{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/87276"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/87276","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Perfusion-Rate Estimation Using Ultrafast Speckle-Decorrelation Ultrasound Imaging","abstract":"Estimating tissue perfusion has great clinical applications such as the prediction of anti-angiogenic therapies and stroke management. Ultrasound perfusion imaging is preferable than other methods since it has real time capabilities, and it is inexpensive. The method proposed in this study shows the relationship between tissue perfusion and speckle decorrelation rate when high-frequency, high-frame rate ultrasound is used. We also investigated the use of lower frequency ultrasound transducers with high-frame rate, plane wave compounding imaging, and the results are promising. This new approach to estimate tissue perfusion waves the need for contrast agents while providing quantitative information on tissue perfusion (consequently, outperforming PD imaging) as well as morphological information. We combined adaptive block-wise SVD filter, AM2D algorithm for tissue motion compensation and Golay sequences to substantially increase the SNR and therefore increase perfusion sensitivity with the ultimate goal of proving the robustness of this new method and its capability to being used in clinical applications.","abstract_html":"Estimating tissue perfusion has great clinical applications such as the prediction of anti-angiogenic therapies and stroke management. Ultrasound perfusion imaging is preferable than other methods since it has real time capabilities, and it is inexpensive. The method proposed in this study shows the relationship between tissue perfusion and speckle decorrelation rate when high-frequency, high-frame rate ultrasound is used. We also investigated the use of lower frequency ultrasound transducers with high-frame rate, plane wave compounding imaging, and the results are promising. This new approach to estimate tissue perfusion waves the need for contrast agents while providing quantitative information on tissue perfusion (consequently, outperforming PD imaging) as well as morphological information. We combined adaptive block-wise SVD filter, AM2D algorithm for tissue motion compensation and Golay sequences to substantially increase the SNR and therefore increase perfusion sensitivity with the ultimate goal of proving the robustness of this new method and its capability to being used in clinical applications.","abstract_has_math":false,"creators":["Nascimento de Oliveira, Mayara"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Zemp, Roger (Electrical and Computer Engineering, Biomedical Engineering)"],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-11","date_published":"2022-11","updated_at":"2026-11-26T21:05:12Z","subjects":["Tissue perfusion","Ultrasound Imaging","Photoacoustic Imaging","Image Processing"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/r3-a4yt-c707","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/r3-a4yt-c707","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F87276","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F87276","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zemp, Roger (Electrical and Computer Engineering, Biomedical Engineering)"]},{"key":"dc:creator","label":"Author","values":["Nascimento de Oliveira, Mayara"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T06:55:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T06:55:43Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Tissue perfusion","Ultrasound Imaging","Photoacoustic Imaging","Image Processing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/r3-a4yt-c707"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Estimating tissue perfusion has great clinical applications such as the prediction of anti-angiogenic therapies and stroke management. Ultrasound perfusion imaging is preferable than other methods since it has real time capabilities, and it is inexpensive. The method proposed in this study shows the relationship between tissue perfusion and speckle decorrelation rate when high-frequency, high-frame rate ultrasound is used. We also investigated the use of lower frequency ultrasound transducers with high-frame rate, plane wave compounding imaging, and the results are promising. This new approach to estimate tissue perfusion waves the need for contrast agents while providing quantitative information on tissue perfusion (consequently, outperforming PD imaging) as well as morphological information. We combined adaptive block-wise SVD filter, AM2D algorithm for tissue motion compensation and Golay sequences to substantially increase the SNR and therefore increase perfusion sensitivity with the ultimate goal of proving the robustness of this new method and its capability to being used in clinical applications."]},{"key":"dc:title","label":"Title","values":["Perfusion-Rate Estimation Using Ultrafast Speckle-Decorrelation Ultrasound Imaging"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zemp, Roger (Electrical and Computer Engineering, Biomedical Engineering)"],"dc:creator":["Nascimento de Oliveira, Mayara"],"dc:date.accessioned":["2025-05-29T06:55:43Z"],"dc:date.available":["2025-05-29T06:55:43Z"],"dc:date.issued":["2022-11"],"dc:description.abstract":["Estimating tissue perfusion has great clinical applications such as the prediction of anti-angiogenic therapies and stroke management. Ultrasound perfusion imaging is preferable than other methods since it has real time capabilities, and it is inexpensive. The method proposed in this study shows the relationship between tissue perfusion and speckle decorrelation rate when high-frequency, high-frame rate ultrasound is used. We also investigated the use of lower frequency ultrasound transducers with high-frame rate, plane wave compounding imaging, and the results are promising. This new approach to estimate tissue perfusion waves the need for contrast agents while providing quantitative information on tissue perfusion (consequently, outperforming PD imaging) as well as morphological information. We combined adaptive block-wise SVD filter, AM2D algorithm for tissue motion compensation and Golay sequences to substantially increase the SNR and therefore increase perfusion sensitivity with the ultimate goal of proving the robustness of this new method and its capability to being used in clinical applications."],"dc:identifier.doi":["https://doi.org/10.7939/r3-a4yt-c707"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Tissue perfusion","Ultrasound Imaging","Photoacoustic Imaging","Image Processing"],"dc:title":["Perfusion-Rate Estimation Using Ultrafast Speckle-Decorrelation Ultrasound Imaging"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:05:12Z"}