{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/97397"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/97397","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"AC Frequency-based Cyclical Electrical Stimulation of Hydrogel Microactuators","abstract":"The continuing interest in Lab-on-a-Chip technologies and Point-of-Care diagnostics systems is driving the development of supporting components for microfluidic regulation. Optimally the microfluidic regulation components would operate cyclically with a minimum input power, could be precisely controlled in specific locations, and wouldn’t require bulky external components. One potential microactuator that could satisfy these requirements is an electrically stimulated hydrogel microactuator to provide a swelling and deswelling response. A hydrogel’s temporal performance is also enhanced at reduced length scales, its fabrication is amenable to mass fabrication processes, and knowledge exists for macroscale cyclical bending. However, electrical stimulation at the microscale in a closed system would need to overcome electrolyte electrolysis effects and electrochemical reactions at electrodes. In this thesis, several aspects of an electrically stimulated hydrogel microactuator that undergoes cyclical swelling have been analyzed. Firstly, the chemical and electrical field dynamics were numerically investigated through application of a yet uninvestigated cycling polarity electrical field, which highlighted the need for increased applied electric fields, and reduced hydrogel dimensions and modulus. Secondly, the hydrogel’s dynamic mechanical properties were investigated to ascertain the straining frequency’s effect on the hydrogel’s viscoelastic state, and quantifiable moduli were identified with appropriate mechanical stiffness for microactuation. These two studies provided system design parameters to maximize performance. Thirdly, to overcome electrolysis and electrochemical reactions a dielectric layer was introduced over the electrodes. This system modification required the unprecedented use of AC frequencies for stimulation and necessitated an analysis, both analytically and experimentally, of the characteristic AC frequency needed to successfully demonstrate and maximize hydrogel microactuation. The system’s frequency-varying capacitance, impedance, and apparent power were also investigated. Lastly, the hydrogel microactuator’s operation under cyclical electrical stimulation, achieved through pulse width modification, was successfully demonstrated and investigated for up to three cycles of actuation. The system was subjected to increasing electric fields to demonstrate a maximum true strain of ~27% with response times","abstract_html":"The continuing interest in Lab-on-a-Chip technologies and Point-of-Care diagnostics systems is driving the development of supporting components for microfluidic regulation. Optimally the microfluidic regulation components would operate cyclically with a minimum input power, could be precisely controlled in specific locations, and wouldn’t require bulky external components. One potential microactuator that could satisfy these requirements is an electrically stimulated hydrogel microactuator to provide a swelling and deswelling response. A hydrogel’s temporal performance is also enhanced at reduced length scales, its fabrication is amenable to mass fabrication processes, and knowledge exists for macroscale cyclical bending. However, electrical stimulation at the microscale in a closed system would need to overcome electrolyte electrolysis effects and electrochemical reactions at electrodes. In this thesis, several aspects of an electrically stimulated hydrogel microactuator that undergoes cyclical swelling have been analyzed. Firstly, the chemical and electrical field dynamics were numerically investigated through application of a yet uninvestigated cycling polarity electrical field, which highlighted the need for increased applied electric fields, and reduced hydrogel dimensions and modulus. Secondly, the hydrogel’s dynamic mechanical properties were investigated to ascertain the straining frequency’s effect on the hydrogel’s viscoelastic state, and quantifiable moduli were identified with appropriate mechanical stiffness for microactuation. These two studies provided system design parameters to maximize performance. Thirdly, to overcome electrolysis and electrochemical reactions a dielectric layer was introduced over the electrodes. This system modification required the unprecedented use of AC frequencies for stimulation and necessitated an analysis, both analytically and experimentally, of the characteristic AC frequency needed to successfully demonstrate and maximize hydrogel microactuation. The system’s frequency-varying capacitance, impedance, and apparent power were also investigated. Lastly, the hydrogel microactuator’s operation under cyclical electrical stimulation, achieved through pulse width modification, was successfully demonstrated and investigated for up to three cycles of actuation. The system was subjected to increasing electric fields to demonstrate a maximum true strain of ~27% with response times","abstract_has_math":false,"creators":["Saunders, Joseph RC"],"institution":"University of Alberta","degree_name":"Doctor of Philosophy","degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Walied Moussa, Department of Mechanical Engineering"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-11","date_published":"2013-11","updated_at":"2026-11-26T21:01:59Z","subjects":["Hydrogels","Numerical modelling","Dielectric Barrier","MEMS","AC Frequency","Cyclical","Dynamic Mechanical Properties","Swelling","Electrical","Microactuator"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3R703","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3R703","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F97397","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F97397","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Walied Moussa, Department of Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Subir Bhattacharjee, Department of Mechanical Engineering, UofA","Ziad Saghir, Department of Mechanical and Industrial Engineering, Ryerson University","Alidad Amirfazli, Department of Mechanical Engineering, Lassonde School of Engineering","Dan Sameoto, Department of Mechanical Engineering, UofA"]},{"key":"dc:creator","label":"Author","values":["Saunders, Joseph