{"id":{"repo_id":"arkansas","oai_identifier":"oai:scholarworks.uark.edu:etd-2185"},"canonical_url":"https://search.ndltd.org/etd/arkansas/oai:scholarworks.uark.edu:etd-2185","repository":{"repo_id":"arkansas","name":"University of Arkansas","base_url":"https://scholarworks.uark.edu/do/oai/"},"display":{"title":"Numerical Simulation of Terahertz Wave Interaction with Breast Cancer Tumor Tissue Sections","abstract":"This thesis presents numerical simulation of terahertz (THz) wave interaction with breast cancer tumor tissue sections. The obtained results are expressed in THz images of heterogeneous material that mimics the excised breast cancer tissue sections. The finite-element software package ANSYS High Frequency Structural Simulator (HFSS) was used in this work. HFSS is a full wave frequency domain three-dimensional (3D) electromagnetic simulation package. In this work, four breast cancer tissue models based on pathology images were simulated and images of the models were obtained at 1 THz. An incident Gaussian beam was raster scanned over tissue model configurations and the reflected electric fields were calculated at a grid of pixels to create the images in the far and near field zones. Several parameters that influenced the accuracy of the obtained THz images were investigated. The step size used of scanning the incident Gaussian beam over the tissue model configurations was investigated. The results showed that scanning the Gaussian beam in 100 µm steps provided better images of the tissue models compared with the 200 µm step size. The simulated tissue thicknesses of 10 µm and 40 µm were investigated here to understand the challenges faced in the THz experimental results, conducted by others in the research group. The obtained results of 40 µm thick tissue model demonstrated better differentiation of the heterogeneous regions of the tissue model compared with the 10 µm thickness, which was consistent with the trend observed in the experimental results. Additional results simulating the THz camera, i.e. using a single incident Gaussians beam that illuminates the whole tissue section without raster scanning, were investigated. All simulated THz images obtained in this work are consistent with the pathology images. The results of this work helped understand the interaction of THz waves with relatively thin sections of ex vivo breast cancer tissues.","abstract_html":"This thesis presents numerical simulation of terahertz (THz) wave interaction with breast cancer tumor tissue sections. The obtained results are expressed in THz images of heterogeneous material that mimics the excised breast cancer tissue sections. The finite-element software package ANSYS High Frequency Structural Simulator (HFSS) was used in this work. HFSS is a full wave frequency domain three-dimensional (3D) electromagnetic simulation package. In this work, four breast cancer tissue models based on pathology images were simulated and images of the models were obtained at 1 THz. An incident Gaussian beam was raster scanned over tissue model configurations and the reflected electric fields were calculated at a grid of pixels to create the images in the far and near field zones. Several parameters that influenced the accuracy of the obtained THz images were investigated. The step size used of scanning the incident Gaussian beam over the tissue model configurations was investigated. The results showed that scanning the Gaussian beam in 100 µm steps provided better images of the tissue models compared with the 200 µm step size. The simulated tissue thicknesses of 10 µm and 40 µm were investigated here to understand the challenges faced in the THz experimental results, conducted by others in the research group. The obtained results of 40 µm thick tissue model demonstrated better differentiation of the heterogeneous regions of the tissue model compared with the 10 µm thickness, which was consistent with the trend observed in the experimental results. Additional results simulating the THz camera, i.e. using a single incident Gaussians beam that illuminates the whole tissue section without raster scanning, were investigated. All simulated THz images obtained in this work are consistent with the pathology images. The results of this work helped understand the interaction of THz waves with relatively thin sections of ex vivo breast cancer tissues.","abstract_has_math":false,"creators":["Omolewu, Abayomi Omotola"],"institution":null,"degree_name":"Master of Science in Microelectronics-Photonics (MS)","degree_level":"Thesis","degree_discipline":null,"degree_department":"Microelectronics-Photonics","school":null,"contributors":["Arnold, Mark E.","Li, Baohua"],"advisors":["El-Shenawee, Magda O."],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-11-27T02:20:13Z","subjects":["Pure sciences","Applied sciences","Health and environmental sciences","Breast cancer","Electromagnets","Hfss","Numerical simulation","Terahertz image","Terahertz wave","Cancer Biology","Electromagnetics and Photonics","Medical Cell Biology"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarworks.uark.edu/etd/1186","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarworks.uark.edu/etd/1186","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aarkansas%3Aoai%3Ascholarworks.uark.edu%3Aetd-2185","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.uark.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.uark.edu%3Aetd-2185","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Arnold, Mark E.","Li, Baohua"]},{"key":"dc:contributor.advisor","label":"Advisor","values":["El-Shenawee, Magda O."]},{"key":"dc:creator","label":"Author","values":["Omolewu, Abayomi Omotola"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-09-29T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-07-01T07:00:00Z"]},{"key":"thesis:degree_department","label":"Department","values":["Microelectronics-Photonics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Microelectronics-Photonics (MS)","M.S."