{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/91273"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/91273","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Polyethylene Oxide Chain Density and Uremic Toxin Effects on Plasma Protein Adsorption","abstract":"Protein adsorption to implanted biomaterials can direct host responses and lead to health complications and device failure. Polyethylene oxide (PEO) is the gold standard film for reducing non-specific protein adsorption. Although polymer chain density is an important factor in determining PEO’s protein-resistant behavior, limited studies have related PEO chain density changes to the adsorption of plasma proteins. Besides, existing literature on protein adsorption primarily offers insights from the use of blood from healthy donors, neglecting changes in the blood that occur in unhealthy patients. In chronic kidney disease (CKD), uremic toxins (UTXs) accumulate in the blood compartment and significantly alter the blood composition. For the advancement of low-fouling surfaces for blood-contacting biomaterials and in the quest for personalized dialysis, addressing this knowledge gap is necessary. To examine this, PEO films with variable chain densities and two different end groups, methoxy (-OCH3) and hydroxy (-OH), were prepared and characterized using dynamic contact angle, ellipsometry, and X-ray photoelectron spectroscopy (XPS), to confirm the successful deposition of PEO. Protein adsorption experiments were conducted using human plasma with and without UTXsto investigate their effect on protein adsorption. It was observed that fibrinogen, albumin, factor XI, complement C3, and IgG were the major proteins detected on both methoxy and hydroxy-PEO-modified films. The addition of UTXs substantially increased protein adsorption to methoxy-terminated PEO films, whereas no specific trend was observed for hydroxy-PEO films. The effect of chain densities did not exhibit a consistent pattern but significantly affected the adsorption of many proteins. This knowledge is integral to developing the standard protein adsorption profile and subsequent advancement of surface technologies that enable personalized treatment strategies for patients with kidney failure.","abstract_html":"Protein adsorption to implanted biomaterials can direct host responses and lead to health complications and device failure. Polyethylene oxide (PEO) is the gold standard film for reducing non-specific protein adsorption. Although polymer chain density is an important factor in determining PEO’s protein-resistant behavior, limited studies have related PEO chain density changes to the adsorption of plasma proteins. Besides, existing literature on protein adsorption primarily offers insights from the use of blood from healthy donors, neglecting changes in the blood that occur in unhealthy patients. In chronic kidney disease (CKD), uremic toxins (UTXs) accumulate in the blood compartment and significantly alter the blood composition. For the advancement of low-fouling surfaces for blood-contacting biomaterials and in the quest for personalized dialysis, addressing this knowledge gap is necessary. To examine this, PEO films with variable chain densities and two different end groups, methoxy (-OCH3) and hydroxy (-OH), were prepared and characterized using dynamic contact angle, ellipsometry, and X-ray photoelectron spectroscopy (XPS), to confirm the successful deposition of PEO. Protein adsorption experiments were conducted using human plasma with and without UTXsto investigate their effect on protein adsorption. It was observed that fibrinogen, albumin, factor XI, complement C3, and IgG were the major proteins detected on both methoxy and hydroxy-PEO-modified films. The addition of UTXs substantially increased protein adsorption to methoxy-terminated PEO films, whereas no specific trend was observed for hydroxy-PEO films. The effect of chain densities did not exhibit a consistent pattern but significantly affected the adsorption of many proteins. This knowledge is integral to developing the standard protein adsorption profile and subsequent advancement of surface technologies that enable personalized treatment strategies for patients with kidney failure.","abstract_has_math":false,"creators":["Pawar, Aishwarya Shrikrishna"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Unsworth, Larry (Chemical and Materials Engineering)"],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-11","date_published":"2024-11","updated_at":"2026-11-26T20:57:33Z","subjects":["Protein adsorption to implanted biomaterials","Polyethylene oxide","Chronic Kidney Disease","Low fouling polymers"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/r3-gk4c-p765","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/r3-gk4c-p765","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F91273","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F91273","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Unsworth, Larry (Chemical and Materials Engineering)"]},{"key":"dc:creator","label":"Author","values":["Pawar, Aishwarya