{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/98301"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/98301","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Analysis of Dielectric Loaded Circular Waveguide Probes for Time Domain Reflectometry","abstract":"Time domain reflectometry has been used for fluid level measurement and characterization since the 1960's, however, there is little research present in the literature to improve the measurements by using alternate probe designs. Numerical analysis of a dielectric loaded circular waveguide probe has determined that appropriately chosen dimensions and dielectric loading will allow for control of the reflection coefficient and consequently its permittivity accuracy. Additionally, the resulting reduction in signal velocity allows for an increase in height measurement accuracy. A detailed optimization procedure has been developed and implemented with MATLAB to determine the required probe dimensions and dielectric loading for a particular lossless application. Using Ansoft HFSS the validity of the lossless method was confirmed at low frequencies for lossy ethanol-water and acetic acid solutions. At 1GHz the procedure yields parameters that allow for accuracy increases on the order of 5 to 20 times that of a traditional probe.","abstract_html":"Time domain reflectometry has been used for fluid level measurement and characterization since the 1960&#x27;s, however, there is little research present in the literature to improve the measurements by using alternate probe designs. Numerical analysis of a dielectric loaded circular waveguide probe has determined that appropriately chosen dimensions and dielectric loading will allow for control of the reflection coefficient and consequently its permittivity accuracy. Additionally, the resulting reduction in signal velocity allows for an increase in height measurement accuracy. A detailed optimization procedure has been developed and implemented with MATLAB to determine the required probe dimensions and dielectric loading for a particular lossless application. Using Ansoft HFSS the validity of the lossless method was confirmed at low frequencies for lossy ethanol-water and acetic acid solutions. At 1GHz the procedure yields parameters that allow for accuracy increases on the order of 5 to 20 times that of a traditional probe.","abstract_has_math":false,"creators":["Ryziuk, Christopher B R"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":"Electromagnetics and Microwaves","degree_department":null,"school":null,"contributors":[],"advisors":["Karumudi, Rambabu (Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-06","date_published":"2014-06","updated_at":"2026-11-26T21:57:12Z","subjects":["Circular waveguide","Liquid level measurement","Radio frequency (RF)","Guided wave radar (GWR)","Permittivity measurement","Liquid characterization","Measurement accuracy","Dielectric constant","Dispersion","Dielectric loaded waveguides","Time domain reflectometry (TDR)"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3MC8RQ6P","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3MC8RQ6P","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F98301","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F98301","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Karumudi, Rambabu (Electrical and Computer Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Thundat, Thomas (Chemical and Materials Engineering)","Moez, Kambiz (Electrical and Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Ryziuk, Christopher B R"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T13:52:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T13:52:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electromagnetics and Microwaves"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Circular waveguide","Liquid level measurement","Radio frequency (RF)","Guided wave radar (GWR)","Permittivity measurement","Liquid characterization","Measurement accuracy","Dielectric constant","Dispersion","Dielectric loaded waveguides","Time domain reflectometry (TDR)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3MC8RQ6P"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Time domain reflectometry has been used for fluid level measurement and characterization since the 1960's, however, there is little research present in the literature to improve the measurements by using alternate probe designs. Numerical analysis of a dielectric loaded circular waveguide probe has determined that appropriately chosen dimensions and dielectric loading will allow for control of the reflection coefficient and consequently its permittivity accuracy. Additionally, the resulting reduction in signal velocity allows for an increase in height measurement accuracy. A detailed optimization procedure has been developed and implemented with MATLAB to determine the required probe dimensions and dielectric loading for a particular lossless application. Using Ansoft HFSS the validity of the lossless method was confirmed at low frequencies for lossy ethanol-water and acetic acid solutions. At 1GHz the procedure yields parameters that allow for accuracy increases on the order of 5 to 20 times that of a traditional probe."]},{"key":"dc:title","label":"Title","values":["Analysis of Dielectric Loaded Circular Waveguide Probes for Time Domain Reflectometry"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Karumudi, Rambabu (Electrical and Computer Engineering)"],"dc:contributor.other":["Thundat, Thomas (Chemical and Materials Engineering)","Moez, Kambiz (Electrical and Computer Engineering)"],"dc:creator":["Ryziuk, Christopher B R"],"dc:date.accessioned":["2025-05-29T13:52:49Z"],"dc:date.available":["2025-05-29T13:52:49Z"],"dc:date.issued":["2014-06"],"dc:description.abstract":["Time domain reflectometry has been used for fluid level measurement and characterization since the 1960's, however, there is little research present in the literature to improve the measurements by using alternate probe designs. Numerical analysis of a dielectric loaded circular waveguide probe has determined that appropriately chosen dimensions and dielectric loading will allow for control of the reflection coefficient and consequently its permittivity accuracy. Additionally, the resulting reduction in signal velocity allows for an increase in height measurement accuracy. A detailed optimization procedure has been developed and implemented with MATLAB to determine the required probe dimensions and dielectric loading for a particular lossless application. Using Ansoft HFSS the validity of the lossless method was confirmed at low frequencies for lossy ethanol-water and acetic acid solutions. At 1GHz the procedure yields parameters that allow for accuracy increases on the order of 5 to 20 times that of a traditional probe."],"dc:identifier.doi":["https://doi.org/10.7939/R3MC8RQ6P"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Circular waveguide","Liquid level measurement","Radio frequency (RF)","Guided wave radar (GWR)","Permittivity measurement","Liquid characterization","Measurement accuracy","Dielectric constant","Dispersion","Dielectric loaded waveguides","Time domain reflectometry (TDR)"],"dc:title":["Analysis of Dielectric Loaded Circular Waveguide Probes for Time Domain Reflectometry"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electromagnetics and Microwaves"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:57:12Z"}