{"id":{"repo_id":"arkansas","oai_identifier":"oai:scholarworks.uark.edu:etd-3030"},"canonical_url":"https://search.ndltd.org/etd/arkansas/oai:scholarworks.uark.edu:etd-3030","repository":{"repo_id":"arkansas","name":"University of Arkansas","base_url":"https://scholarworks.uark.edu/do/oai/"},"display":{"title":"Cooling Effectiveness of Modified Cold-Water Immersion Method Following Exercise-Induced Hyperthermia","abstract":"Context: Recommended treatment of exertional heat stroke (EHS) includes whole body cold-water immersion (CWI); however, remote locations, spatial or monetary restrictions challenge CWI feasibility. Thus, the development of a modified, portable CWI method would allow for optimal treatment of EHS when restrictions apply. Objective: Determine cooling efficacy of modified CWI (tarp assisted cooling with oscillation; TACO) following exertional hyperthermia. Design: Randomized, crossover controlled trial. Setting: Environmental chamber (33.4 ± 0.8°C, 55.7 ± 1.9% relative humidity). Patients or Other Participants: Sixteen (9 males, 7 females) volunteers (26 ± 4.7y, 1.76 ± 0.09m, 72.5 ± 9.0kg, 20.7 ± 7.1%body fat) with no history of compromised thermoregulation participated. Interventions: Participants completed volitional exercise (cycling or treadmill) until a rectal temperature (Tre) ≥39.0°C. Following exercise, participants transitioned to a semi-recumbent position on a tarp until Tre reached 38.1°C or until 15 minutes elapsed during both control (no immersion; CON) and TACO (immersion in 151L of 2.1 ± 0.8°C water). Main Outcome Measures: Tre, heart rate (HR), and blood pressure (reported as mean arterial pressure, MAP), were assessed pre- and post-cooling. Statistical analyses included repeated measures ANOVA with appropriate post-hoc t-tests and Bonferroni correction. Results: Tre prior to cooling was not different between conditions (CON: 39.27 ± 0.26°C, CWI: 39.30 ± 0.39°C; P=0.62; ES=-0.09) whilst post-cooling Tre was decreased in TACO (38.10 ± 0.16°C) compared to CON (38.74 ± 0.38°C, t15=-8.84;P","abstract_html":"Context: Recommended treatment of exertional heat stroke (EHS) includes whole body cold-water immersion (CWI); however, remote locations, spatial or monetary restrictions challenge CWI feasibility. Thus, the development of a modified, portable CWI method would allow for optimal treatment of EHS when restrictions apply. Objective: Determine cooling efficacy of modified CWI (tarp assisted cooling with oscillation; TACO) following exertional hyperthermia. Design: Randomized, crossover controlled trial. Setting: Environmental chamber (33.4 ± 0.8°C, 55.7 ± 1.9% relative humidity). Patients or Other Participants: Sixteen (9 males, 7 females) volunteers (26 ± 4.7y, 1.76 ± 0.09m, 72.5 ± 9.0kg, 20.7 ± 7.1%body fat) with no history of compromised thermoregulation participated. Interventions: Participants completed volitional exercise (cycling or treadmill) until a rectal temperature (Tre) ≥39.0°C. Following exercise, participants transitioned to a semi-recumbent position on a tarp until Tre reached 38.1°C or until 15 minutes elapsed during both control (no immersion; CON) and TACO (immersion in 151L of 2.1 ± 0.8°C water). Main Outcome Measures: Tre, heart rate (HR), and blood pressure (reported as mean arterial pressure, MAP), were assessed pre- and post-cooling. Statistical analyses included repeated measures ANOVA with appropriate post-hoc t-tests and Bonferroni correction. Results: Tre prior to cooling was not different between conditions (CON: 39.27 ± 0.26°C, CWI: 39.30 ± 0.39°C; P=0.62; ES=-0.09) whilst post-cooling Tre was decreased in TACO (38.10 ± 0.16°C) compared to CON (38.74 ± 0.38°C, t15=-8.84;P","abstract_has_math":false,"creators":["Luhring, Katherine Elizabeth"],"institution":null,"degree_name":"Master of Athletic Training (MAT)","degree_level":"Thesis","degree_discipline":null,"degree_department":"Health, Human Performance and Recreation","school":null,"contributors":["Bonacci, Jeffrey A.","Ganio, Matthew S."],"advisors":["McDermott, Brendon P."],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-27T02:20:31Z","subjects":["Health and environmental sciences","Exertional heat stroke","Heat illness","Heat strain","Tarp-assisted cooling","Sports Medicine"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarworks.uark.edu/etd/1491","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarworks.uark.edu/etd/1491","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aarkansas%3Aoai%3Ascholarworks.uark.edu%3Aetd-3030","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.uark.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.uark.edu%3Aetd-3030","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Bonacci, Jeffrey A.","Ganio, Matthew S."]},{"key":"dc:contributor.advisor","label":"Advisor","values":["McDermott, Brendon P."]