{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/90056"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/90056","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Concrete deep beams reinforced with internal FRP","abstract":"Concrete deep beams with small shear span-to-depth (a/d) ratios are common elements in structures. However, there are few experimental results on the behaviour of FRP reinforced concrete deep beams and no specific modelling techniques exist in design codes for such members. The objectives of this study were to examine the shear behaviour of FRP reinforced concrete deep beams containing no web reinforcement and to develop a modelling technique. Test results of 12 large-scale specimens are reported where the primary variables included the a/d ratio, reinforcement ratio, member height, and concrete strength. The results showed that an arch mechanism was able to form in FRP reinforced concrete beams having a/d ≤ 2.1. A strut and tie modelling procedure adapted from CSA A23.3-04 was capable of accurately predicting the capacity of FRP reinforced concrete deep beams containing no web reinforcement while sectional shear models gave poor, but conservative, predictions.","abstract_html":"Concrete deep beams with small shear span-to-depth (a/d) ratios are common elements in structures. However, there are few experimental results on the behaviour of FRP reinforced concrete deep beams and no specific modelling techniques exist in design codes for such members. The objectives of this study were to examine the shear behaviour of FRP reinforced concrete deep beams containing no web reinforcement and to develop a modelling technique. Test results of 12 large-scale specimens are reported where the primary variables included the a/d ratio, reinforcement ratio, member height, and concrete strength. The results showed that an arch mechanism was able to form in FRP reinforced concrete beams having a/d ≤ 2.1. A strut and tie modelling procedure adapted from CSA A23.3-04 was capable of accurately predicting the capacity of FRP reinforced concrete deep beams containing no web reinforcement while sectional shear models gave poor, but conservative, predictions.","abstract_has_math":false,"creators":["Andermatt, Matthias"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Lubell, Adam (Civil and Environmental Engineering)"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-11","date_published":"2010-11","updated_at":"2026-11-26T21:55:35Z","subjects":["Reinforcement","Deep beam","A/d ratio","Reinforced concrete","Behaviours","Fibre reinforced polymer","FRP","Shear","Shear span-to-depth ratio","Arch","Strut and tie","Experiment"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3TT6V","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3TT6V","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F90056","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F90056","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lubell, Adam (Civil and Environmental Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Grondin, Gilbert (Civil and Environmental Engineering)","Jar, P.-Y. Ben (Mechanical Engineering)"]},{"key":"dc:creator","label":"Author","values":["Andermatt, Matthias"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T08:31:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T08:31:46Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Reinforcement","Deep beam","A/d ratio","Reinforced concrete","Behaviours","Fibre reinforced polymer","FRP","Shear","Shear span-to-depth ratio","Arch","Strut and tie","Experiment"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3TT6V"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Concrete deep beams with small shear span-to-depth (a/d) ratios are common elements in structures. However, there are few experimental results on the behaviour of FRP reinforced concrete deep beams and no specific modelling techniques exist in design codes for such members. The objectives of this study were to examine the shear behaviour of FRP reinforced concrete deep beams containing no web reinforcement and to develop a modelling technique. Test results of 12 large-scale specimens are reported where the primary variables included the a/d ratio, reinforcement ratio, member height, and concrete strength. The results showed that an arch mechanism was able to form in FRP reinforced concrete beams having a/d ≤ 2.1. A strut and tie modelling procedure adapted from CSA A23.3-04 was capable of accurately predicting the capacity of FRP reinforced concrete deep beams containing no web reinforcement while sectional shear models gave poor, but conservative, predictions."]},{"key":"dc:title","label":"Title","values":["Concrete deep beams reinforced with internal FRP"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lubell, Adam (Civil and Environmental Engineering)"],"dc:contributor.other":["Grondin, Gilbert (Civil and Environmental Engineering)","Jar, P.-Y. Ben (Mechanical Engineering)"],"dc:creator":["Andermatt, Matthias"],"dc:date.accessioned":["2025-05-29T08:31:46Z"],"dc:date.available":["2025-05-29T08:31:46Z"],"dc:date.issued":["2010-11"],"dc:description.abstract":["Concrete deep beams with small shear span-to-depth (a/d) ratios are common elements in structures. However, there are few experimental results on the behaviour of FRP reinforced concrete deep beams and no specific modelling techniques exist in design codes for such members. The objectives of this study were to examine the shear behaviour of FRP reinforced concrete deep beams containing no web reinforcement and to develop a modelling technique. Test results of 12 large-scale specimens are reported where the primary variables included the a/d ratio, reinforcement ratio, member height, and concrete strength. The results showed that an arch mechanism was able to form in FRP reinforced concrete beams having a/d ≤ 2.1. A strut and tie modelling procedure adapted from CSA A23.3-04 was capable of accurately predicting the capacity of FRP reinforced concrete deep beams containing no web reinforcement while sectional shear models gave poor, but conservative, predictions."],"dc:identifier.doi":["https://doi.org/10.7939/R3TT6V"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Reinforcement","Deep beam","A/d ratio","Reinforced concrete","Behaviours","Fibre reinforced polymer","FRP","Shear","Shear span-to-depth ratio","Arch","Strut and tie","Experiment"],"dc:title":["Concrete deep beams reinforced with internal FRP"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:55:35Z"}