{"id":{"repo_id":"arkansas","oai_identifier":"oai:scholarworks.uark.edu:etd-4017"},"canonical_url":"https://search.ndltd.org/etd/arkansas/oai:scholarworks.uark.edu:etd-4017","repository":{"repo_id":"arkansas","name":"University of Arkansas","base_url":"https://scholarworks.uark.edu/do/oai/"},"display":{"title":"Effects of Filtration Conditions on Clearance of Bacteriophage","abstract":"Virus Clearance is one of the major challenges in biopharmaceutical industry, especially in the manufacturing of drugs. U.S. Food and Drug Administration (FDA) recommends using several model bacteriophages as surrogates of pathogenic mammalian virus for process validation. In this work, two bacteriophages were tested against 30 kDa, 100 kDa, 300 kDa polyethersulfone (PES) membranes to investigate the effects of pore size on virus clearance. Virus particles were spiked into the protein feed solutions containing bovine serum albumin (BSA) or lysozyme at different concentrations. Besides protein concentration, the effects of feed pH on the filtration performance and virus rejection were also investigated.The results indicate that 100 kDa PES membrane can remove 4 logs of virus from the feed stream with and without protein while maintaining a moderate flux performance. pH does not appear to significantly affect the virus rejection. However, flux is somewhat higher when the pH of the feed is close to neutral. These results indicate that electrostatic interaction between the protein, virus particle and the membrane has a strong effect on flux and virus rejection.","abstract_html":"Virus Clearance is one of the major challenges in biopharmaceutical industry, especially in the manufacturing of drugs. U.S. Food and Drug Administration (FDA) recommends using several model bacteriophages as surrogates of pathogenic mammalian virus for process validation. In this work, two bacteriophages were tested against 30 kDa, 100 kDa, 300 kDa polyethersulfone (PES) membranes to investigate the effects of pore size on virus clearance. Virus particles were spiked into the protein feed solutions containing bovine serum albumin (BSA) or lysozyme at different concentrations. Besides protein concentration, the effects of feed pH on the filtration performance and virus rejection were also investigated.The results indicate that 100 kDa PES membrane can remove 4 logs of virus from the feed stream with and without protein while maintaining a moderate flux performance. pH does not appear to significantly affect the virus rejection. However, flux is somewhat higher when the pH of the feed is close to neutral. These results indicate that electrostatic interaction between the protein, virus particle and the membrane has a strong effect on flux and virus rejection.","abstract_has_math":false,"creators":["Te, Rigen"],"institution":null,"degree_name":"Master of Science in Biomedical Engineering (MSBME)","degree_level":"Thesis","degree_discipline":null,"degree_department":"Biomedical Engineering","school":null,"contributors":["Wickramasinghe, S. Ranil","Muldoon, Timothy J."],"advisors":["Qian, Xianghong"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-27T02:20:31Z","subjects":["Bacteriophage","Downstream process","Virus filtration","Biochemical and Biomolecular Engineering","Biomedical Engineering and Bioengineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarworks.uark.edu/etd/2477","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarworks.uark.edu/etd/2477","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aarkansas%3Aoai%3Ascholarworks.uark.edu%3Aetd-4017","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.uark.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.uark.edu%3Aetd-4017","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Wickramasinghe, S. Ranil","Muldoon, Timothy J."]},{"key":"dc:contributor.advisor","label":"Advisor","values":["Qian, Xianghong"]},{"key":"dc:creator","label":"Author","values":["Te, Rigen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-02-06T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-08-01T07:00:00Z"]},{"key":"thesis:degree_department","label":"Department","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering (MSBME)","M.S.B.M.E."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bacteriophage","Downstream process","Virus filtration","Biochemical and Biomolecular Engineering","Biomedical Engineering and Bioengineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.uark.edu/etd/2477"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Virus Clearance is one of the major challenges in biopharmaceutical industry, especially in the manufacturing of drugs. U.S. Food and Drug Administration (FDA) recommends using several model bacteriophages as surrogates of pathogenic mammalian virus for process validation. In this work, two bacteriophages were tested against 30 kDa, 100 kDa, 300 kDa polyethersulfone (PES) membranes to investigate the effects of pore size on virus clearance. Virus particles were spiked into the protein feed solutions containing bovine serum albumin (BSA) or lysozyme at different concentrations. Besides protein concentration, the effects of feed pH on the filtration performance and virus rejection were also investigated.The results indicate that 100 kDa PES membrane can remove 4 logs of virus from the feed stream with and without protein while maintaining a moderate flux performance. pH does not appear to significantly affect the virus rejection. However, flux is somewhat higher when the pH of the feed is close to neutral. These results indicate that electrostatic interaction between the protein, virus particle and the membrane has a strong effect on flux and virus rejection."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["Rigen Te"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["35"]},{"key":"dc:title","label":"Title","values":["Effects of Filtration Conditions on Clearance of Bacteriophage"]}]}],"canonical_facts":{"dc:contributor":["Wickramasinghe, S. Ranil","Muldoon, Timothy J."],"dc:contributor.advisor":["Qian, Xianghong"],"dc:creator":["Te, Rigen"],"dc:date":["2017"],"dc:date.available":["2024-02-06T08:00:00Z"],"dc:date.created":["2017-08-01T07:00:00Z"],"dc:description.abstract":["Virus Clearance is one of the major challenges in biopharmaceutical industry, especially in the manufacturing of drugs. U.S. Food and Drug Administration (FDA) recommends using several model bacteriophages as surrogates of pathogenic mammalian virus for process validation. In this work, two bacteriophages were tested against 30 kDa, 100 kDa, 300 kDa polyethersulfone (PES) membranes to investigate the effects of pore size on virus clearance. Virus particles were spiked into the protein feed solutions containing bovine serum albumin (BSA) or lysozyme at different concentrations. Besides protein concentration, the effects of feed pH on the filtration performance and virus rejection were also investigated.The results indicate that 100 kDa PES membrane can remove 4 logs of virus from the feed stream with and without protein while maintaining a moderate flux performance. pH does not appear to significantly affect the virus rejection. However, flux is somewhat higher when the pH of the feed is close to neutral. These results indicate that electrostatic interaction between the protein, virus particle and the membrane has a strong effect on flux and virus rejection."],"dc:description.statementofresponsibility":["Rigen Te"],"dc:format.extent":["35"],"dc:identifier":["https://scholarworks.uark.edu/etd/2477"],"dc:subject":["Bacteriophage","Downstream process","Virus filtration","Biochemical and Biomolecular Engineering","Biomedical Engineering and Bioengineering"],"dc:title":["Effects of Filtration Conditions on Clearance of Bacteriophage"],"thesis:degree_department":["Biomedical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Biomedical Engineering (MSBME)","M.S.B.M.E."]},"updated_at":"2026-11-27T02:20:31Z"}