topographic effects. Colder than average areas coincide with areas of low heat flow. No extremely high geothermal gradients (&gt;50 °C•km-1) or significant vertical heat flow differences (&gt;10 mW•m-2) exist along the outcrop edge, therefore heat conduction is considered the main heat transfer method in the basin.","abstract_has_math":false,"creators":["Lengyel, Tibor"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Ben Rostron, Department of Earth and Atmospheric Sciences"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-11","date_published":"2013-11","updated_at":"2026-11-26T21:01:54Z","subjects":["Heat flow","Quality control","Geothermics","Saskatchewan","Geothermal gradient"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3RB6WC8Z","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3RB6WC8Z","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F86287","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F86287","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ben Rostron, Department of Earth and Atmospheric Sciences"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Ben Rostron, Department of Earth and Atmospheric Sciences","Inga Moeck, Department of Earth and Atmospheric Sciences","Carl Mendoza, Department of Earth and Atmospheric Sciences"]},{"key":"dc:creator","label":"Author","values":["Lengyel, Tibor"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T03:18:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T03:18:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Heat flow","Quality control","Geothermics","Saskatchewan","Geothermal gradient"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3RB6WC8Z"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["New data and revised processing methods yielded a revised understanding of the geothermics of the Phanerozoic strata in Saskatchewan. Temperatures increase with depth from 5 °C at 100 m to 120 °C at 3200 m. Average integral geothermal gradients range between 25 and 30 °C•km-1. Geothermal gradients are higher than average between the Cypress Hills and Swift Current; in the Weyburn-Estevan area; and at Yorkton. Anomalously cold areas are present near the Alberta border and at Saskatoon. Hot anomalies are present due to excess basement heat generation, the insulating effect of low thermal conductivity shale packages, and topographic effects. Colder than average areas coincide with areas of low heat flow. No extremely high geothermal gradients (>50 °C•km-1) or significant vertical heat flow differences (>10 mW•m-2) exist along the outcrop edge, therefore heat conduction is considered the main heat transfer method in the basin."]},{"key":"dc:title","label":"Title","values":["Geothermics of the Phanerozoic strata of Saskatchewan"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ben Rostron, Department of Earth and Atmospheric Sciences"],"dc:contributor.other":["Ben Rostron, Department of Earth and Atmospheric Sciences","Inga Moeck, Department of Earth and Atmospheric Sciences","Carl Mendoza, Department of Earth and Atmospheric Sciences"],"dc:creator":["Lengyel, Tibor"],"dc:date.accessioned":["2025-05-29T03:18:13Z"],"dc:date.available":["2025-05-29T03:18:13Z"],"dc:date.issued":["2013-11"],"dc:description.abstract":["New data and revised processing methods yielded a revised understanding of the geothermics of the Phanerozoic strata in Saskatchewan. Temperatures increase with depth from 5 °C at 100 m to 120 °C at 3200 m. Average integral geothermal gradients range between 25 and 30 °C•km-1. Geothermal gradients are higher than average between the Cypress Hills and Swift Current; in the Weyburn-Estevan area; and at Yorkton. Anomalously cold areas are present near the Alberta border and at Saskatoon. Hot anomalies are present due to excess basement heat generation, the insulating effect of low thermal conductivity shale packages, and topographic effects. Colder than average areas coincide with areas of low heat flow. No extremely high geothermal gradients (>50 °C•km-1) or significant vertical heat flow differences (>10 mW•m-2) exist along the outcrop edge, therefore heat conduction is considered the main heat transfer method in the basin."],"dc:identifier.doi":["https://doi.org/10.7939/R3RB6WC8Z"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Heat flow","Quality control","Geothermics","Saskatchewan","Geothermal gradient"],"dc:title":["Geothermics of the Phanerozoic strata of Saskatchewan"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:01:54Z"}