RC"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T13:32:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T13:32:06Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Hydrogels","Numerical modelling","Dielectric Barrier","MEMS","AC Frequency","Cyclical","Dynamic Mechanical Properties","Swelling","Electrical","Microactuator"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3R703"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The continuing interest in Lab-on-a-Chip technologies and Point-of-Care diagnostics systems is driving the development of supporting components for microfluidic regulation. Optimally the microfluidic regulation components would operate cyclically with a minimum input power, could be precisely controlled in specific locations, and wouldn’t require bulky external components. One potential microactuator that could satisfy these requirements is an electrically stimulated hydrogel microactuator to provide a swelling and deswelling response. A hydrogel’s temporal performance is also enhanced at reduced length scales, its fabrication is amenable to mass fabrication processes, and knowledge exists for macroscale cyclical bending. However, electrical stimulation at the microscale in a closed system would need to overcome electrolyte electrolysis effects and electrochemical reactions at electrodes. In this thesis, several aspects of an electrically stimulated hydrogel microactuator that undergoes cyclical swelling have been analyzed. Firstly, the chemical and electrical field dynamics were numerically investigated through application of a yet uninvestigated cycling polarity electrical field, which highlighted the need for increased applied electric fields, and reduced hydrogel dimensions and modulus. Secondly, the hydrogel’s dynamic mechanical properties were investigated to ascertain the straining frequency’s effect on the hydrogel’s viscoelastic state, and quantifiable moduli were identified with appropriate mechanical stiffness for microactuation. These two studies provided system design parameters to maximize performance. Thirdly, to overcome electrolysis and electrochemical reactions a dielectric layer was introduced over the electrodes. This system modification required the unprecedented use of AC frequencies for stimulation and necessitated an analysis, both analytically and experimentally, of the characteristic AC frequency needed to successfully demonstrate and maximize hydrogel microactuation. The system’s frequency-varying capacitance, impedance, and apparent power were also investigated. Lastly, the hydrogel microactuator’s operation under cyclical electrical stimulation, achieved through pulse width modification, was successfully demonstrated and investigated for up to three cycles of actuation. The system was subjected to increasing electric fields to demonstrate a maximum true strain of ~27% with response times"]},{"key":"dc:title","label":"Title","values":["AC Frequency-based Cyclical Electrical Stimulation of Hydrogel Microactuators"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Walied Moussa, Department of Mechanical Engineering"],"dc:contributor.other":["Subir Bhattacharjee, Department of Mechanical Engineering, UofA","Ziad Saghir, Department of Mechanical and Industrial Engineering, Ryerson University","Alidad Amirfazli, Department of Mechanical Engineering, Lassonde School of Engineering","Dan Sameoto, Department of Mechanical Engineering, UofA"],"dc:creator":["Saunders, Joseph RC"],"dc:date.accessioned":["2025-05-29T13:32:06Z"],"dc:date.available":["2025-05-29T13:32:06Z"],"dc:date.issued":["2013-11"],"dc:description.abstract":["The continuing interest in Lab-on-a-Chip technologies and Point-of-Care diagnostics systems is driving the development of supporting components for microfluidic regulation. Optimally the microfluidic regulation components would operate cyclically with a minimum input power, could be precisely controlled in specific locations, and wouldn’t require bulky external components. One potential microactuator that could satisfy these requirements is an electrically stimulated hydrogel microactuator to provide a swelling and deswelling response. A hydrogel’s temporal performance is also enhanced at reduced length scales, its fabrication is amenable to mass fabrication processes, and knowledge exists for macroscale cyclical bending. However, electrical stimulation at the microscale in a closed system would need to overcome electrolyte electrolysis effects and electrochemical reactions at electrodes. In this thesis, several aspects of an electrically stimulated hydrogel microactuator that undergoes cyclical swelling have been analyzed. Firstly, the chemical and electrical field dynamics were numerically investigated through application of a yet uninvestigated cycling polarity electrical field, which highlighted the need for increased applied electric fields, and reduced hydrogel dimensions and modulus. Secondly, the hydrogel’s dynamic mechanical properties were investigated to ascertain the straining frequency’s effect on the hydrogel’s viscoelastic state, and quantifiable moduli were identified with appropriate mechanical stiffness for microactuation. These two studies provided system design parameters to maximize performance. Thirdly, to overcome electrolysis and electrochemical reactions a dielectric layer was introduced over the electrodes. This system modification required the unprecedented use of AC frequencies for stimulation and necessitated an analysis, both analytically and experimentally, of the characteristic AC frequency needed to successfully demonstrate and maximize hydrogel microactuation. The system’s frequency-varying capacitance, impedance, and apparent power were also investigated. Lastly, the hydrogel microactuator’s operation under cyclical electrical stimulation, achieved through pulse width modification, was successfully demonstrated and investigated for up to three cycles of actuation. The system was subjected to increasing electric fields to demonstrate a maximum true strain of ~27% with response times"],"dc:identifier.doi":["https://doi.org/10.7939/R3R703"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Hydrogels","Numerical modelling","Dielectric Barrier","MEMS","AC Frequency","Cyclical","Dynamic Mechanical Properties","Swelling","Electrical","Microactuator"],"dc:title":["AC Frequency-based Cyclical Electrical Stimulation of Hydrogel Microactuators"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:01:59Z"}