{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/89951"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/89951","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Parallel Tapping LCC-HVDC Systems with Multiple Modular Multilevel Converters","abstract":"The idea of tapping is to extract a small amount of power from existing high voltage direct current (HVDC) transmission lines to minimize the infrastructure cost in electrifying rural communities. The vast majority of the previous research has focused on tapping schemes utilizing line commutated converter (LCC) based technologies that have operational limitations. With recent advancement of semiconductor devices and the introduction of new converter topologies, in particular, the full-bridge modular multilevel converter (FB-MMC) with direct current (DC) fault blocking capability, HVDC line tapping has regained attention.This thesis presents a detailed hybrid multi-tapping study system developed in PSCAD/EMTDC that comprises two independently controlled FB-MMC-based HVDC tapping stations interfaced to the 1000 MW CIGRÉ LCC-HVDC benchmark model. The feasibility and system performance of the multi-tap stations is verified through extensive simulations that investigate the impact of changes in tapping power flows and varying fault locations at AC side of FB-MMCs. Simulation results reveal the majority of fault scenarios incite undesirable disturbances to the DC current/voltage of the LCC-HVDC system. This thesis develops i) a tap station current modulation method that transiently adjusts the current set-point of the healthy MMC tap, and ii) three supplementary controllers attached to the rectifier/inverter stations to reduce the impact of the tap AC side fault on the main LCC-HVDC system. Both fault mitigating schemes utilize only local measurements and are verified through extensive simulations at various operating points.","abstract_html":"The idea of tapping is to extract a small amount of power from existing high voltage direct current (HVDC) transmission lines to minimize the infrastructure cost in electrifying rural communities. The vast majority of the previous research has focused on tapping schemes utilizing line commutated converter (LCC) based technologies that have operational limitations. With recent advancement of semiconductor devices and the introduction of new converter topologies, in particular, the full-bridge modular multilevel converter (FB-MMC) with direct current (DC) fault blocking capability, HVDC line tapping has regained attention.This thesis presents a detailed hybrid multi-tapping study system developed in PSCAD/EMTDC that comprises two independently controlled FB-MMC-based HVDC tapping stations interfaced to the 1000 MW CIGRÉ LCC-HVDC benchmark model. The feasibility and system performance of the multi-tap stations is verified through extensive simulations that investigate the impact of changes in tapping power flows and varying fault locations at AC side of FB-MMCs. Simulation results reveal the majority of fault scenarios incite undesirable disturbances to the DC current/voltage of the LCC-HVDC system. This thesis develops i) a tap station current modulation method that transiently adjusts the current set-point of the healthy MMC tap, and ii) three supplementary controllers attached to the rectifier/inverter stations to reduce the impact of the tap AC side fault on the main LCC-HVDC system. Both fault mitigating schemes utilize only local measurements and are verified through extensive simulations at various operating points.","abstract_has_math":false,"creators":["Liu, Dalu"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":"Energy Systems","degree_department":null,"school":null,"contributors":[],"advisors":["Kish, Greg J. (Electrical Engineering)","Azad, Sahar P. (Electrical Engineering)"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-06","date_published":"2019-06","updated_at":"2026-11-26T20:56:18Z","subjects":["Modular Multilevel Converter","HVDC","Tapping","Supplementary Control","Line-commutated Converter"],"languages":["en"],"rights":["Permission is hereby granted to the University of Alberta Libraries to reproduce single copies of this thesis and to lend or sell such copies for private, scholarly or scientific research purposes only. Where the thesis is converted to, or otherwise made available in digital form, the University of Alberta will advise potential users of the thesis of these terms. The author reserves all other publication and other rights in association with the copyright in the thesis and, except as herein before provided, neither the thesis nor any substantial portion thereof may be printed or otherwise reproduced in any material form whatsoever without the author's prior written permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/r3-ezsh-br02","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/r3-ezsh-br02","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F89951","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F89951","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kish, Greg J. (Electrical Engineering)","Azad, Sahar P. (Electrical Engineering)"]},{"key":"dc:creator","label":"Author","values":["Liu, Dalu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T08:29:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T08:29:02Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Energy Systems"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Modular Multilevel Converter","HVDC","Tapping","Supplementary Control","Line-commutated Converter"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Permission