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Pure sciences","Applied sciences","Health and environmental sciences","Breast cancer","Electromagnets","Hfss","Numerical simulation","Terahertz image","Terahertz wave","Cancer Biology","Electromagnetics and Photonics","Medical Cell Biology"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.uark.edu/etd/1186"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents numerical simulation of terahertz (THz) wave interaction with breast cancer tumor tissue sections. The obtained results are expressed in THz images of heterogeneous material that mimics the excised breast cancer tissue sections. The finite-element software package ANSYS High Frequency Structural Simulator (HFSS) was used in this work. HFSS is a full wave frequency domain three-dimensional (3D) electromagnetic simulation package. In this work, four breast cancer tissue models based on pathology images were simulated and images of the models were obtained at 1 THz. An incident Gaussian beam was raster scanned over tissue model configurations and the reflected electric fields were calculated at a grid of pixels to create the images in the far and near field zones. Several parameters that influenced the accuracy of the obtained THz images were investigated. The step size used of scanning the incident Gaussian beam over the tissue model configurations was investigated. The results showed that scanning the Gaussian beam in 100 µm steps provided better images of the tissue models compared with the 200 µm step size. The simulated tissue thicknesses of 10 µm and 40 µm were investigated here to understand the challenges faced in the THz experimental results, conducted by others in the research group. The obtained results of 40 µm thick tissue model demonstrated better differentiation of the heterogeneous regions of the tissue model compared with the 10 µm thickness, which was consistent with the trend observed in the experimental results. Additional results simulating the THz camera, i.e. using a single incident Gaussians beam that illuminates the whole tissue section without raster scanning, were investigated. All simulated THz images obtained in this work are consistent with the pathology images. The results of this work helped understand the interaction of THz waves with relatively thin sections of ex vivo breast cancer tissues."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["Abayomi Omotola Omolewu"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["95"]},{"key":"dc:title","label":"Title","values":["Numerical Simulation of Terahertz Wave Interaction with Breast Cancer Tumor Tissue Sections"]}]}],"canonical_facts":{"dc:contributor":["Arnold, Mark E.","Li, Baohua"],"dc:contributor.advisor":["El-Shenawee, Magda O."],"dc:creator":["Omolewu, Abayomi Omotola"],"dc:date":["2015"],"dc:date.available":["2017-09-29T07:00:00Z"],"dc:date.created":["2015-07-01T07:00:00Z"],"dc:description.abstract":["This thesis presents numerical simulation of terahertz (THz) wave interaction with breast cancer tumor tissue sections. The obtained results are expressed in THz images of heterogeneous material that mimics the excised breast cancer tissue sections. The finite-element software package ANSYS High Frequency Structural Simulator (HFSS) was used in this work. HFSS is a full wave frequency domain three-dimensional (3D) electromagnetic simulation package. In this work, four breast cancer tissue models based on pathology images were simulated and images of the models were obtained at 1 THz. An incident Gaussian beam was raster scanned over tissue model configurations and the reflected electric fields were calculated at a grid of pixels to create the images in the far and near field zones. Several parameters that influenced the accuracy of the obtained THz images were investigated. The step size used of scanning the incident Gaussian beam over the tissue model configurations was investigated. The results showed that scanning the Gaussian beam in 100 µm steps provided better images of the tissue models compared with the 200 µm step size. The simulated tissue thicknesses of 10 µm and 40 µm were investigated here to understand the challenges faced in the THz experimental results, conducted by others in the research group. The obtained results of 40 µm thick tissue model demonstrated better differentiation of the heterogeneous regions of the tissue model compared with the 10 µm thickness, which was consistent with the trend observed in the experimental results. Additional results simulating the THz camera, i.e. using a single incident Gaussians beam that illuminates the whole tissue section without raster scanning, were investigated. All simulated THz images obtained in this work are consistent with the pathology images. The results of this work helped understand the interaction of THz waves with relatively thin sections of ex vivo breast cancer tissues."],"dc:description.statementofresponsibility":["Abayomi Omotola Omolewu"],"dc:format.extent":["95"],"dc:identifier":["https://scholarworks.uark.edu/etd/1186"],"dc:subject":["Pure sciences","Applied sciences","Health and environmental sciences","Breast cancer","Electromagnets","Hfss","Numerical simulation","Terahertz image","Terahertz wave","Cancer Biology","Electromagnetics and Photonics","Medical Cell Biology"],"dc:title":["Numerical Simulation of Terahertz Wave Interaction with Breast Cancer Tumor Tissue Sections"],"thesis:degree_department":["Microelectronics-Photonics"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Microelectronics-Photonics (MS)","M.S."]},"updated_at":"2026-11-27T02:20:13Z"}