{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/92848"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/92848","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Simulation of the Molecular Interactions for the Microcantilever Sensors","abstract":"Microcantilever sensor has gained much popularity because of its high sensitivity and selectivity. It consists of a micro-sized cantilever that is usually coated on one side with chemical/biological probe agents to generate strong attraction to target molecules. The interactions between the probe and target molecules induce surface stress that bends the microcantilever. This current work applied the molecular dynamics simulation to study the microcantilever system. Lennard-Jones potentials were used to model the target-target and target-probe interactions and bond bending potentials to model the solid cantilever beam. In addition, this work studied the effect of probe locations on the microcantilever deflection. The simulation results suggest that both target-target and target-probe interactions as well as the probe locations affect the arrangement of the bonds; in term of the bonding number, the area containing the bonded molecules, and the distances between them. All these factors influence the microcantilever deflection.","abstract_html":"Microcantilever sensor has gained much popularity because of its high sensitivity and selectivity. It consists of a micro-sized cantilever that is usually coated on one side with chemical/biological probe agents to generate strong attraction to target molecules. The interactions between the probe and target molecules induce surface stress that bends the microcantilever. This current work applied the molecular dynamics simulation to study the microcantilever system. Lennard-Jones potentials were used to model the target-target and target-probe interactions and bond bending potentials to model the solid cantilever beam. In addition, this work studied the effect of probe locations on the microcantilever deflection. The simulation results suggest that both target-target and target-probe interactions as well as the probe locations affect the arrangement of the bonds; in term of the bonding number, the area containing the bonded molecules, and the distances between them. All these factors influence the microcantilever deflection.","abstract_has_math":false,"creators":["Khosathit, Padet"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Jar, P.-Y. Ben (Mechanical Engineering)","Choi, Phillip Y. K. (Chemical and Materials Engineering)"],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-11","date_published":"2009-11","updated_at":"2026-11-26T21:56:06Z","subjects":["Bond Bending Potential","Biosensors","Lattice Spring","Molecular dynamics simulations","Atomic Force Microscopy","Microcantilever Sensor","Molecular Interactions","Nanocantilever","Lennard-Jones Potential","Chemical Detection"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3436D","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3436D","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F92848","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F92848","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jar, P.-Y. Ben (Mechanical Engineering)","Choi, Phillip Y. K. (Chemical and Materials Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["McDonald, Andre G.","Choi, Phillip Y. K. (Chemical and Materials Engineering)","Jar, P.-Y. Ben (Mechanical Engineering)"]},{"key":"dc:creator","label":"Author","values":["Khosathit, Padet"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T10:52:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T10:52:30Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bond Bending Potential","Biosensors","Lattice Spring","Molecular dynamics simulations","Atomic Force Microscopy","Microcantilever Sensor","Molecular Interactions","Nanocantilever","Lennard-Jones Potential","Chemical Detection"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3436D"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Microcantilever sensor has gained much popularity because of its high sensitivity and selectivity. It consists of a micro-sized cantilever that is usually coated on one side with chemical/biological probe agents to generate strong attraction to target molecules. The interactions between the probe and target molecules induce surface stress that bends the microcantilever. This current work applied the molecular dynamics simulation to study the microcantilever system. Lennard-Jones potentials were used to model the target-target and target-probe interactions and bond bending potentials to model the solid cantilever beam. In addition, this work studied the effect of probe locations on the microcantilever deflection. The simulation results suggest that both target-target and target-probe interactions as well as the probe locations affect the arrangement of the bonds; in term of the bonding number, the area containing the bonded molecules, and the distances between them. All these factors influence the microcantilever deflection."]},{"key":"dc:title","label":"Title","values":["Simulation of the Molecular Interactions for the Microcantilever Sensors"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jar, P.-Y. Ben (Mechanical Engineering)","Choi, Phillip Y. K. (Chemical and Materials Engineering)"],"dc:contributor.other":["McDonald, Andre G.","Choi, Phillip Y. K. (Chemical and Materials Engineering)","Jar, P.-Y. Ben (Mechanical Engineering)"],"dc:creator":["Khosathit, Padet"],"dc:date.accessioned":["2025-05-29T10:52:30Z"],"dc:date.available":["2025-05-29T10:52:30Z"],"dc:date.issued":["2009-11"],"dc:description.abstract":["Microcantilever sensor has gained much popularity because of its high sensitivity and selectivity. It consists of a micro-sized cantilever that is usually coated on one side with chemical/biological probe agents to generate strong attraction to target molecules. The interactions between the probe and target molecules induce surface stress that bends the microcantilever. This current work applied the molecular dynamics simulation to study the microcantilever system. Lennard-Jones potentials were used to model the target-target and target-probe interactions and bond bending potentials to model the solid cantilever beam. In addition, this work studied the effect of probe locations on the microcantilever deflection. The simulation results suggest that both target-target and target-probe interactions as well as the probe locations affect the arrangement of the bonds; in term of the bonding number, the area containing the bonded molecules, and the distances between them. All these factors influence the microcantilever deflection."],"dc:identifier.doi":["https://doi.org/10.7939/R3436D"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Bond Bending Potential","Biosensors","Lattice Spring","Molecular dynamics simulations","Atomic Force Microscopy","Microcantilever Sensor","Molecular Interactions","Nanocantilever","Lennard-Jones Potential","Chemical Detection"],"dc:title":["Simulation of the Molecular Interactions for the Microcantilever Sensors"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:56:06Z"}