{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/93026"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/93026","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"UV Aging of Polyurethane Films and its Application for A Graphene-Based End-of-Life Sensor","abstract":"To improve the safety of workers in high-risk industries like firefighting, our research group at the University of Alberta has collaborated with industry partners to develop an end-of-life sensor. This sensor consists of three individual sensors - a heat sensor, a UV sensor, and a moisture sensor - designed to simulate the effects of specific conditions on the outer shell fabric of firefighter's protective garments. It includes a sacrificial polymer layer that degrades over time, in contact with a graphene conductive track. By monitoring the decrease in conductivity of the graphene track as the sacrificial layer degrades, we can predict the eventual loss of protective properties of the fabric, without destroying it. This non-destructive method can ensure the performance of protective clothing, and ultimately improve worker safety. In this thesis, the sacrificial polymer for the UV-sensitive part of a graphene-based end-of-life sensor for fire-protective fabrics is investigated. A commercial 2-pack polyurethane (2-PUR) emerged as a favorable candidate, demonstrating a high degree of sensitivity to UV radiation, flexibility, durability. It can also be cast into a film form, and it is water-resistant. Moreover, it passed the NFPA 1971 heat resistance requirement for fire-fighting ensemble components. UV exposure on the 2-PUR makes the material increasingly brittle over time, leading to an eventual fractured. Notably, the kinetics of UV degradation of the 2-PUR was compared to that of a fabric used as an outer shell of fire-protective clothing. In addition, the activation energy, corresponding to the effect of temperature on the UV aging was computed using the combination of time-temperature-superposition principle and Arrhenius plot. When UV stabilizers were added to the 2-PUR, the degradation of the film was delayed, enabling us to tune the end-of-life sensor response to the degradation kinetics of various fire-protective fabrics used in firefighters’ protective clothing. This study's results can provide practical guidelines for the use of a 2-PUR system as a sacrificial polymer layer to simulate the UV degradation of fire-resistant fabric in end-of-life UV sensors. The creation of the graphene-based end-of-life sensor for fire-protective fabrics represents a significant milestone for the protective clothing industry as a novel non-destructive method of assessing the fabric’s degradation, particularly for firefighters' safety.","abstract_html":"To improve the safety of workers in high-risk industries like firefighting, our research group at the University of Alberta has collaborated with industry partners to develop an end-of-life sensor. This sensor consists of three individual sensors - a heat sensor, a UV sensor, and a moisture sensor - designed to simulate the effects of specific conditions on the outer shell fabric of firefighter&#x27;s protective garments. It includes a sacrificial polymer layer that degrades over time, in contact with a graphene conductive track. By monitoring the decrease in conductivity of the graphene track as the sacrificial layer degrades, we can predict the eventual loss of protective properties of the fabric, without destroying it. This non-destructive method can ensure the performance of protective clothing, and ultimately improve worker safety. In this thesis, the sacrificial polymer for the UV-sensitive part of a graphene-based end-of-life sensor for fire-protective fabrics is investigated. A commercial 2-pack polyurethane (2-PUR) emerged as a favorable candidate, demonstrating a high degree of sensitivity to UV radiation, flexibility, durability. It can also be cast into a film form, and it is water-resistant. Moreover, it passed the NFPA 1971 heat resistance requirement for fire-fighting ensemble components. UV exposure on the 2-PUR makes the material increasingly brittle over time, leading to an eventual fractured. Notably, the kinetics of UV degradation of the 2-PUR was compared to that of a fabric used as an outer shell of fire-protective clothing. In addition, the activation energy, corresponding to the effect of temperature on the UV aging was computed using the combination of time-temperature-superposition principle and Arrhenius plot. When UV stabilizers were added to the 2-PUR, the degradation of the film was delayed, enabling us to tune the end-of-life sensor response to the degradation kinetics of various fire-protective fabrics used in firefighters’ protective clothing. This study&#x27;s results can provide practical guidelines for the use of a 2-PUR system as a sacrificial polymer layer to simulate the UV degradation of fire-resistant fabric in end-of-life UV sensors. The creation of the graphene-based end-of-life sensor for fire-protective fabrics represents a significant milestone for the protective clothing industry as a novel non-destructive method of assessing the fabric’s degradation, particularly for firefighters&#x27; safety.","abstract_has_math":false,"creators":["Khemir, Marwa"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":"Materials Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Hyun Joong Chung - Chemical and Materials Engineering Department","Patricia Dolez - Human Ecology Department"],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-11","date_published":"2023-11","updated_at":"2026-11-26T21:59:47Z","subjects":["UV aging of polyurethane"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/r3-wkz5-ak62","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/r3-wkz5-ak62","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F93026","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F93026","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hyun Joong Chung - Chemical and Materials Engineering Department","Patricia Dolez - Human Ecology