{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/96822"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/96822","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"An Investigation of Power Quality Issues Associated With Shunt Capacitor Applications","abstract":"Shunt capacitors are widely used in power systems for voltage support and reactive power compensation. Its applications, however, can also cause various problems. This thesis presents a comprehensive investigation of the power quality issues associated with shunt capacitor applications. Switching of shunt capacitors can cause severe transient overvoltage. This thesis first develops a frequency-domain method to simulate the transients. Then, the relationship between three-phase capacitor switching instants and transient voltage peak is analytically studied. The worst-case switching transient is determined accordingly through a systematic searching from a series of transient simulations. Finally, a transfer impedance ranking technique is proposed to effectively identify the most critical buses in capacitor switching. Additionally, shunt capacitors excite resonant conditions that can magnify harmonic levels. One detrimental consequence could be the overloading of capacitors. This thesis establishes a suite of indices that can effectively quantify capacitor loading condition and the impact of harmonics on capacitor loading.","abstract_html":"Shunt capacitors are widely used in power systems for voltage support and reactive power compensation. Its applications, however, can also cause various problems. This thesis presents a comprehensive investigation of the power quality issues associated with shunt capacitor applications. Switching of shunt capacitors can cause severe transient overvoltage. This thesis first develops a frequency-domain method to simulate the transients. Then, the relationship between three-phase capacitor switching instants and transient voltage peak is analytically studied. The worst-case switching transient is determined accordingly through a systematic searching from a series of transient simulations. Finally, a transfer impedance ranking technique is proposed to effectively identify the most critical buses in capacitor switching. Additionally, shunt capacitors excite resonant conditions that can magnify harmonic levels. One detrimental consequence could be the overloading of capacitors. This thesis establishes a suite of indices that can effectively quantify capacitor loading condition and the impact of harmonics on capacitor loading.","abstract_has_math":false,"creators":["Tian, Yu"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":"Energy Systems","degree_department":null,"school":null,"contributors":[],"advisors":["Xu, Wilsun (Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-11","date_published":"2014-11","updated_at":"2026-11-26T20:54:44Z","subjects":["Capacitor","Switching Transients","Power systems"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3WX07","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3WX07","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F96822","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F96822","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Xu, Wilsun (Electrical and Computer Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Xu, Wilsun (Electrical and Computer Engineering)","Dinavahi, Venkata (Electrical and Computer Engineering)","Li, Yunwei (Electrical and Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Tian, Yu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T13:26:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T13:26:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Energy Systems"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Capacitor","Switching Transients","Power systems"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3WX07"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Shunt capacitors are widely used in power systems for voltage support and reactive power compensation. Its applications, however, can also cause various problems. This thesis presents a comprehensive investigation of the power quality issues associated with shunt capacitor applications. Switching of shunt capacitors can cause severe transient overvoltage. This thesis first develops a frequency-domain method to simulate the transients. Then, the relationship between three-phase capacitor switching instants and transient voltage peak is analytically studied. The worst-case switching transient is determined accordingly through a systematic searching from a series of transient simulations. Finally, a transfer impedance ranking technique is proposed to effectively identify the most critical buses in capacitor switching. Additionally, shunt capacitors excite resonant conditions that can magnify harmonic levels. One detrimental consequence could be the overloading of capacitors. This thesis establishes a suite of indices that can effectively quantify capacitor loading condition and the impact of harmonics on capacitor loading."]},{"key":"dc:title","label":"Title","values":["An Investigation of Power Quality Issues Associated With Shunt Capacitor Applications"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Xu, Wilsun (Electrical and Computer Engineering)"],"dc:contributor.other":["Xu, Wilsun (Electrical and Computer Engineering)","Dinavahi, Venkata (Electrical and Computer Engineering)","Li, Yunwei (Electrical and Computer Engineering)"],"dc:creator":["Tian, Yu"],"dc:date.accessioned":["2025-05-29T13:26:49Z"],"dc:date.available":["2025-05-29T13:26:49Z"],"dc:date.issued":["2014-11"],"dc:description.abstract":["Shunt capacitors are widely used in power systems for voltage support and reactive power compensation. Its applications, however, can also cause various problems. This thesis presents a comprehensive investigation of the power quality issues associated with shunt capacitor applications. Switching of shunt capacitors can cause severe transient overvoltage. This thesis first develops a frequency-domain method to simulate the transients. Then, the relationship between three-phase capacitor switching instants and transient voltage peak is analytically studied. The worst-case switching transient is determined accordingly through a systematic searching from a series of transient simulations. Finally, a transfer impedance ranking technique is proposed to effectively identify the most critical buses in capacitor switching. Additionally, shunt capacitors excite resonant conditions that can magnify harmonic levels. One detrimental consequence could be the overloading of capacitors. This thesis establishes a suite of indices that can effectively quantify capacitor loading condition and the impact of harmonics on capacitor loading."],"dc:identifier.doi":["https://doi.org/10.7939/R3WX07"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Capacitor","Switching Transients","Power systems"],"dc:title":["An Investigation of Power Quality Issues Associated With Shunt Capacitor Applications"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Energy Systems"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T20:54:44Z"}