{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/97160"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/97160","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Morphology control and localized surface plasmon resonance in glancing angle deposited films","abstract":"This research investigates an extension of the glancing angle deposition (GLAD) technique and a biosensing application of films produced by GLAD. The extension to GLAD, called phi-sweep (PS), improves column isolation compared to films grown by traditional GLAD (TG) as well as modifies the column tilt angle, β, of the slanted columns according to tan(β_{PS}) = tan(β_{TG}) cos(γ), where γ is the sweep angle. The biosensing application makes use of localized surface plasmon resonance in noble metal GLAD films functionalized with rabbit immunoglobulin G (rIgG) to detect binding of anti-rabbit immunoglobulin G (anti-rIgG) to the films' surface. The extinction peak red-shifts a distance dependent on the concentration of anti-rIgG solution in a manner described by the Langmuir isotherm with a saturation value, Δλ_{max}, of 29.4 ± 0.7 nm and a surface confined thermodynamic binding constant, Kₐ, of (2.7 ± 0.3)×10⁶ M⁻¹.","abstract_html":"This research investigates an extension of the glancing angle deposition (GLAD) technique and a biosensing application of films produced by GLAD. The extension to GLAD, called phi-sweep (PS), improves column isolation compared to films grown by traditional GLAD (TG) as well as modifies the column tilt angle, β, of the slanted columns according to tan(β_{PS}) = tan(β_{TG}) cos(γ), where γ is the sweep angle. The biosensing application makes use of localized surface plasmon resonance in noble metal GLAD films functionalized with rabbit immunoglobulin G (rIgG) to detect binding of anti-rabbit immunoglobulin G (anti-rIgG) to the films&#x27; surface. The extinction peak red-shifts a distance dependent on the concentration of anti-rIgG solution in a manner described by the Langmuir isotherm with a saturation value, Δλ_{max}, of 29.4 ± 0.7 nm and a surface confined thermodynamic binding constant, Kₐ, of (2.7 ± 0.3)×10⁶ M⁻¹.","abstract_has_math":false,"creators":["Gish, Douglas"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Brett, Michael (Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-11","date_published":"2010-11","updated_at":"2026-11-26T21:59:11Z","subjects":["Thin films","Phi-sweep","Biosensing","Glancing angle deposition","Localized surface plasmon resonance"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R39W2C","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R39W2C","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F97160","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F97160","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brett, Michael (Electrical and Computer Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Brett, Michael (Electrical and Computer Engineering)","McDermott, Mark (Chemistry)","Sit, Jeremy (Electrical and Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Gish, Douglas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T13:29:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T13:29:14Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Thin films","Phi-sweep","Biosensing","Glancing angle deposition","Localized surface plasmon resonance"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R39W2C"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This research investigates an extension of the glancing angle deposition (GLAD) technique and a biosensing application of films produced by GLAD. The extension to GLAD, called phi-sweep (PS), improves column isolation compared to films grown by traditional GLAD (TG) as well as modifies the column tilt angle, β, of the slanted columns according to tan(β_{PS}) = tan(β_{TG}) cos(γ), where γ is the sweep angle. The biosensing application makes use of localized surface plasmon resonance in noble metal GLAD films functionalized with rabbit immunoglobulin G (rIgG) to detect binding of anti-rabbit immunoglobulin G (anti-rIgG) to the films' surface. The extinction peak red-shifts a distance dependent on the concentration of anti-rIgG solution in a manner described by the Langmuir isotherm with a saturation value, Δλ_{max}, of 29.4 ± 0.7 nm and a surface confined thermodynamic binding constant, Kₐ, of (2.7 ± 0.3)×10⁶ M⁻¹."]},{"key":"dc:title","label":"Title","values":["Morphology control and localized surface plasmon resonance in glancing angle deposited films"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brett, Michael (Electrical and Computer Engineering)"],"dc:contributor.other":["Brett, Michael (Electrical and Computer Engineering)","McDermott, Mark (Chemistry)","Sit, Jeremy (Electrical and Computer Engineering)"],"dc:creator":["Gish, Douglas"],"dc:date.accessioned":["2025-05-29T13:29:14Z"],"dc:date.available":["2025-05-29T13:29:14Z"],"dc:date.issued":["2010-11"],"dc:description.abstract":["This research investigates an extension of the glancing angle deposition (GLAD) technique and a biosensing application of films produced by GLAD. The extension to GLAD, called phi-sweep (PS), improves column isolation compared to films grown by traditional GLAD (TG) as well as modifies the column tilt angle, β, of the slanted columns according to tan(β_{PS}) = tan(β_{TG}) cos(γ), where γ is the sweep angle. The biosensing application makes use of localized surface plasmon resonance in noble metal GLAD films functionalized with rabbit immunoglobulin G (rIgG) to detect binding of anti-rabbit immunoglobulin G (anti-rIgG) to the films' surface. The extinction peak red-shifts a distance dependent on the concentration of anti-rIgG solution in a manner described by the Langmuir isotherm with a saturation value, Δλ_{max}, of 29.4 ± 0.7 nm and a surface confined thermodynamic binding constant, Kₐ, of (2.7 ± 0.3)×10⁶ M⁻¹."],"dc:identifier.doi":["https://doi.org/10.7939/R39W2C"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Thin films","Phi-sweep","Biosensing","Glancing angle deposition","Localized surface plasmon resonance"],"dc:title":["Morphology control and localized surface plasmon resonance in glancing angle deposited films"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:59:11Z"}