{"id":{"repo_id":"arkansas","oai_identifier":"oai:scholarworks.uark.edu:etd-4866"},"canonical_url":"https://search.ndltd.org/etd/arkansas/oai:scholarworks.uark.edu:etd-4866","repository":{"repo_id":"arkansas","name":"University of Arkansas","base_url":"https://scholarworks.uark.edu/do/oai/"},"display":{"title":"Five-Level Flying Capacitor Converter used as a Static Compensator for Current Unbalances in Three-Phase Distribution Systems","abstract":"This thesis presents and evaluates a solution for unbalanced current loading in three-phase distribution systems. The proposed solution uses the flying capacitor multilevel converter as its main topology for an application known as Unbalanced Current Static Compensator. The fundamental theory, controller design and prototype construction will be presented along with the experimental results. The Unbalanced Current Static Compensator main objective is the balancing of the up-stream currents from the installation point to eliminate the negative- and zero-sequence currents originated by unbalanced single-phase loads. Three separate single-phase flying capacitor converters are controlled independently using a d-q rotating reference frame algorithm to allow easier compensation of reactive power. Simulations of the system were developed in MATLAB/SIMULINK™ in order to validate the design parameters; then, testing of the UCSC prototype was performed to confirm the control algorithm functionality. Finally, experimental result are presented and analyzed.","abstract_html":"This thesis presents and evaluates a solution for unbalanced current loading in three-phase distribution systems. The proposed solution uses the flying capacitor multilevel converter as its main topology for an application known as Unbalanced Current Static Compensator. The fundamental theory, controller design and prototype construction will be presented along with the experimental results. The Unbalanced Current Static Compensator main objective is the balancing of the up-stream currents from the installation point to eliminate the negative- and zero-sequence currents originated by unbalanced single-phase loads. Three separate single-phase flying capacitor converters are controlled independently using a d-q rotating reference frame algorithm to allow easier compensation of reactive power. Simulations of the system were developed in MATLAB/SIMULINK™ in order to validate the design parameters; then, testing of the UCSC prototype was performed to confirm the control algorithm functionality. Finally, experimental result are presented and analyzed.","abstract_has_math":false,"creators":["Franceschi, Rafael"],"institution":null,"degree_name":"Master of Science in Electrical Engineering (MSEE)","degree_level":"Thesis","degree_discipline":null,"degree_department":"Electrical Engineering","school":null,"contributors":["Zhao, Yue","McCann, Roy A."],"advisors":["Balda, Juan C."],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-27T02:20:13Z","subjects":["distributed generation","D-FACTS","Static Compensators","Unbalanced Currents","Electronic Devices and Semiconductor Manufacturing","Power and Energy"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarworks.uark.edu/etd/3316","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarworks.uark.edu/etd/3316","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aarkansas%3Aoai%3Ascholarworks.uark.edu%3Aetd-4866","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.uark.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.uark.edu%3Aetd-4866","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Zhao, Yue","McCann, Roy A."]},{"key":"dc:contributor.advisor","label":"Advisor","values":["Balda, Juan C."]},{"key":"dc:creator","label":"Author","values":["Franceschi, Rafael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-02-06T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-08-01T07:00:00Z"]},{"key":"thesis:degree_department","label":"Department","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering (MSEE)","M.S.E.E."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["distributed generation","D-FACTS","Static Compensators","Unbalanced Currents","Electronic Devices and Semiconductor Manufacturing","Power and Energy"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.uark.edu/etd/3316"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents and evaluates a solution for unbalanced current loading in three-phase distribution systems. The proposed solution uses the flying capacitor multilevel converter as its main topology for an application known as Unbalanced Current Static Compensator. The fundamental theory, controller design and prototype construction will be presented along with the experimental results. The Unbalanced Current Static Compensator main objective is the balancing of the up-stream currents from the installation point to eliminate the negative- and zero-sequence currents originated by unbalanced single-phase loads. Three separate single-phase flying capacitor converters are controlled independently using a d-q rotating reference frame algorithm to allow easier compensation of reactive power. Simulations of the system were developed in MATLAB/SIMULINK™ in order to validate the design parameters; then, testing of the UCSC prototype was performed to confirm the control algorithm functionality. Finally, experimental result are presented and analyzed."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["Rafael Franceschi"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["109"]},{"key":"dc:title","label":"Title","values":["Five-Level Flying Capacitor Converter used as a Static Compensator for Current Unbalances in Three-Phase Distribution Systems"]}]}],"canonical_facts":{"dc:contributor":["Zhao, Yue","McCann, Roy A."],"dc:contributor.advisor":["Balda, Juan C."],"dc:creator":["Franceschi, Rafael"],"dc:date":["2019"],"dc:date.available":["2024-02-06T08:00:00Z"],"dc:date.created":["2019-08-01T07:00:00Z"],"dc:description.abstract":["This thesis presents and evaluates a solution for unbalanced current loading in three-phase distribution systems. The proposed solution uses the flying capacitor multilevel converter as its main topology for an application known as Unbalanced Current Static Compensator. The fundamental theory, controller design and prototype construction will be presented along with the experimental results. The Unbalanced Current Static Compensator main objective is the balancing of the up-stream currents from the installation point to eliminate the negative- and zero-sequence currents originated by unbalanced single-phase loads. Three separate single-phase flying capacitor converters are controlled independently using a d-q rotating reference frame algorithm to allow easier compensation of reactive power. Simulations of the system were developed in MATLAB/SIMULINK™ in order to validate the design parameters; then, testing of the UCSC prototype was performed to confirm the control algorithm functionality. Finally, experimental result are presented and analyzed."],"dc:description.statementofresponsibility":["Rafael Franceschi"],"dc:format.extent":["109"],"dc:identifier":["https://scholarworks.uark.edu/etd/3316"],"dc:subject":["distributed generation","D-FACTS","Static Compensators","Unbalanced Currents","Electronic Devices and Semiconductor Manufacturing","Power and Energy"],"dc:title":["Five-Level Flying Capacitor Converter used as a Static Compensator for Current Unbalances in Three-Phase Distribution Systems"],"thesis:degree_department":["Electrical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Electrical Engineering (MSEE)","M.S.E.E."]},"updated_at":"2026-11-27T02:20:13Z"}