{"id":{"repo_id":"alberta","oai_identifier":"oai:ualberta.scholaris.ca:123456789/98950"},"canonical_url":"https://search.ndltd.org/etd/alberta/oai:ualberta.scholaris.ca:123456789/98950","repository":{"repo_id":"alberta","name":"University of Alberta","base_url":"https://era.library.ualberta.ca/oai"},"display":{"title":"Space Vector Modulation Methods for Common-Mode Voltage Reduction in Current-Source Drives","abstract":"Various reduced common-mode voltage space vector modulation (RCMV SVM) methods have been proposed to reduce destructive common-mode voltage (CMV) in both voltage source converter (VSC) and current source converter (CSC) based motor drive systems. Most of them reduce the CMV by avoiding using zero-state vectors. Unlike CMV in VSCs which is related to constant dc-link voltage, CMV in CSCs is related to AC side voltages which vary sinusoidally. Thus, zero-state vectors in CSCs can be selected, instead of being avoided, to reduce CMV. In this thesis, three zero-state selection methods for CMV reduction in CSC based motor drives are proposed. Method 1 is CMV peak value reduction using independent approach, Method 2 is CMV peak value reduction using synchronized approach, and Method 3 is CMV average value reduction. Unlike the nonzero-state modulation methods, the proposed methods will not shrink the modulation index range or affect the harmonic performance.","abstract_html":"Various reduced common-mode voltage space vector modulation (RCMV SVM) methods have been proposed to reduce destructive common-mode voltage (CMV) in both voltage source converter (VSC) and current source converter (CSC) based motor drive systems. Most of them reduce the CMV by avoiding using zero-state vectors. Unlike CMV in VSCs which is related to constant dc-link voltage, CMV in CSCs is related to AC side voltages which vary sinusoidally. Thus, zero-state vectors in CSCs can be selected, instead of being avoided, to reduce CMV. In this thesis, three zero-state selection methods for CMV reduction in CSC based motor drives are proposed. Method 1 is CMV peak value reduction using independent approach, Method 2 is CMV peak value reduction using synchronized approach, and Method 3 is CMV average value reduction. Unlike the nonzero-state modulation methods, the proposed methods will not shrink the modulation index range or affect the harmonic performance.","abstract_has_math":false,"creators":["Shang, Jian"],"institution":"University of Alberta","degree_name":"Master of Science","degree_level":"Master's","degree_discipline":"Energy Systems","degree_department":null,"school":null,"contributors":[],"advisors":["Li, Yunwei (Department of Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-06","date_published":"2014-06","updated_at":"2026-11-26T21:18:44Z","subjects":["Current source converter","Common-mode voltage","Power electronics","Motor drive"],"languages":["en"],"rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7939/R3PM4S","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7939/R3PM4S","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aalberta%3Aoai%3Aualberta.scholaris.ca%3A123456789%2F98950","prefix":"oai_dc"},"source_record":{"url":"https://era.library.ualberta.ca/oai?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aualberta.scholaris.ca%3A123456789%2F98950","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Li, Yunwei (Department of Electrical and Computer Engineering)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Salmon, John (Department of Electrical and Computer Engineering)","Khajehoddin, Sayed Ali (Department of Electrical and Computer Engineering)","Li, Yunwei (Department of Electrical and Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Shang, Jian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-29T14:48:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-29T14:48:15Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Energy Systems"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Alberta"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Current source converter","Common-mode voltage","Power electronics","Motor drive"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7939/R3PM4S"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Various reduced common-mode voltage space vector modulation (RCMV SVM) methods have been proposed to reduce destructive common-mode voltage (CMV) in both voltage source converter (VSC) and current source converter (CSC) based motor drive systems. Most of them reduce the CMV by avoiding using zero-state vectors. Unlike CMV in VSCs which is related to constant dc-link voltage, CMV in CSCs is related to AC side voltages which vary sinusoidally. Thus, zero-state vectors in CSCs can be selected, instead of being avoided, to reduce CMV. In this thesis, three zero-state selection methods for CMV reduction in CSC based motor drives are proposed. Method 1 is CMV peak value reduction using independent approach, Method 2 is CMV peak value reduction using synchronized approach, and Method 3 is CMV average value reduction. Unlike the nonzero-state modulation methods, the proposed methods will not shrink the modulation index range or affect the harmonic performance."]},{"key":"dc:title","label":"Title","values":["Space Vector Modulation Methods for Common-Mode Voltage Reduction in Current-Source Drives"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Li, Yunwei (Department of Electrical and Computer Engineering)"],"dc:contributor.other":["Salmon, John (Department of Electrical and Computer Engineering)","Khajehoddin, Sayed Ali (Department of Electrical and Computer Engineering)","Li, Yunwei (Department of Electrical and Computer Engineering)"],"dc:creator":["Shang, Jian"],"dc:date.accessioned":["2025-05-29T14:48:15Z"],"dc:date.available":["2025-05-29T14:48:15Z"],"dc:date.issued":["2014-06"],"dc:description.abstract":["Various reduced common-mode voltage space vector modulation (RCMV SVM) methods have been proposed to reduce destructive common-mode voltage (CMV) in both voltage source converter (VSC) and current source converter (CSC) based motor drive systems. Most of them reduce the CMV by avoiding using zero-state vectors. Unlike CMV in VSCs which is related to constant dc-link voltage, CMV in CSCs is related to AC side voltages which vary sinusoidally. Thus, zero-state vectors in CSCs can be selected, instead of being avoided, to reduce CMV. In this thesis, three zero-state selection methods for CMV reduction in CSC based motor drives are proposed. Method 1 is CMV peak value reduction using independent approach, Method 2 is CMV peak value reduction using synchronized approach, and Method 3 is CMV average value reduction. Unlike the nonzero-state modulation methods, the proposed methods will not shrink the modulation index range or affect the harmonic performance."],"dc:identifier.doi":["https://doi.org/10.7939/R3PM4S"],"dc:language.iso":["en"],"dc:rights":["This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law."],"dc:subject":["Current source converter","Common-mode voltage","Power electronics","Motor drive"],"dc:title":["Space Vector Modulation Methods for Common-Mode Voltage Reduction in Current-Source Drives"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Energy Systems"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Alberta"]},"updated_at":"2026-11-26T21:18:44Z"}