{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/89494"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/89494","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Steam Regeneration of Amine Impregnated Silica Based Sorbents for Post Combustion CO2 Capture","abstract":"In this study, an experimental investigation of CO2 capture using amine functionalized mesoporous silica based sorbents was carried out. Polyethyleneimine (PEI) impregnated silica sorbents were synthesized and tested in TGA under different adsorption temperatures and partial pressures of CO2. Sorbent characterization was carried out using N2 adsorption-desorption isotherms, FTIR, SEM and elemental analysis. Multiple cycles study was conducted to examine the effect of presence of O2 (0-5%) in flue gas on CO2 adsorption performance of sorbent. A separate packed bed study was conducted to study the effect of different concentrations of moisture (5.27–14.74%) in flue gas on CO2 adsorption and energy requirements for sorbent regeneration. A major study that was undertaken was to test the performance and stability of sorbent under steam stripping conditions. Steam was used for sorbent regeneration in a multiple cycle study and characterization of used sample was carried out to study any change in sorbent properties. Steam at different temperatures was used to study CO2 desorption. Desorption kinetics for steam and inert gas stripping was compared. It was observed that the sorbent performance was stable under steam environment along with improved desorption kinetics over inert gas stripping. No steam condensation or amine leaching was observed in this study.","abstract_html":"In this study, an experimental investigation of CO2 capture using amine functionalized mesoporous silica based sorbents was carried out. Polyethyleneimine (PEI) impregnated silica sorbents were synthesized and tested in TGA under different adsorption temperatures and partial pressures of CO2. Sorbent characterization was carried out using N2 adsorption-desorption isotherms, FTIR, SEM and elemental analysis. Multiple cycles study was conducted to examine the effect of presence of O2 (0-5%) in flue gas on CO2 adsorption performance of sorbent. A separate packed bed study was conducted to study the effect of different concentrations of moisture (5.27–14.74%) in flue gas on CO2 adsorption and energy requirements for sorbent regeneration. A major study that was undertaken was to test the performance and stability of sorbent under steam stripping conditions. Steam was used for sorbent regeneration in a multiple cycle study and characterization of used sample was carried out to study any change in sorbent properties. Steam at different temperatures was used to study CO2 desorption. Desorption kinetics for steam and inert gas stripping was compared. It was observed that the sorbent performance was stable under steam environment along with improved desorption kinetics over inert gas stripping. No steam condensation or amine leaching was observed in this study.","abstract_has_math":false,"creators":["Sandhu, Navjot Kaur"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Gupta, Rajender (Chemical and Materials Engineering)"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-11","date_published":"2014-11","updated_at":"2026-11-26T21:02:17Z","subjects":["Post combustion CO2 Capture","Polyethyleneimine","Solid sorbent","Steam regeneration"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R37W67C5H","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R37W67C5H","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F89494","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F89494","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gupta, Rajender (Chemical and Materials Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Hashisho, Zaher (Civil and Environmental Engineering)","Gupta, Rajender (Chemical and Materials Engineering)","Rajendran, Arvind (Chemical and Materials Engineering)"]},{"key":"dc:creator","label":"Author","values":["Sandhu, Navjot Kaur"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T08:19:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T08:19:38Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Post combustion CO2 Capture","Polyethyleneimine","Solid sorbent","Steam regeneration"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R37W67C5H"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this study, an experimental investigation of CO2 capture using amine functionalized mesoporous silica based sorbents was carried out. Polyethyleneimine (PEI) impregnated silica sorbents were synthesized and tested in TGA under different adsorption temperatures and partial pressures of CO2. Sorbent characterization was carried out using N2 adsorption-desorption isotherms, FTIR, SEM and elemental analysis. Multiple cycles study was conducted to examine the effect of presence of O2 (0-5%) in flue gas on CO2 adsorption performance of sorbent. A separate packed bed study was conducted to study the effect of different concentrations of moisture (5.27–14.74%) in flue gas on CO2 adsorption and energy requirements for sorbent regeneration. A major study that was undertaken was to test the performance and stability of sorbent under steam stripping conditions. Steam was used for sorbent regeneration in a multiple cycle study and characterization of used sample was carried out to study any change in sorbent properties. Steam at different temperatures was used to study CO2 desorption. Desorption kinetics for steam and inert gas stripping was compared. It was observed that the sorbent performance was stable under steam environment along with improved desorption kinetics over inert gas stripping. No steam condensation or amine leaching was observed in this study."]},{"key":"dc:title","label":"Title","values":["Steam Regeneration of Amine Impregnated Silica Based Sorbents for Post Combustion CO2 Capture"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gupta, Rajender (Chemical and Materials Engineering)"],"dc:contributor.other":["Hashisho, Zaher (Civil and Environmental Engineering)","Gupta, Rajender (Chemical and Materials Engineering)","Rajendran, Arvind (Chemical and Materials Engineering)"],"dc:creator":["Sandhu, Navjot Kaur"],"dc:date.accessioned":["2025-05-29T08:19:38Z"],"dc:date.available":["2025-05-29T08:19:38Z"],"dc:date.issued":["2014-11"],"dc:description.abstract":["In this study, an experimental investigation of CO2 capture using amine functionalized mesoporous silica based sorbents was carried out. Polyethyleneimine (PEI) impregnated silica sorbents were synthesized and tested in TGA under different adsorption temperatures and partial pressures of CO2. Sorbent characterization was carried out using N2 adsorption-desorption isotherms, FTIR, SEM and elemental analysis. Multiple cycles study was conducted to examine the effect of presence of O2 (0-5%) in flue gas on CO2 adsorption performance of sorbent. A separate packed bed study was conducted to study the effect of different concentrations of moisture (5.27–14.74%) in flue gas on CO2 adsorption and energy requirements for sorbent regeneration. A major study that was undertaken was to test the performance and stability of sorbent under steam stripping conditions. Steam was used for sorbent regeneration in a multiple cycle study and characterization of used sample was carried out to study any change in sorbent properties. Steam at different temperatures was used to study CO2 desorption. Desorption kinetics for steam and inert gas stripping was compared. It was observed that the sorbent performance was stable under steam environment along with improved desorption kinetics over inert gas stripping. No steam condensation or amine leaching was observed in this study."],"dc:identifier.doi":["https://doi.org/10.7939/R37W67C5H"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Post combustion CO2 Capture","Polyethyleneimine","Solid sorbent","Steam regeneration"],"dc:title":["Steam Regeneration of Amine Impregnated Silica Based Sorbents for Post Combustion CO2 Capture"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:02:17Z"}