{"id":{"repo_id":"arkansas","oai_identifier":"oai:scholarworks.uark.edu:etd-5046"},"canonical_url":"https://search.ndltd.org/etd/arkansas/oai:scholarworks.uark.edu:etd-5046","repository":{"repo_id":"arkansas","name":"University of Arkansas","base_url":"https://scholarworks.uark.edu/do/oai/"},"display":{"title":"Development of a COMSOL Microdialysis Model, Towards Creation of Microdialysis on a Chip with Improved Geometries and Recovery","abstract":"Microdialysis (µD) sampling is a diffusion-limited sampling method that has been widely used in different biomedical fields for greater than 35 years. Device calibration for in vivo studies is difficult for current non-steady state analytes of interest correlated with both inflammatory response and microbial signaling molecules (QS); which exist in low ng/mL to pg/mL with molecular weights over a wide range of 170 Da to 70 kDa. The primary performance metric, relative recovery (RR), relating the collected sample to the extracellular space concentration varies from 10% to 60% per analyte even under controlled bench-top conditions. Innovations in microdialysis device design have not deviated or improved upon the commercially-available cylindrical geometry for over 35 years. COMSOL Multiphysics finite element method (FEM) software was used to iteratively model and refine microfluidic-based (µF) µD device designs with the primary focus on optimizing channel geometry for improved RR. The primary focus was to improve fluid to membrane perimeter (P) to fluid cross-sectional area (A) and alter the concentration boundary layer (CBL) using passive µF mixing; which are not possible to fabricate using cylindrical geometries. The current µF µD design uses a simple asymmetric linear-looped (LL) geometry optimized with a P/A of 20 vs. 16.4 for a commercial CMA 20 µD probe with an equal 10 mm length. The simulated LL µF µD achieves a 16.1% relative increase in RR vs. experimental data at a 1.0 µL/min inlet flow rate using a 10 kDa FITC-labeled dextran as the analyte. Mixing was implemented and simulated using a modified herringbone geometry (HBM) and compared to an equivalent linear channel (LC). The HBM is shown to shift the CBL and increase diffusive flux at the membrane-fluid interface resulting in a 16.9 ± 0.7% relative increase in RR for 7 flow rates ranging from 0.125 to 2.0 µL/min vs. the LC. The combination of these changes is shown to increase RR above what is currently commercially available.","abstract_html":"Microdialysis (µD) sampling is a diffusion-limited sampling method that has been widely used in different biomedical fields for greater than 35 years. Device calibration for in vivo studies is difficult for current non-steady state analytes of interest correlated with both inflammatory response and microbial signaling molecules (QS); which exist in low ng/mL to pg/mL with molecular weights over a wide range of 170 Da to 70 kDa. The primary performance metric, relative recovery (RR), relating the collected sample to the extracellular space concentration varies from 10% to 60% per analyte even under controlled bench-top conditions. Innovations in microdialysis device design have not deviated or improved upon the commercially-available cylindrical geometry for over 35 years. COMSOL Multiphysics finite element method (FEM) software was used to iteratively model and refine microfluidic-based (µF) µD device designs with the primary focus on optimizing channel geometry for improved RR. The primary focus was to improve fluid to membrane perimeter (P) to fluid cross-sectional area (A) and alter the concentration boundary layer (CBL) using passive µF mixing; which are not possible to fabricate using cylindrical geometries. The current µF µD design uses a simple asymmetric linear-looped (LL) geometry optimized with a P/A of 20 vs. 16.4 for a commercial CMA 20 µD probe with an equal 10 mm length. The simulated LL µF µD achieves a 16.1% relative increase in RR vs. experimental data at a 1.0 µL/min inlet flow rate using a 10 kDa FITC-labeled dextran as the analyte. Mixing was implemented and simulated using a modified herringbone geometry (HBM) and compared to an equivalent linear channel (LC). The HBM is shown to shift the CBL and increase diffusive flux at the membrane-fluid interface resulting in a 16.9 ± 0.7% relative increase in RR for 7 flow rates ranging from 0.125 to 2.0 µL/min vs. the LC. The combination of these changes is shown to increase RR above what is currently commercially available.","abstract_has_math":false,"creators":["Pysz, Patrick"],"institution":null,"degree_name":"Master of Science in Microelectronics-Photonics (MS)","degree_level":"Thesis","degree_discipline":null,"degree_department":"Microelectronics-Photonics","school":null,"contributors":["Wise, Rick L.","Coridan, Robert H."],"advisors":["Stenken, Julie A."],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-27T02:20:59Z","subjects":["COMSOL","Membrane Separations","Microdialysis","Microfluidics","Biochemical and Biomolecular Engineering","Biological and Chemical Physics","Biomedical","Electromagnetics and Photonics","Electronic Devices and Semiconductor Manufacturing","Fluid Dynamics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarworks.uark.edu/etd/3496","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarworks.uark.edu/etd/3496","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aarkansas%3Aoai%3Ascholarworks.uark.edu%3Aetd-5046","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.uark.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.uark.edu%3Aetd-5046","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Wise, Rick L.","Coridan, Robert H."]},{"key":"dc:contributor.advisor","label":"Advisor","values":["Stenken, Julie A."]},{"key":"dc:creator","label":"Author","values":["Pysz, Patrick"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-12-21T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-12-01T08:00:00Z"]},{"key":"thesis:degree_department","label":"Department","values":["Microelectronics-Photonics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Microelectronics-Photonics (MS)","M.S."