{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/87655"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/87655","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Application of Ultrasound to Guide Pedicle Screw Insertion during Scoliosis Surgery: a Feasibility Study","abstract":"This thesis presents an experimental study of a bovine vertebra using transmission and pulse-echo methods and a preliminary investigation to guide a screw insertion into a pedicle using TomoScan phased array unit. The results show the cancellous bone has higher attenuation than the cortical bone for 1.0-5.0 MHz. The optimal frequencies for imaging are found to be 3.5 and 5.0 MHz. When the sample is filled with water with the cancellous core removed, all reflections from the layers and screw are visible; however when the core is present, only reflections from the top cortex are identifiable. For the preliminary study, size and placement of the transducer array are important. When the ultrasound beam is normal to the pedicle surface, echoes from the pedicle layers and the steel bit are strong; otherwise, signals are weak and not even identifiable. Larger aperture size will enhance the signal-to-noise ratio but deteriorate lateral resolution.","abstract_html":"This thesis presents an experimental study of a bovine vertebra using transmission and pulse-echo methods and a preliminary investigation to guide a screw insertion into a pedicle using TomoScan phased array unit. The results show the cancellous bone has higher attenuation than the cortical bone for 1.0-5.0 MHz. The optimal frequencies for imaging are found to be 3.5 and 5.0 MHz. When the sample is filled with water with the cancellous core removed, all reflections from the layers and screw are visible; however when the core is present, only reflections from the top cortex are identifiable. For the preliminary study, size and placement of the transducer array are important. When the ultrasound beam is normal to the pedicle surface, echoes from the pedicle layers and the steel bit are strong; otherwise, signals are weak and not even identifiable. Larger aperture size will enhance the signal-to-noise ratio but deteriorate lateral resolution.","abstract_has_math":false,"creators":["Zhang, Chan"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Le, Lawrence H. (Radiology and Diagnostic Imaging)","Lou, Edmond(Electronic and Computer Engineering)"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-06","date_published":"2011-06","updated_at":"2026-11-26T21:55:17Z","subjects":["Ultrasound","Bone Imaging","Scoliosis Surgery"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R30C79","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R30C79","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F87655","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F87655","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Le, Lawrence H. (Radiology and Diagnostic Imaging)","Lou, Edmond(Electronic and Computer Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Lou, Edmond(Electronic and Computer Engineering)","Filipow, Larry (Radiology and Diagnostic Imaging)","Le, Lawrence (Radiology and Diagnostic Imaging)"]},{"key":"dc:creator","label":"Author","values":["Zhang, Chan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T07:01:44Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T07:01:44Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ultrasound","Bone Imaging","Scoliosis Surgery"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R30C79"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents an experimental study of a bovine vertebra using transmission and pulse-echo methods and a preliminary investigation to guide a screw insertion into a pedicle using TomoScan phased array unit. The results show the cancellous bone has higher attenuation than the cortical bone for 1.0-5.0 MHz. The optimal frequencies for imaging are found to be 3.5 and 5.0 MHz. When the sample is filled with water with the cancellous core removed, all reflections from the layers and screw are visible; however when the core is present, only reflections from the top cortex are identifiable. For the preliminary study, size and placement of the transducer array are important. When the ultrasound beam is normal to the pedicle surface, echoes from the pedicle layers and the steel bit are strong; otherwise, signals are weak and not even identifiable. Larger aperture size will enhance the signal-to-noise ratio but deteriorate lateral resolution."]},{"key":"dc:title","label":"Title","values":["Application of Ultrasound to Guide Pedicle Screw Insertion during Scoliosis Surgery: a Feasibility Study"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Le, Lawrence H. (Radiology and Diagnostic Imaging)","Lou, Edmond(Electronic and Computer Engineering)"],"dc:contributor.other":["Lou, Edmond(Electronic and Computer Engineering)","Filipow, Larry (Radiology and Diagnostic Imaging)","Le, Lawrence (Radiology and Diagnostic Imaging)"],"dc:creator":["Zhang, Chan"],"dc:date.accessioned":["2025-05-29T07:01:44Z"],"dc:date.available":["2025-05-29T07:01:44Z"],"dc:date.issued":["2011-06"],"dc:description.abstract":["This thesis presents an experimental study of a bovine vertebra using transmission and pulse-echo methods and a preliminary investigation to guide a screw insertion into a pedicle using TomoScan phased array unit. The results show the cancellous bone has higher attenuation than the cortical bone for 1.0-5.0 MHz. The optimal frequencies for imaging are found to be 3.5 and 5.0 MHz. When the sample is filled with water with the cancellous core removed, all reflections from the layers and screw are visible; however when the core is present, only reflections from the top cortex are identifiable. For the preliminary study, size and placement of the transducer array are important. When the ultrasound beam is normal to the pedicle surface, echoes from the pedicle layers and the steel bit are strong; otherwise, signals are weak and not even identifiable. Larger aperture size will enhance the signal-to-noise ratio but deteriorate lateral resolution."],"dc:identifier.doi":["https://doi.org/10.7939/R30C79"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Ultrasound","Bone Imaging","Scoliosis Surgery"],"dc:title":["Application of Ultrasound to Guide Pedicle Screw Insertion during Scoliosis Surgery: a Feasibility Study"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:55:17Z"}