is hereby granted to the University of Alberta Libraries to reproduce single copies of this thesis and to lend or sell such copies for private, scholarly or scientific research purposes only. Where the thesis is converted to, or otherwise made available in digital form, the University of Alberta will advise potential users of the thesis of these terms. The author reserves all other publication and other rights in association with the copyright in the thesis and, except as herein before provided, neither the thesis nor any substantial portion thereof may be printed or otherwise reproduced in any material form whatsoever without the author's prior written permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/r3-ezsh-br02"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The idea of tapping is to extract a small amount of power from existing high voltage direct current (HVDC) transmission lines to minimize the infrastructure cost in electrifying rural communities. The vast majority of the previous research has focused on tapping schemes utilizing line commutated converter (LCC) based technologies that have operational limitations. With recent advancement of semiconductor devices and the introduction of new converter topologies, in particular, the full-bridge modular multilevel converter (FB-MMC) with direct current (DC) fault blocking capability, HVDC line tapping has regained attention.This thesis presents a detailed hybrid multi-tapping study system developed in PSCAD/EMTDC that comprises two independently controlled FB-MMC-based HVDC tapping stations interfaced to the 1000 MW CIGRÉ LCC-HVDC benchmark model. The feasibility and system performance of the multi-tap stations is verified through extensive simulations that investigate the impact of changes in tapping power flows and varying fault locations at AC side of FB-MMCs. Simulation results reveal the majority of fault scenarios incite undesirable disturbances to the DC current/voltage of the LCC-HVDC system. This thesis develops i) a tap station current modulation method that transiently adjusts the current set-point of the healthy MMC tap, and ii) three supplementary controllers attached to the rectifier/inverter stations to reduce the impact of the tap AC side fault on the main LCC-HVDC system. Both fault mitigating schemes utilize only local measurements and are verified through extensive simulations at various operating points."]},{"key":"dc:title","label":"Title","values":["Parallel Tapping LCC-HVDC Systems with Multiple Modular Multilevel Converters"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kish, Greg J. (Electrical Engineering)","Azad, Sahar P. (Electrical Engineering)"],"dc:creator":["Liu, Dalu"],"dc:date.accessioned":["2025-05-29T08:29:02Z"],"dc:date.available":["2025-05-29T08:29:02Z"],"dc:date.issued":["2019-06"],"dc:description.abstract":["The idea of tapping is to extract a small amount of power from existing high voltage direct current (HVDC) transmission lines to minimize the infrastructure cost in electrifying rural communities. The vast majority of the previous research has focused on tapping schemes utilizing line commutated converter (LCC) based technologies that have operational limitations. With recent advancement of semiconductor devices and the introduction of new converter topologies, in particular, the full-bridge modular multilevel converter (FB-MMC) with direct current (DC) fault blocking capability, HVDC line tapping has regained attention.This thesis presents a detailed hybrid multi-tapping study system developed in PSCAD/EMTDC that comprises two independently controlled FB-MMC-based HVDC tapping stations interfaced to the 1000 MW CIGRÉ LCC-HVDC benchmark model. The feasibility and system performance of the multi-tap stations is verified through extensive simulations that investigate the impact of changes in tapping power flows and varying fault locations at AC side of FB-MMCs. Simulation results reveal the majority of fault scenarios incite undesirable disturbances to the DC current/voltage of the LCC-HVDC system. This thesis develops i) a tap station current modulation method that transiently adjusts the current set-point of the healthy MMC tap, and ii) three supplementary controllers attached to the rectifier/inverter stations to reduce the impact of the tap AC side fault on the main LCC-HVDC system. Both fault mitigating schemes utilize only local measurements and are verified through extensive simulations at various operating points."],"dc:identifier.doi":["https://doi.org/10.7939/r3-ezsh-br02"],"dc:language.iso":["en"],"dc:rights":["Permission is hereby granted to the University of Alberta Libraries to reproduce single copies of this thesis and to lend or sell such copies for private, scholarly or scientific research purposes only. Where the thesis is converted to, or otherwise made available in digital form, the University of Alberta will advise potential users of the thesis of these terms. The author reserves all other publication and other rights in association with the copyright in the thesis and, except as herein before provided, neither the thesis nor any substantial portion thereof may be printed or otherwise reproduced in any material form whatsoever without the author's prior written permission."],"dc:subject":["Modular Multilevel Converter","HVDC","Tapping","Supplementary Control","Line-commutated Converter"],"dc:title":["Parallel Tapping LCC-HVDC Systems with Multiple Modular Multilevel Converters"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Energy Systems"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T20:56:18Z"}