Department"]},{"key":"dc:creator","label":"Author","values":["Khemir, Marwa"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T10:53:40Z"]},{"key":"dc:date.issued","label":"Date","values":["2023-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["UV aging of polyurethane"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/r3-wkz5-ak62"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["To improve the safety of workers in high-risk industries like firefighting, our research group at the University of Alberta has collaborated with industry partners to develop an end-of-life sensor. This sensor consists of three individual sensors - a heat sensor, a UV sensor, and a moisture sensor - designed to simulate the effects of specific conditions on the outer shell fabric of firefighter's protective garments. It includes a sacrificial polymer layer that degrades over time, in contact with a graphene conductive track. By monitoring the decrease in conductivity of the graphene track as the sacrificial layer degrades, we can predict the eventual loss of protective properties of the fabric, without destroying it. This non-destructive method can ensure the performance of protective clothing, and ultimately improve worker safety. In this thesis, the sacrificial polymer for the UV-sensitive part of a graphene-based end-of-life sensor for fire-protective fabrics is investigated. A commercial 2-pack polyurethane (2-PUR) emerged as a favorable candidate, demonstrating a high degree of sensitivity to UV radiation, flexibility, durability. It can also be cast into a film form, and it is water-resistant. Moreover, it passed the NFPA 1971 heat resistance requirement for fire-fighting ensemble components. UV exposure on the 2-PUR makes the material increasingly brittle over time, leading to an eventual fractured. Notably, the kinetics of UV degradation of the 2-PUR was compared to that of a fabric used as an outer shell of fire-protective clothing. In addition, the activation energy, corresponding to the effect of temperature on the UV aging was computed using the combination of time-temperature-superposition principle and Arrhenius plot. When UV stabilizers were added to the 2-PUR, the degradation of the film was delayed, enabling us to tune the end-of-life sensor response to the degradation kinetics of various fire-protective fabrics used in firefighters’ protective clothing. This study's results can provide practical guidelines for the use of a 2-PUR system as a sacrificial polymer layer to simulate the UV degradation of fire-resistant fabric in end-of-life UV sensors. The creation of the graphene-based end-of-life sensor for fire-protective fabrics represents a significant milestone for the protective clothing industry as a novel non-destructive method of assessing the fabric’s degradation, particularly for firefighters' safety."]},{"key":"dc:title","label":"Title","values":["UV Aging of Polyurethane Films and its Application for A Graphene-Based End-of-Life Sensor"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hyun Joong Chung - Chemical and Materials Engineering Department","Patricia Dolez - Human Ecology Department"],"dc:creator":["Khemir, Marwa"],"dc:date.accessioned":["2025-05-29T10:53:40Z"],"dc:date.issued":["2023-11"],"dc:description.abstract":["To improve the safety of workers in high-risk industries like firefighting, our research group at the University of Alberta has collaborated with industry partners to develop an end-of-life sensor. This sensor consists of three individual sensors - a heat sensor, a UV sensor, and a moisture sensor - designed to simulate the effects of specific conditions on the outer shell fabric of firefighter's protective garments. It includes a sacrificial polymer layer that degrades over time, in contact with a graphene conductive track. By monitoring the decrease in conductivity of the graphene track as the sacrificial layer degrades, we can predict the eventual loss of protective properties of the fabric, without destroying it. This non-destructive method can ensure the performance of protective clothing, and ultimately improve worker safety. In this thesis, the sacrificial polymer for the UV-sensitive part of a graphene-based end-of-life sensor for fire-protective fabrics is investigated. A commercial 2-pack polyurethane (2-PUR) emerged as a favorable candidate, demonstrating a high degree of sensitivity to UV radiation, flexibility, durability. It can also be cast into a film form, and it is water-resistant. Moreover, it passed the NFPA 1971 heat resistance requirement for fire-fighting ensemble components. UV exposure on the 2-PUR makes the material increasingly brittle over time, leading to an eventual fractured. Notably, the kinetics of UV degradation of the 2-PUR was compared to that of a fabric used as an outer shell of fire-protective clothing. In addition, the activation energy, corresponding to the effect of temperature on the UV aging was computed using the combination of time-temperature-superposition principle and Arrhenius plot. When UV stabilizers were added to the 2-PUR, the degradation of the film was delayed, enabling us to tune the end-of-life sensor response to the degradation kinetics of various fire-protective fabrics used in firefighters’ protective clothing. This study's results can provide practical guidelines for the use of a 2-PUR system as a sacrificial polymer layer to simulate the UV degradation of fire-resistant fabric in end-of-life UV sensors. The creation of the graphene-based end-of-life sensor for fire-protective fabrics represents a significant milestone for the protective clothing industry as a novel non-destructive method of assessing the fabric’s degradation, particularly for firefighters' safety."],"dc:identifier.doi":["https://doi.org/10.7939/r3-wkz5-ak62"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["UV aging of polyurethane"],"dc:title":["UV Aging of Polyurethane Films and its Application for A Graphene-Based End-of-Life Sensor"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Materials Engineering"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:59:47Z"}