{"id":{"repo_id":"arkansas","oai_identifier":"oai:scholarworks.uark.edu:etd-4157"},"canonical_url":"https://search.ndltd.org/etd/arkansas/oai:scholarworks.uark.edu:etd-4157","repository":{"repo_id":"arkansas","name":"University of Arkansas","base_url":"https://scholarworks.uark.edu/do/oai/"},"display":{"title":"Systematic Review for Water Network Failure Models and Cases","abstract":"As estimated in the American Society of Civil Engineers 2017 report, in the United States, there are approximately 240,000 water main pipe breaks each year. To help estimate pipe breaks and maintenance frequency, a number of physically-based and statistically-based water main failure prediction models have been developed in the last 30 years. Precious review papers focused more on the evolution of failure models rather than modeling results. However, the modeling results of different models applied in case studies are worth reviewing as well. In this review, we focus on research papers after Year 2008 and collect latest cases without repetition. A total of 64 papers are qualified following the selection criteria. Detailed information on models and cases are summarized and compared. Chapter 2 provides a summary and review of failure models and discusses the limitation of current models. Chapter 3 provides a comprehensive review of collected cases, which include network characteristics and factors. Chapter 4 focuses on the main findings from collected papers. We conclude with insights and suggestions for future model selection for pipe failure analysis.","abstract_html":"As estimated in the American Society of Civil Engineers 2017 report, in the United States, there are approximately 240,000 water main pipe breaks each year. To help estimate pipe breaks and maintenance frequency, a number of physically-based and statistically-based water main failure prediction models have been developed in the last 30 years. Precious review papers focused more on the evolution of failure models rather than modeling results. However, the modeling results of different models applied in case studies are worth reviewing as well. In this review, we focus on research papers after Year 2008 and collect latest cases without repetition. A total of 64 papers are qualified following the selection criteria. Detailed information on models and cases are summarized and compared. Chapter 2 provides a summary and review of failure models and discusses the limitation of current models. Chapter 3 provides a comprehensive review of collected cases, which include network characteristics and factors. Chapter 4 focuses on the main findings from collected papers. We conclude with insights and suggestions for future model selection for pipe failure analysis.","abstract_has_math":false,"creators":["Gao, Yufei"],"institution":null,"degree_name":"Master of Science in Industrial Engineering (MSIE)","degree_level":"Thesis","degree_discipline":null,"degree_department":"Industrial Engineering","school":null,"contributors":["Liao, Haitao","Rossetti, Manuel D."],"advisors":["Zhang, Shengfan"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-27T02:20:31Z","subjects":["Failure model","Review","Water network","Hydraulic Engineering","Industrial Engineering","Structural Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarworks.uark.edu/etd/2608","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarworks.uark.edu/etd/2608","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aarkansas%3Aoai%3Ascholarworks.uark.edu%3Aetd-4157","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.uark.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.uark.edu%3Aetd-4157","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Liao, Haitao","Rossetti, Manuel D."]},{"key":"dc:contributor.advisor","label":"Advisor","values":["Zhang, Shengfan"]},{"key":"dc:creator","label":"Author","values":["Gao, Yufei"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-02-06T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-12-01T08:00:00Z"]},{"key":"thesis:degree_department","label":"Department","values":["Industrial Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Industrial Engineering (MSIE)","M.S.I.E."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Failure model","Review","Water network","Hydraulic Engineering","Industrial Engineering","Structural Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.uark.edu/etd/2608"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["As estimated in the American Society of Civil Engineers 2017 report, in the United States, there are approximately 240,000 water main pipe breaks each year. To help estimate pipe breaks and maintenance frequency, a number of physically-based and statistically-based water main failure prediction models have been developed in the last 30 years. Precious review papers focused more on the evolution of failure models rather than modeling results. However, the modeling results of different models applied in case studies are worth reviewing as well. In this review, we focus on research papers after Year 2008 and collect latest cases without repetition. A total of 64 papers are qualified following the selection criteria. Detailed information on models and cases are summarized and compared. Chapter 2 provides a summary and review of failure models and discusses the limitation of current models. Chapter 3 provides a comprehensive review of collected cases, which include network characteristics and factors. Chapter 4 focuses on the main findings from collected papers. We conclude with insights and suggestions for future model selection for pipe failure analysis."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["Yufei Gao"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["63"]},{"key":"dc:title","label":"Title","values":["Systematic Review for Water Network Failure Models and Cases"]}]}],"canonical_facts":{"dc:contributor":["Liao, Haitao","Rossetti, Manuel D."],"dc:contributor.advisor":["Zhang, Shengfan"],"dc:creator":["Gao, Yufei"],"dc:date":["2017"],"dc:date.available":["2024-02-06T08:00:00Z"],"dc:date.created":["2017-12-01T08:00:00Z"],"dc:description.abstract":["As estimated in the American Society of Civil Engineers 2017 report, in the United States, there are approximately 240,000 water main pipe breaks each year. To help estimate pipe breaks and maintenance frequency, a number of physically-based and statistically-based water main failure prediction models have been developed in the last 30 years. Precious review papers focused more on the evolution of failure models rather than modeling results. However, the modeling results of different models applied in case studies are worth reviewing as well. In this review, we focus on research papers after Year 2008 and collect latest cases without repetition. A total of 64 papers are qualified following the selection criteria. Detailed information on models and cases are summarized and compared. Chapter 2 provides a summary and review of failure models and discusses the limitation of current models. Chapter 3 provides a comprehensive review of collected cases, which include network characteristics and factors. Chapter 4 focuses on the main findings from collected papers. We conclude with insights and suggestions for future model selection for pipe failure analysis."],"dc:description.statementofresponsibility":["Yufei Gao"],"dc:format.extent":["63"],"dc:identifier":["https://scholarworks.uark.edu/etd/2608"],"dc:subject":["Failure model","Review","Water network","Hydraulic Engineering","Industrial Engineering","Structural Engineering"],"dc:title":["Systematic Review for Water Network Failure Models and Cases"],"thesis:degree_department":["Industrial Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Industrial Engineering (MSIE)","M.S.I.E."]},"updated_at":"2026-11-27T02:20:31Z"}