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["COMSOL","Membrane Separations","Microdialysis","Microfluidics","Biochemical and Biomolecular Engineering","Biological and Chemical Physics","Biomedical","Electromagnetics and Photonics","Electronic Devices and Semiconductor Manufacturing","Fluid Dynamics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.uark.edu/etd/3496"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Microdialysis (µD) sampling is a diffusion-limited sampling method that has been widely used in different biomedical fields for greater than 35 years. Device calibration for in vivo studies is difficult for current non-steady state analytes of interest correlated with both inflammatory response and microbial signaling molecules (QS); which exist in low ng/mL to pg/mL with molecular weights over a wide range of 170 Da to 70 kDa. The primary performance metric, relative recovery (RR), relating the collected sample to the extracellular space concentration varies from 10% to 60% per analyte even under controlled bench-top conditions. Innovations in microdialysis device design have not deviated or improved upon the commercially-available cylindrical geometry for over 35 years. COMSOL Multiphysics finite element method (FEM) software was used to iteratively model and refine microfluidic-based (µF) µD device designs with the primary focus on optimizing channel geometry for improved RR. The primary focus was to improve fluid to membrane perimeter (P) to fluid cross-sectional area (A) and alter the concentration boundary layer (CBL) using passive µF mixing; which are not possible to fabricate using cylindrical geometries. The current µF µD design uses a simple asymmetric linear-looped (LL) geometry optimized with a P/A of 20 vs. 16.4 for a commercial CMA 20 µD probe with an equal 10 mm length. The simulated LL µF µD achieves a 16.1% relative increase in RR vs. experimental data at a 1.0 µL/min inlet flow rate using a 10 kDa FITC-labeled dextran as the analyte. Mixing was implemented and simulated using a modified herringbone geometry (HBM) and compared to an equivalent linear channel (LC). The HBM is shown to shift the CBL and increase diffusive flux at the membrane-fluid interface resulting in a 16.9 ± 0.7% relative increase in RR for 7 flow rates ranging from 0.125 to 2.0 µL/min vs. the LC. The combination of these changes is shown to increase RR above what is currently commercially available."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["Patrick Pysz"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["136"]},{"key":"dc:title","label":"Title","values":["Development of a COMSOL Microdialysis Model, Towards Creation of Microdialysis on a Chip with Improved Geometries and Recovery"]}]}],"canonical_facts":{"dc:contributor":["Wise, Rick L.","Coridan, Robert H."],"dc:contributor.advisor":["Stenken, Julie A."],"dc:creator":["Pysz, Patrick"],"dc:date":["2019"],"dc:date.available":["2020-12-21T08:00:00Z"],"dc:date.created":["2019-12-01T08:00:00Z"],"dc:description.abstract":["Microdialysis (µD) sampling is a diffusion-limited sampling method that has been widely used in different biomedical fields for greater than 35 years. Device calibration for in vivo studies is difficult for current non-steady state analytes of interest correlated with both inflammatory response and microbial signaling molecules (QS); which exist in low ng/mL to pg/mL with molecular weights over a wide range of 170 Da to 70 kDa. The primary performance metric, relative recovery (RR), relating the collected sample to the extracellular space concentration varies from 10% to 60% per analyte even under controlled bench-top conditions. Innovations in microdialysis device design have not deviated or improved upon the commercially-available cylindrical geometry for over 35 years. COMSOL Multiphysics finite element method (FEM) software was used to iteratively model and refine microfluidic-based (µF) µD device designs with the primary focus on optimizing channel geometry for improved RR. The primary focus was to improve fluid to membrane perimeter (P) to fluid cross-sectional area (A) and alter the concentration boundary layer (CBL) using passive µF mixing; which are not possible to fabricate using cylindrical geometries. The current µF µD design uses a simple asymmetric linear-looped (LL) geometry optimized with a P/A of 20 vs. 16.4 for a commercial CMA 20 µD probe with an equal 10 mm length. The simulated LL µF µD achieves a 16.1% relative increase in RR vs. experimental data at a 1.0 µL/min inlet flow rate using a 10 kDa FITC-labeled dextran as the analyte. Mixing was implemented and simulated using a modified herringbone geometry (HBM) and compared to an equivalent linear channel (LC). The HBM is shown to shift the CBL and increase diffusive flux at the membrane-fluid interface resulting in a 16.9 ± 0.7% relative increase in RR for 7 flow rates ranging from 0.125 to 2.0 µL/min vs. the LC. The combination of these changes is shown to increase RR above what is currently commercially available."],"dc:description.statementofresponsibility":["Patrick Pysz"],"dc:format.extent":["136"],"dc:identifier":["https://scholarworks.uark.edu/etd/3496"],"dc:subject":["COMSOL","Membrane Separations","Microdialysis","Microfluidics","Biochemical and Biomolecular Engineering","Biological and Chemical Physics","Biomedical","Electromagnetics and Photonics","Electronic Devices and Semiconductor Manufacturing","Fluid Dynamics"],"dc:title":["Development of a COMSOL Microdialysis Model, Towards Creation of Microdialysis on a Chip with Improved Geometries and Recovery"],"thesis:degree_department":["Microelectronics-Photonics"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Microelectronics-Photonics (MS)","M.S."]},"updated_at":"2026-11-27T02:20:59Z"}