{"id":{"repo_id":"arkansas","oai_identifier":"oai:scholarworks.uark.edu:etd-6443"},"canonical_url":"https://search.ndltd.org/etd/arkansas/oai:scholarworks.uark.edu:etd-6443","repository":{"repo_id":"arkansas","name":"University of Arkansas","base_url":"https://scholarworks.uark.edu/do/oai/"},"display":{"title":"Verification of ASTM Centrifugation Equations for Soil Suction Determination","abstract":"The unit correction constant (B) in the ASTM D6836 standard needs to be evaluated. The B-value was proposed to be 0.00548 instead of 0.00553. This apparent discrepancy led to an investigation comparing the predicted and measured suction values for high air entry (HAE) ceramic disks. A Beckman-Coulter Model J6-MI six-bay centrifuge and a WP4C Dewpoint Potentiameter were used in the testing program. HAE ceramic disks rated with bubbling pressures of 3-bar and 5-bar were used as analogue soil specimens. The HAE ceramic disks were spun in the small-scale centrifuge to apply prescribed suction amounts and then placed in the WP4C Dewpoint Potentiameter to obtain corresponding suction readings. In addition, the weight of the pore water within the HAE ceramic disks was investigated to determine the pressure equilibrium for each ceramic disk. Based on the obtained results, the measured suction values were approximately an order of magnitude greater than the predicted suction values. Three recommendations for the laboratory testing procedure are provided for future research to improve the testing system. Thus, the unit correction constant (B) of the ASTM D6836 standard may be further evaluated to refine the suction measurements.","abstract_html":"The unit correction constant (B) in the ASTM D6836 standard needs to be evaluated. The B-value was proposed to be 0.00548 instead of 0.00553. This apparent discrepancy led to an investigation comparing the predicted and measured suction values for high air entry (HAE) ceramic disks. A Beckman-Coulter Model J6-MI six-bay centrifuge and a WP4C Dewpoint Potentiameter were used in the testing program. HAE ceramic disks rated with bubbling pressures of 3-bar and 5-bar were used as analogue soil specimens. The HAE ceramic disks were spun in the small-scale centrifuge to apply prescribed suction amounts and then placed in the WP4C Dewpoint Potentiameter to obtain corresponding suction readings. In addition, the weight of the pore water within the HAE ceramic disks was investigated to determine the pressure equilibrium for each ceramic disk. Based on the obtained results, the measured suction values were approximately an order of magnitude greater than the predicted suction values. Three recommendations for the laboratory testing procedure are provided for future research to improve the testing system. Thus, the unit correction constant (B) of the ASTM D6836 standard may be further evaluated to refine the suction measurements.","abstract_has_math":false,"creators":["Miranda Pinzon, Esteban Maclein"],"institution":null,"degree_name":"Master of Science in Civil Engineering (MSCE)","degree_level":"Thesis","degree_discipline":null,"degree_department":"Civil Engineering","school":null,"contributors":["Williams, Rodney D.","Bernhardt-Barry, Michelle L."],"advisors":["Coffman, Richard A."],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-27T02:21:08Z","subjects":["Centrifuge","Soil suction determination","Soil water characteristic curve","Civil and Environmental Engineering","Civil Engineering","Engineering","Soil Science"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarworks.uark.edu/etd/4893","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarworks.uark.edu/etd/4893","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aarkansas%3Aoai%3Ascholarworks.uark.edu%3Aetd-6443","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.uark.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.uark.edu%3Aetd-6443","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Williams, Rodney D.","Bernhardt-Barry, Michelle L."]},{"key":"dc:contributor.advisor","label":"Advisor","values":["Coffman, Richard A."]},{"key":"dc:creator","label":"Author","values":["Miranda Pinzon, Esteban Maclein"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-10-16T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-08-01T07:00:00Z"]},{"key":"thesis:degree_department","label":"Department","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Civil Engineering (MSCE)","M.S.C.E."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Centrifuge","Soil suction determination","Soil water characteristic curve","Civil and Environmental Engineering","Civil Engineering","Engineering","Soil Science"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.uark.edu/etd/4893"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The unit correction constant (B) in the ASTM D6836 standard needs to be evaluated. The B-value was proposed to be 0.00548 instead of 0.00553. This apparent discrepancy led to an investigation comparing the predicted and measured suction values for high air entry (HAE) ceramic disks. A Beckman-Coulter Model J6-MI six-bay centrifuge and a WP4C Dewpoint Potentiameter were used in the testing program. HAE ceramic disks rated with bubbling pressures of 3-bar and 5-bar were used as analogue soil specimens. The HAE ceramic disks were spun in the small-scale centrifuge to apply prescribed suction amounts and then placed in the WP4C Dewpoint Potentiameter to obtain corresponding suction readings. In addition, the weight of the pore water within the HAE ceramic disks was investigated to determine the pressure equilibrium for each ceramic disk. Based on the obtained results, the measured suction values were approximately an order of magnitude greater than the predicted suction values. Three recommendations for the laboratory testing procedure are provided for future research to improve the testing system. Thus, the unit correction constant (B) of the ASTM D6836 standard may be further evaluated to refine the suction measurements."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["73"]},{"key":"dc:title","label":"Title","values":["Verification of ASTM Centrifugation Equations for Soil Suction Determination"]}]}],"canonical_facts":{"dc:contributor":["Williams, Rodney D.","Bernhardt-Barry, Michelle L."],"dc:contributor.advisor":["Coffman, Richard A."],"dc:creator":["Miranda Pinzon, Esteban Maclein"],"dc:date":["2023"],"dc:date.available":["2023-10-16T07:00:00Z"],"dc:date.created":["2023-08-01T07:00:00Z"],"dc:description.abstract":["The unit correction constant (B) in the ASTM D6836 standard needs to be evaluated. The B-value was proposed to be 0.00548 instead of 0.00553. This apparent discrepancy led to an investigation comparing the predicted and measured suction values for high air entry (HAE) ceramic disks. A Beckman-Coulter Model J6-MI six-bay centrifuge and a WP4C Dewpoint Potentiameter were used in the testing program. HAE ceramic disks rated with bubbling pressures of 3-bar and 5-bar were used as analogue soil specimens. The HAE ceramic disks were spun in the small-scale centrifuge to apply prescribed suction amounts and then placed in the WP4C Dewpoint Potentiameter to obtain corresponding suction readings. In addition, the weight of the pore water within the HAE ceramic disks was investigated to determine the pressure equilibrium for each ceramic disk. Based on the obtained results, the measured suction values were approximately an order of magnitude greater than the predicted suction values. Three recommendations for the laboratory testing procedure are provided for future research to improve the testing system. Thus, the unit correction constant (B) of the ASTM D6836 standard may be further evaluated to refine the suction measurements."],"dc:format.extent":["73"],"dc:identifier":["https://scholarworks.uark.edu/etd/4893"],"dc:subject":["Centrifuge","Soil suction determination","Soil water characteristic curve","Civil and Environmental Engineering","Civil Engineering","Engineering","Soil Science"],"dc:title":["Verification of ASTM Centrifugation Equations for Soil Suction Determination"],"thesis:degree_department":["Civil Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Civil Engineering (MSCE)","M.S.C.E."]},"updated_at":"2026-11-27T02:21:08Z"}