},{"key":"dc:creator","label":"Author","values":["Luhring, Katherine Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-09-29T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-05-01T07:00:00Z"]},{"key":"thesis:degree_department","label":"Department","values":["Health, Human Performance and Recreation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Athletic Training (MAT)","M.A.T."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Health and environmental sciences","Exertional heat stroke","Heat illness","Heat strain","Tarp-assisted cooling","Sports Medicine"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.uark.edu/etd/1491"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Context: Recommended treatment of exertional heat stroke (EHS) includes whole body cold-water immersion (CWI); however, remote locations, spatial or monetary restrictions challenge CWI feasibility. Thus, the development of a modified, portable CWI method would allow for optimal treatment of EHS when restrictions apply. Objective: Determine cooling efficacy of modified CWI (tarp assisted cooling with oscillation; TACO) following exertional hyperthermia. Design: Randomized, crossover controlled trial. Setting: Environmental chamber (33.4 ± 0.8°C, 55.7 ± 1.9% relative humidity). Patients or Other Participants: Sixteen (9 males, 7 females) volunteers (26 ± 4.7y, 1.76 ± 0.09m, 72.5 ± 9.0kg, 20.7 ± 7.1%body fat) with no history of compromised thermoregulation participated. Interventions: Participants completed volitional exercise (cycling or treadmill) until a rectal temperature (Tre) ≥39.0°C. Following exercise, participants transitioned to a semi-recumbent position on a tarp until Tre reached 38.1°C or until 15 minutes elapsed during both control (no immersion; CON) and TACO (immersion in 151L of 2.1 ± 0.8°C water). Main Outcome Measures: Tre, heart rate (HR), and blood pressure (reported as mean arterial pressure, MAP), were assessed pre- and post-cooling. Statistical analyses included repeated measures ANOVA with appropriate post-hoc t-tests and Bonferroni correction. Results: Tre prior to cooling was not different between conditions (CON: 39.27 ± 0.26°C, CWI: 39.30 ± 0.39°C; P=0.62; ES=-0.09) whilst post-cooling Tre was decreased in TACO (38.10 ± 0.16°C) compared to CON (38.74 ± 0.38°C, t15=-8.84;P"]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["Katherine Luhring"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["44"]},{"key":"dc:title","label":"Title","values":["Cooling Effectiveness of Modified Cold-Water Immersion Method Following Exercise-Induced Hyperthermia"]}]}],"canonical_facts":{"dc:contributor":["Bonacci, Jeffrey A.","Ganio, Matthew S."],"dc:contributor.advisor":["McDermott, Brendon P."],"dc:creator":["Luhring, Katherine Elizabeth"],"dc:date":["2016"],"dc:date.available":["2017-09-29T07:00:00Z"],"dc:date.created":["2016-05-01T07:00:00Z"],"dc:description.abstract":["Context: Recommended treatment of exertional heat stroke (EHS) includes whole body cold-water immersion (CWI); however, remote locations, spatial or monetary restrictions challenge CWI feasibility. Thus, the development of a modified, portable CWI method would allow for optimal treatment of EHS when restrictions apply. Objective: Determine cooling efficacy of modified CWI (tarp assisted cooling with oscillation; TACO) following exertional hyperthermia. Design: Randomized, crossover controlled trial. Setting: Environmental chamber (33.4 ± 0.8°C, 55.7 ± 1.9% relative humidity). Patients or Other Participants: Sixteen (9 males, 7 females) volunteers (26 ± 4.7y, 1.76 ± 0.09m, 72.5 ± 9.0kg, 20.7 ± 7.1%body fat) with no history of compromised thermoregulation participated. Interventions: Participants completed volitional exercise (cycling or treadmill) until a rectal temperature (Tre) ≥39.0°C. Following exercise, participants transitioned to a semi-recumbent position on a tarp until Tre reached 38.1°C or until 15 minutes elapsed during both control (no immersion; CON) and TACO (immersion in 151L of 2.1 ± 0.8°C water). Main Outcome Measures: Tre, heart rate (HR), and blood pressure (reported as mean arterial pressure, MAP), were assessed pre- and post-cooling. Statistical analyses included repeated measures ANOVA with appropriate post-hoc t-tests and Bonferroni correction. Results: Tre prior to cooling was not different between conditions (CON: 39.27 ± 0.26°C, CWI: 39.30 ± 0.39°C; P=0.62; ES=-0.09) whilst post-cooling Tre was decreased in TACO (38.10 ± 0.16°C) compared to CON (38.74 ± 0.38°C, t15=-8.84;P"],"dc:description.statementofresponsibility":["Katherine Luhring"],"dc:format.extent":["44"],"dc:identifier":["https://scholarworks.uark.edu/etd/1491"],"dc:subject":["Health and environmental sciences","Exertional heat stroke","Heat illness","Heat strain","Tarp-assisted cooling","Sports Medicine"],"dc:title":["Cooling Effectiveness of Modified Cold-Water Immersion Method Following Exercise-Induced Hyperthermia"],"thesis:degree_department":["Health, Human Performance and Recreation"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Athletic Training (MAT)","M.A.T."]},"updated_at":"2026-11-27T02:20:31Z"}