Shrikrishna"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T09:36:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T09:36:38Z"]},{"key":"dc:date.issued","label":"Date","values":["2024-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Protein adsorption to implanted biomaterials","Polyethylene oxide","Chronic Kidney Disease","Low fouling polymers"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/r3-gk4c-p765"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Protein adsorption to implanted biomaterials can direct host responses and lead to health complications and device failure. Polyethylene oxide (PEO) is the gold standard film for reducing non-specific protein adsorption. Although polymer chain density is an important factor in determining PEO’s protein-resistant behavior, limited studies have related PEO chain density changes to the adsorption of plasma proteins. Besides, existing literature on protein adsorption primarily offers insights from the use of blood from healthy donors, neglecting changes in the blood that occur in unhealthy patients. In chronic kidney disease (CKD), uremic toxins (UTXs) accumulate in the blood compartment and significantly alter the blood composition. For the advancement of low-fouling surfaces for blood-contacting biomaterials and in the quest for personalized dialysis, addressing this knowledge gap is necessary. To examine this, PEO films with variable chain densities and two different end groups, methoxy (-OCH3) and hydroxy (-OH), were prepared and characterized using dynamic contact angle, ellipsometry, and X-ray photoelectron spectroscopy (XPS), to confirm the successful deposition of PEO. Protein adsorption experiments were conducted using human plasma with and without UTXsto investigate their effect on protein adsorption. It was observed that fibrinogen, albumin, factor XI, complement C3, and IgG were the major proteins detected on both methoxy and hydroxy-PEO-modified films. The addition of UTXs substantially increased protein adsorption to methoxy-terminated PEO films, whereas no specific trend was observed for hydroxy-PEO films. The effect of chain densities did not exhibit a consistent pattern but significantly affected the adsorption of many proteins. This knowledge is integral to developing the standard protein adsorption profile and subsequent advancement of surface technologies that enable personalized treatment strategies for patients with kidney failure."]},{"key":"dc:title","label":"Title","values":["Polyethylene Oxide Chain Density and Uremic Toxin Effects on Plasma Protein Adsorption"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Unsworth, Larry (Chemical and Materials Engineering)"],"dc:creator":["Pawar, Aishwarya Shrikrishna"],"dc:date.accessioned":["2025-05-29T09:36:38Z"],"dc:date.available":["2025-05-29T09:36:38Z"],"dc:date.issued":["2024-11"],"dc:description.abstract":["Protein adsorption to implanted biomaterials can direct host responses and lead to health complications and device failure. Polyethylene oxide (PEO) is the gold standard film for reducing non-specific protein adsorption. Although polymer chain density is an important factor in determining PEO’s protein-resistant behavior, limited studies have related PEO chain density changes to the adsorption of plasma proteins. Besides, existing literature on protein adsorption primarily offers insights from the use of blood from healthy donors, neglecting changes in the blood that occur in unhealthy patients. In chronic kidney disease (CKD), uremic toxins (UTXs) accumulate in the blood compartment and significantly alter the blood composition. For the advancement of low-fouling surfaces for blood-contacting biomaterials and in the quest for personalized dialysis, addressing this knowledge gap is necessary. To examine this, PEO films with variable chain densities and two different end groups, methoxy (-OCH3) and hydroxy (-OH), were prepared and characterized using dynamic contact angle, ellipsometry, and X-ray photoelectron spectroscopy (XPS), to confirm the successful deposition of PEO. Protein adsorption experiments were conducted using human plasma with and without UTXsto investigate their effect on protein adsorption. It was observed that fibrinogen, albumin, factor XI, complement C3, and IgG were the major proteins detected on both methoxy and hydroxy-PEO-modified films. The addition of UTXs substantially increased protein adsorption to methoxy-terminated PEO films, whereas no specific trend was observed for hydroxy-PEO films. The effect of chain densities did not exhibit a consistent pattern but significantly affected the adsorption of many proteins. This knowledge is integral to developing the standard protein adsorption profile and subsequent advancement of surface technologies that enable personalized treatment strategies for patients with kidney failure."],"dc:identifier.doi":["https://doi.org/10.7939/r3-gk4c-p765"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Protein adsorption to implanted biomaterials","Polyethylene oxide","Chronic Kidney Disease","Low fouling polymers"],"dc:title":["Polyethylene Oxide Chain Density and Uremic Toxin Effects on Plasma Protein Adsorption"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T20:57:33Z"}