{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/94074"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/94074","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Cryogenic Optomechanics with Silica Microresonators","abstract":"Cavity optomechanical devices are interesting systems for probing quantum mechanical behaviour of mesoscopic objects. A basic requirement for these types of experiments is preparation of the mechanical resonator in, or at least very close to, its ground state. Although active laser cooling techniques can help this process, conventional cryogenic (pre-)cooling is nonetheless necessary. This thesis introduces a custom-made apparatus, housed on the base plate of a commercial dilution refrigerator, for coupling light into an optomechanical resonator via a tapered optical fiber. Our system incorporates full three-dimensional control of the taper-resonator coupling conditions, enabling critical coupling at cryogenic temperatures. It also features an optical microscope which permits in situ imaging and alignment of the taper and resonator, while causing minimal heating to the environment. Optomechanical measurements of silica bottle resonators, which exhibit optical whispering gallery modes and high-quality mechanical breathing modes, are performed using the dilution fridge system. Several methods for enhancing the detection of small mechanical signals are tested and a method for determining the temperature of the mechanical mode is described and implemented. The tight confinement of light circulating in the bottle resonator leads to increased optical absorption and significant heating of the silica, which manifests itself in both the optical and mechanical properties of the resonator. We present the first measurements of these resonators for mechanical mode temperatures as low as 4 K, and fridge temperatures down to 9 mK.","abstract_html":"Cavity optomechanical devices are interesting systems for probing quantum mechanical behaviour of mesoscopic objects. A basic requirement for these types of experiments is preparation of the mechanical resonator in, or at least very close to, its ground state. Although active laser cooling techniques can help this process, conventional cryogenic (pre-)cooling is nonetheless necessary. This thesis introduces a custom-made apparatus, housed on the base plate of a commercial dilution refrigerator, for coupling light into an optomechanical resonator via a tapered optical fiber. Our system incorporates full three-dimensional control of the taper-resonator coupling conditions, enabling critical coupling at cryogenic temperatures. It also features an optical microscope which permits in situ imaging and alignment of the taper and resonator, while causing minimal heating to the environment. Optomechanical measurements of silica bottle resonators, which exhibit optical whispering gallery modes and high-quality mechanical breathing modes, are performed using the dilution fridge system. Several methods for enhancing the detection of small mechanical signals are tested and a method for determining the temperature of the mechanical mode is described and implemented. The tight confinement of light circulating in the bottle resonator leads to increased optical absorption and significant heating of the silica, which manifests itself in both the optical and mechanical properties of the resonator. We present the first measurements of these resonators for mechanical mode temperatures as low as 4 K, and fridge temperatures down to 9 mK.","abstract_has_math":false,"creators":["MacDonald, Allison J. R."],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Davis, John (Physics)"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-11","date_published":"2015-11","updated_at":"2026-11-26T21:05:53Z","subjects":["Dilution refrigeration","Optomechanics","Tapered fiber","Low temperature imaging","Optical resonators","Mechanical mode thermometry"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R36W96H85","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R36W96H85","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F94074","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F94074","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Davis, John (Physics)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["LeBlanc, Lindsay (Physics)","Hegmann, Frank (Physics)","Freeman, Mark (Physics)","Davis, John (Physics)"]},{"key":"dc:creator","label":"Author","values":["MacDonald, Allison J. R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T11:10:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T11:10:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dilution refrigeration","Optomechanics","Tapered fiber","Low temperature imaging","Optical resonators","Mechanical mode thermometry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R36W96H85"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cavity optomechanical devices are interesting systems for probing quantum mechanical behaviour of mesoscopic objects. A basic requirement for these types of experiments is preparation of the mechanical resonator in, or at least very close to, its ground state. Although active laser cooling techniques can help this process, conventional cryogenic (pre-)cooling is nonetheless necessary. This thesis introduces a custom-made apparatus, housed on the base plate of a commercial dilution refrigerator, for coupling light into an optomechanical resonator via a tapered optical fiber. Our system incorporates full three-dimensional control of the taper-resonator coupling conditions, enabling critical coupling at cryogenic temperatures. It also features an optical microscope which permits in situ imaging and alignment of the taper and resonator, while causing minimal heating to the environment. Optomechanical measurements of silica bottle resonators, which exhibit optical whispering gallery modes and high-quality mechanical breathing modes, are performed using the dilution fridge system. Several methods for enhancing the detection of small mechanical signals are tested and a method for determining the temperature of the mechanical mode is described and implemented. The tight confinement of light circulating in the bottle resonator leads to increased optical absorption and significant heating of the silica, which manifests itself in both the optical and mechanical properties of the resonator. We present the first measurements of these resonators for mechanical mode temperatures as low as 4 K, and fridge temperatures down to 9 mK."]},{"key":"dc:title","label":"Title","values":["Cryogenic Optomechanics with Silica Microresonators"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Davis, John (Physics)"],"dc:contributor.other":["LeBlanc, Lindsay (Physics)","Hegmann, Frank (Physics)","Freeman, Mark (Physics)","Davis, John (Physics)"],"dc:creator":["MacDonald, Allison J. R."],"dc:date.accessioned":["2025-05-29T11:10:13Z"],"dc:date.available":["2025-05-29T11:10:13Z"],"dc:date.issued":["2015-11"],"dc:description.abstract":["Cavity optomechanical devices are interesting systems for probing quantum mechanical behaviour of mesoscopic objects. A basic requirement for these types of experiments is preparation of the mechanical resonator in, or at least very close to, its ground state. Although active laser cooling techniques can help this process, conventional cryogenic (pre-)cooling is nonetheless necessary. This thesis introduces a custom-made apparatus, housed on the base plate of a commercial dilution refrigerator, for coupling light into an optomechanical resonator via a tapered optical fiber. Our system incorporates full three-dimensional control of the taper-resonator coupling conditions, enabling critical coupling at cryogenic temperatures. It also features an optical microscope which permits in situ imaging and alignment of the taper and resonator, while causing minimal heating to the environment. Optomechanical measurements of silica bottle resonators, which exhibit optical whispering gallery modes and high-quality mechanical breathing modes, are performed using the dilution fridge system. Several methods for enhancing the detection of small mechanical signals are tested and a method for determining the temperature of the mechanical mode is described and implemented. The tight confinement of light circulating in the bottle resonator leads to increased optical absorption and significant heating of the silica, which manifests itself in both the optical and mechanical properties of the resonator. We present the first measurements of these resonators for mechanical mode temperatures as low as 4 K, and fridge temperatures down to 9 mK."],"dc:identifier.doi":["https://doi.org/10.7939/R36W96H85"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Dilution refrigeration","Optomechanics","Tapered fiber","Low temperature imaging","Optical resonators","Mechanical mode thermometry"],"dc:title":["Cryogenic Optomechanics with Silica Microresonators"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:05:53Z"}