{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/92869"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/92869","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Study of the Response of PICASSO Bubble Detectors to Neutron Irradiation","abstract":"The objective of this work was to simulate the PICASSO experiment and to study the detector response to neutron irradiation. The results of the sim- ulation show the rock neutron rate to be 1-2 neutrons/day for the setup used until 2009 and less than 0.1 neutrons/day for the setup used after 2010. The shielding efficiency was calculated to be 98% and 99.6% for the two setups re- spectively. The detector response to an AmBe source was simulated. Neutron rates differ for two AmBe source spectra from the literature. The observed data rate is in agreement with the rate from the simulation. The detector stability was examined and found to be stable. The source position and orien- tation affect the detector efficiency creating a systematic uncertainity on the order of 10-35%. This uncertainity was eliminated with a source holder.","abstract_html":"The objective of this work was to simulate the PICASSO experiment and to study the detector response to neutron irradiation. The results of the sim- ulation show the rock neutron rate to be 1-2 neutrons/day for the setup used until 2009 and less than 0.1 neutrons/day for the setup used after 2010. The shielding efficiency was calculated to be 98% and 99.6% for the two setups re- spectively. The detector response to an AmBe source was simulated. Neutron rates differ for two AmBe source spectra from the literature. The observed data rate is in agreement with the rate from the simulation. The detector stability was examined and found to be stable. The source position and orien- tation affect the detector efficiency creating a systematic uncertainity on the order of 10-35%. This uncertainity was eliminated with a source holder.","abstract_has_math":false,"creators":["Marlisov, Daniiar"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Krauss, Carsten (Department of Physics)"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-06","date_published":"2013-06","updated_at":"2026-11-26T20:50:30Z","subjects":["PICASSO"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R31H1Q","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R31H1Q","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F92869","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F92869","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Krauss, Carsten (Department of Physics)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Penin, Alexander (Department of Physics)","Duke, John (SLOWPOKE)","Marchand, Richard (Department of Physics)"]},{"key":"dc:creator","label":"Author","values":["Marlisov, Daniiar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T10:52:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T10:52:34Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["PICASSO"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R31H1Q"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this work was to simulate the PICASSO experiment and to study the detector response to neutron irradiation. The results of the sim- ulation show the rock neutron rate to be 1-2 neutrons/day for the setup used until 2009 and less than 0.1 neutrons/day for the setup used after 2010. The shielding efficiency was calculated to be 98% and 99.6% for the two setups re- spectively. The detector response to an AmBe source was simulated. Neutron rates differ for two AmBe source spectra from the literature. The observed data rate is in agreement with the rate from the simulation. The detector stability was examined and found to be stable. The source position and orien- tation affect the detector efficiency creating a systematic uncertainity on the order of 10-35%. This uncertainity was eliminated with a source holder."]},{"key":"dc:title","label":"Title","values":["Study of the Response of PICASSO Bubble Detectors to Neutron Irradiation"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["PICASSO experiment"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Krauss, Carsten (Department of Physics)"],"dc:contributor.other":["Penin, Alexander (Department of Physics)","Duke, John (SLOWPOKE)","Marchand, Richard (Department of Physics)"],"dc:creator":["Marlisov, Daniiar"],"dc:date.accessioned":["2025-05-29T10:52:34Z"],"dc:date.available":["2025-05-29T10:52:34Z"],"dc:date.issued":["2013-06"],"dc:description.abstract":["The objective of this work was to simulate the PICASSO experiment and to study the detector response to neutron irradiation. The results of the sim- ulation show the rock neutron rate to be 1-2 neutrons/day for the setup used until 2009 and less than 0.1 neutrons/day for the setup used after 2010. The shielding efficiency was calculated to be 98% and 99.6% for the two setups re- spectively. The detector response to an AmBe source was simulated. Neutron rates differ for two AmBe source spectra from the literature. The observed data rate is in agreement with the rate from the simulation. The detector stability was examined and found to be stable. The source position and orien- tation affect the detector efficiency creating a systematic uncertainity on the order of 10-35%. This uncertainity was eliminated with a source holder."],"dc:identifier.doi":["https://doi.org/10.7939/R31H1Q"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["PICASSO"],"dc:title":["Study of the Response of PICASSO Bubble Detectors to Neutron Irradiation"],"dc:title.alternative":["PICASSO experiment"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T20:50:30Z"}